And welcome to the A. O. Smith family. We would like to thank you for the trust you have shown in choosing an A. O. Smith water heater. You can be sure it will live up to your expectations. Thousands of delighted users all over the world trust A. O. Smith water heaters for their families. This user guide will introduce you to your water heater. Follow the instructions carefully and look forward to enjoying long years of trouble-free service.
A. O. Smith is a company known for its innovative technologies and energy-efficient solutions. Ours are the only water heaters with the Blue Diamond® Glass Lining for the inner tank. This cutting edge technology prevents sediment and scaling, fights corrosion and extends the life of your water heater.
Our customer-centric approach manifests itself in many other ways too. If you need any information or assistance with your water heater, just call us from any phone, anywhere in the ncountry to our Customer Care No. 1800-103-2468/1860-500-2468. Or
Factory Address:
A. O. Smith India Water Products Private Limited
(formerly known as A. O. Smith India Water Heating Private Limited)
Plot 300, Phase – II, KIADB Industrial Area, Harohalli, Kanakapura Taluk,
Ramanagara District, Karnataka – 562 112, India.
CIN: U31909KA2006PTC040282
A. O. Smith India Water Products Private Limited was established in 2006. Since then, the A. O. Smith team has conducted numerous focus group studies and spent endless research hours determining what India wanted in a water heater. Backed by 75 years of proven technological advances, A. O. Smith India has created a stylish design with features demanded by the Indian consumer.
The A. O. Smith plant with manufacturing facilities spread over 76,000 sq. ft. is located on 20 acres, just outside Bengaluru, in the KIADB Industrial Area, Harohalli. The India operations is the 16th A. O. Smith manufacturing facility worldwide. In 2013, additional 150,000 sq. ft. was added in Bengaluru factory. A. O. Smith’s India plant has extensive engineering and technical resources and has the latest technologies incorporated. A. O. Smith is the first manufacturer to invest in and produce glass lined water heaters in India. Today, A. O. Smith Corporation is one of the largest water heater manufacturers in the world and is a global leader in innovative technology and energy efficient solutions.
Read Before Operation
On Receipt
It is our policy to promote safe delivery of all orders. This product shipment has been thoroughly checked, packed and quality certified before leaving our factory.
Visible Loss or Damage
If any of the goods called for on the bill of lading or express receipt are damaged or the quantity is short, do not accept them until the freight or express delivery agent makes an appropriate notation on your freight bill or receipt.
Concealed Loss or Damage
When a shipment has been delivered to you in apparent good condition, but upon opening the packaging if any loss or damage has taken place while in transit, inform the carrier’s agent / A. O. Smith representative immediately.
About this manual
This manual is a guide to good practice for operating and periodic maintenance of the A. O. Smith HSE-VAS water heater
Do not operate the water heater before reading the user manual. Please follow instructions in this manual to ensure personal safety and proper operation of this product. Always install, operate, inspect and maintain this product in accordance with all applicable standards. Please store this user manual carefully for any future reference.
Safety
Your safety and the safety of your loved ones is paramount. There are several safety related messages in this manual, which have been provided during various steps such as the installation, operation and maintenance of your HSE-VAS water heater. These messages point out potential hazards and also educate on how to reduce any potential risks. Please always read and follow all safety messages as provided in this user manual.
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation, which if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or property damage.
WARNING
DO NOT use this water heater if any part has been under water. Immediately contact a Qualified Service Technician to inspect the water heater and contact A. O. Smith Service personnel to replace any part of the control system which has been under water. Failure to follow this instruction can result in property damage, serious injury or death.
Important
These instructions have been written as a guide for the proper installation and operation of your water heater. A. O. Smith will not accept any liability where these instructions have Nnot been followed. However, for your safety and to avoid damage caused by improper installation, it is recommended that water heater must be installed by a Qualified Service Technician.
