CHAMPION GLOBAL POWER EQUIPMENT 1200W Portable Generator
![]() |
Congratulations on your purchase of a Champion Power Equipment (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication, and we reserve the right to change, alter and/ or improve the product and this document at any time without prior notice.
Since CPE highly values how our products are designed, manufactured, operated and are serviced, and also highly value your safety and the safety of others, we would like you to take the time to review this product manual and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please always exercise common sense and always err on the side of caution when operating the product to ensure no accident, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will need to supply the complete model and serial numbers of your product. Transcribe the information found on your product’s nameplate label to the table below
The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.
![]() |
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury |
![]() |
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. |
![]() |
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury |
![]() |
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury |
![]() |
Cancer and Reproductive Harm – www.P65Warnings.ca.gov |
![]() |
Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. |
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA.
DO NOT operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined area through windows, doors, vents or other openings.
![]() |
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. |
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up according to the manufacturer’s instructions.
![]() |
Rotating parts can entangle hands, feet, hair, clothing and/ or accessories. Traumatic amputation or severe laceration can result. |
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught.
![]() |
Operation of this equipment may create sparks that can start fires around dry vegetation. |
A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements.
![]() |
Generator produces powerful voltage. |
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged or frayed. Use Champion electrical cords only for proper application.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp areas and areas containing conductive material such as metal decking.
Connection to your home’s electrical system requires a listed 30A transfer switch installed by a licensed electrician and approved by the local authority having jurisdiction. The connection must isolate the generator from the utility power and must comply with all applicable laws and electrical codes.
![]() |
Sparks can result in fire or electrical shock. |
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot contact the plug.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
![]() |
Running engines produce heat. Severe burns can occur on contact. Combustible material can catch fire on contact. |
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all sides to ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.
![]() |
Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go. Unintentional startup can result in entanglement, traumatic amputation or laceration. Broken bones, fractures, bruises or sprains could result. |
When starting engine, pull the starter cord slowly until resistance is felt and then pull rapidly to avoid kickback.
DO NOT start or stop the engine with electrical devices plugged in and turned on.
![]() |
Exceeding the generator’s running capacity can damage the generator and/or electrical devices connected to it. |
DO NOT overload the generator.
Start the generator and allow the engine to stabilize before connecting electrical loads.
Connect electrical equipment in the off position, and then turn them on for operation.
Turn electrical equipment off and disconnect before stopping the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
![]() |
Improper treatment or use of the generator can damage it, shorten its life and void your warranty. |
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and disconnect them from the generator.
DO NOT use the generator if:
– Electrical output is lost
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
![]() |
Medical and life support uses. |
In case of emergency, call 911 immediately.
NEVER use this product to power life support devices or life support appliances.
NEVER use this product to power medical devices or medical appliances.
Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live.
Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency
![]() |
GASOLINE, GASOLINE VAPORS AND PROPANE (LPG) ARE HIGHLY FLAMMABLE AND EXPLOSIVE. |
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors:
LPG:
When adding or removing gasoline:
Turn the generator off and let it cool for at least two minutes before removing the gasoline cap. Loosen the cap slowly to relieve pressure in the tank.
Only fill or drain gasoline outdoors in a well-ventilated area.
DO NOT pump gasoline directly into the generator at the gas station. Use an approved container to transfer the fuel to the generator.
DO NOT overfill the gasoline tank.
Always keep gasoline away from sparks, open flames, pilot lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.
When starting the generator:
DO NOT attempt to start a damaged generator.
Make certain that the gasoline cap, air filter, spark plug, fuel lines and exhaust system are properly in place.
Allow spilled gasoline to evaporate fully before attempting to start the engine.
Make certain that the generator is resting firmly on level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
When transporting or servicing the generator:
Make certain that the fuel valve is in the OFF position, the gasoline tank is empty.
For LPG compatible models, be sure that the LPG cylinder is disconnected and stored securely away from the generator.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and other sources of ignition.