Before proceeding with the installation instructions:
Model (Vertical Wall Mounted) | HSE-VAS-015 | HSE-VAS-025 | HSE-VAS-035 | HSE-VAS-050 | |
Volume [L] | 15 | 25 | 35 | 50 | |
Power [W] | 2000 | ||||
Voltage/Frequency [V/Hz] | 230 ~/50 | ||||
Actual Stdg. Loss [kWh/24h/45°C diff.] | 0.450 | 0.540 | 0.615 | 0.724 | |
Reheating Time for 35ºC rise [in min.] | 12 | 20 | 29 | 35 | |
Temperature range [ºC] | 25-75 * | ||||
Rated water pressure | N/cm2 | 80 | |||
Water head (metres) |
80 |
||||
Inlet/Outlet connections [inch] | ½ BSP | ||||
Net Weight (kgs) | 14 | 18 | 20 | 24 |
*The maximum set temperature(75 °C) may vary ± 5 °C.
Dimensions
Model | HSE-VAS-015 | HSE-VAS-025 | HSE-VAS-035 | HSE-VAS-050 |
A [mm] | 510 | 516 | 665 | 870 |
B [mm] | 339 | 395 | 395 | 395 |
C [mm] | 100 | 100 | 100 | 100 |
D [mm] | 134 | 155 | 155 | 155 |
E [mm] | 181 | 187 | 187 | 187 |
Part | Description |
1 | Service Cover |
2 | Temperature Control Knob |
3 | Power indicator lamp |
4 | Heating indicator lamp |
5 | Anode |
6 | Cold water inlet pipe with diffuser |
7 | Hot water outlet pipe |
8 | Blue Cap |
9 | Red Cap |
10 | Thermal Cut-out |
11 | Thermostat |
12 | Heating Element |
13 | Wall Mount Bracket |
14 | Suppor t |
Blue Diamond® Glass Lining
Blue Diamond® technology increases the life of the inner tank. The lining is stronger and more corrosion resistant than any other in the industry
Glass Coated Heating Element
Scale and sediment build-up on the surface of the element can lead to premature failure. A. O. Smith Glass Coating helps to prevent scale formation and extends the life of the heating element.
Anode Rod
The tank has an anode rod which has stainless steel core that is designed to protect the tank from corrosive elements. The anode rod uses a special cathodic action to fight these elements and thus prolong the life of the water heater.
Temperature Control Knob
The temperature control knob allows you to set the temperature anywhere between 25ºC to 75ºC.
Thermal Cutout
If the water temperature exceeds the highest preset level, the thermal cut-out cuts off the power supply to assure safety.
Multi-function Safety Valve
The Multi-function safety valve is designed to automatically relieve pressure and discharge water in case the pressure overshoots the preset limits.
Note: A. O. Smith reserves the right to amend or modify the specifications and features at any time, as and when required without any prior notification.
Safety Precautions
During Installation
Do not install the water heater where there is direct sunlight or rain. It is has to be installed indoor only.
Do not install the water heater where water splashes on the water heater.
Before installing, ensure that the following tools are available:
Tools RequiredMounting the Water Heater
Wrap the threaded part of the cold water inlet pipe with Teflon tape in clockwise direction.Connect the Multi-function Safety valve to cold water inlet pipe and rotate it in clockwise direction till it get fixed.
Connect one end of the discharge tube to Figure 13 the Multi-function Safety valve and connect the other end to the drain.
Note: The Multi-function Safety valve may drip during the usage of the heater. As the water is heated, it expands and tries to flowback through the inlet pipe but is prevented by the presence of the non-return valve. Hence water may drip from the Multi-function Safety valve. Therefore a Discharge tube is given from the valve tip to a nearby drain. To avoid dripping, it is recommended to install non-return valve at a distance of atleast 40 feet away from the inlet of the water heater.
CAUTION
*Flexible Hoses to be procured by the customer, not part of standard product. ** Multi-function Safety valve comes included with the Water Heater.
CAUTION:
Operation
Filling the Water Heater Tank
Connecting to Electrical Supply
The power cord and plug are connected with Figure 16 this water heater. Find a separate socket for power plug and make sure the socket is in firm contact with the plug. Ensure that reliable earthing has been done.
CAUTION
Temperaute Conrol Knob
Switch on the water heater’s power supply. The Power indicator lamp glows.
Temperature setting
Turn the Temperature control knob clockwise for the device to commence heating and change the set temperature. The Heating indicator lamp will glow. [The set temperature increases if the Temperature control knob is turned clockwise]. Temperature can be adjusted from 25°C to maximum 75°C. Recommended to keep Temperature control knob notch position always in medium or above level.
Modes
There are two types of modes depending on the actual water temperature inside the inner tank of the water heater:
Heating mode
When the actual temperature of the water is less than the set temperature, it enters into Heating mode. The Heating indicator lamp glows as shown in (Fig. 18)Standby mode
After the water heater reaches set temperature, it will enter into the Standby mode due to thermostat cut-off and the Power indicator lamp glows and Heating indicator lamp switch off as shown in (Fig. 19)
When the temperature of the water drops by 5°C from the set temperature due to usage of water, the water heater again enters into heating mode.
Draining the Water Heater Tank
Whenever the water heater is not used for an Figure 20 extended period, unplug the unit and drain. If it is below freezing temperature, you will need to unplug the unit and drain it.
CAUTION: Please turn off the power supply to the water heater prior to draining the water heater.
The water heater may not operate as desired if used incorrectly or there is a minor cause, even though the product has no fault. In these cases, check the following issues to solve simple problems without the help from the Customer care centre. If the problem does not solve after checking the following issues, call Customer care centre.
Problems | Possible Cause(s) | Solution |
Power indicator lamp and Heating indicator lamp does not glow. | No power supply to the water heater. | Turn ON electrical switch. |
Thermostat does not shut OFF. | Thermostat is not functioning. | Call Customer care centre. |
Improper thermostat calibration. | Call Customer care centre. | |
No hot water. | Thermal Cut-out switch open. | Call Customer care centre. |
No power supply to the heater. | Check the power socket. | |
Control circuit or internal wiring error. | Call Customer care centre. | |
Water temperature is too high. | Improper thermostat calibration. | Call Customer care centre. |
Thermal Cut-out trips. | Call Customer care centre. | |
Water heats slowly. | Heating Element is not functioning. | Call Customer care centre. |
Piping connection leaks. | Connection not sealed. | Re-connect piping, using Teflon tape. |
Water leakage from product. | Leakage in tank or other parts. | Switch off power immediately and Call Customer care centre. |
Water dripping from Multi-function Safety valve during heating. | Non-return valve is installed close to the inlet of the water heater. | Install Non-return valve at a distance of atleast 40 feet from the inlet of the water heater or connect a Discharge tube from Multi-function Safety valve to nearby drain. (Refer page 8) |
Foul smell from hot water | Presence of organic matter in input water. | Provide treated water at the input. |
No usage of hot water for a long time period. | If the water heater is not used for an extended period of time, drain the water from the water heater. Ensure water is filled back before use of water heater. | |
High electrical conductivity of water due to dissolved substances in input water. | Call Customer care centre.
Anode options available for highly conductive water. |
Note: Customer Care No. 1800-103-2468/1860-500-2468.
Circuit Diagram
Product Warranty
Your A. O. Smith water heater is warranted against defects arising from faulty design, workmanship and materials for a period of 24 months from the date of the invoice, subject to the following conditions:
Jurisdiction
The courts of competent jurisdiction at Bengaluru, Karnataka shall have exclusive jurisdiction over all matters arising out of any disputes in relation to the product.
Expert Company Service – Power of 1
Warranty Card
Customer Copy to be retained by the Customer
Invoice Number: ___________________________ Dated: _________________________ Unit Serial Number: __________________________________
Model: _________________________ Capacity: ______________________ Customer’s Name and Address: ______________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ Ph: _______________ Mobile: _____________________ E-mail: ___________________
Dealer’s Stamp and Signature
Company Copy to be sent back to the Company
Invoice Number: ___________________________ Dated: _________________________ Unit Serial Number: __________________________________
Model: _________________________ Capacity: ______________________ Customer’s Name and Address: ______________________________________________ ___________________________________________________________________________ ___________________________________________________________________________ Ph: _______________ Mobile: _____________________ E-mail: ___________________ Dealer’s Stamp and Signature
For Service needs:
Please contact our A. O. Smith
Customer Care No. : 1800-103-2468/1860-500-2468.
SMS us : +91 99410 32468
E-mail us : [email protected]
Registered Office
A. O. Smith India Water Products Private Limited
(formerly known as A. O. Smith India Water Heating Private Limited) Plot 300, Phase – II, KIADB Industrial Area, Harohalli, Kanakapura Taluk, Ramanagara District, Karnataka – 562 112, India.