Do not store generator, gasoline or LPG cylinders near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
![]() |
Never use a gasoline container, gasoline tank, LPG connector hose, LPG cylinder or any other fuel item that is damaged or appears damaged. |
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
SYMBOL | MEANING |
![]() |
Read Operator’s manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product. |
![]() |
Clearance. Keep all objects at least 5 feet from this machine. Heat from the muffler and exhaust gas can ignite combustible objects. |
![]() |
Ground. Consult with local electrician to determine grounding requirements before operation. |
![]() |
Electric Shock. Failure to use in dry conditions and to observe safe practices can result in electric shock. Improper connections to a building can allow current to back feed into utility lines, creating an electrocution hazard. A transfer switch must be used when connecting to a building. |
![]() |
Fire/Explosion. Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death. Operation of this equipment may create sparks that can start fires around dry vegetation. A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements. |
![]() |
hot Surface. To reduce the risk of injury or damage, avoid contact with any hot surface. |
![]() |
Open Flame alert. Fuel and its vapors are extremely flammable and explosive. Keep fuel away from smoking, open flames, sparks, pilot lights, heat, and other ignition sources. |
![]() |
Wet Conditions alert. Do not expose to rain or use in damp locations. |
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
SYMBOL | MEANING |
![]() |
Start. |
![]() |
Check Oil Level. Recommended oil is 10W-30. The engine can be seriously damaged without oil. Always check the oil level before using. The machine must be resting firmly on level ground when checking. |
![]() |
Check Fuel Level. Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of less than 10% by volume. |
![]() |
Fuel Valve ON. |
![]() |
Engine Switch ON. Press the Engine Switch to “ON” position. |
![]() |
Choke. Move choke lever to “CHOKE” position. |
![]() |
Recoil Starter. Pull recoil starter to start the engine. |
![]() |
Choke. Move choke lever to “RUN” position. |
![]() |
Plug In. Plug in desired devices. |
![]() |
Unplug. Unplug devices when turning generator off. |
![]() |
Engine Switch OFF. Press the Ignition Switch to “OFF” position. |
![]() |
Fuel Valve OFF. |
![]() |
Stop. |
![]() |
hertz. Shown on Intelligauge as “F##.#” |
![]() |
Volts. Shown on Intelligauge as “U###” |
![]() |
Runtime. Shown on Intelligauge as “###.#” |
![]() |
Engine ON |
![]() |
Engine OFF |
These labels warn you of potential hazards that can cause serious injury. Read them carefully.
If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
LABEL | DESCRIPTION | |
A | ![]() |
CO Danger |
B | ![]() |
Safety Icons |
C | ![]() |
Fuel |
D | ![]() |
Hot Surface |
E | ![]() |
Spark Arrestor |
Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
RECEPTACLES | ||
A | ![]() |
(2x) 120V AC, 20a (NEMA 5-20R) May be used to supply electrical power for operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical loads. |
Accessories | |
Oil Funnel | 1 |
Assembly Parts | |
Vibration Mounts (engine side) (A) | 2 |
Vibration Mounts (alternator side) (B) | 2 |
Flange Bolt M8 × 20 (C) | 2 |
Lock Nut M8 (D) | 4 |
Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.
If you have any questions regarding the assembly of your generator, call our Technical Support Team at 1-877-338-0999. Please have your serial number and model number available.
Attach the Engine Vibration Mounts
Attach the Alternator Vibration Mounts
![]() |
DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage to the generator as a result of failure to follow these instructions will void your warranty |
![]() |
The generator rotor has a sealed, pre-lubricated ball bearing that requires no additional lubrication for the life of the bearing. |
![]() |
The recommended oil type is 10W-30 automotive oil |
![]() |
Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. If using the dipstick to check oil level, DO NOT screw in the dipstick while checking. |
![]() |
Check oil often during the break-in period. Refer to the section for recommended service intervals |
![]() |
The engine is equipped with a low oil shut-off and will stop when the oil level in the crankcase falls below the threshold level. |
![]() |
The first 5 hours of run time are the break-in period for the unit. During the break in period stay at or below 50% of the running watt rating and vary the load occasionally to allow stator windings to heat and cool. Adjusting the load will also cause engine speed to vary and help seat piston rings. After the 5 hour break-in period, change the oil. |
![]() |
Weather will affect engine oil and engine performance. Change the type of engine oil used based on weather conditions to suit the engine needs. |
![]() |
Synthetic oil may be used after the 5 hour initial breaking period. Using synthetic oil does not increase the recommended oil change interval. Full synthetic 5W-30 oil will aid in starting in cold ambient |
![]() |
Use regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of less than 10% by volume. |
DO NOT mix oil and gasoline.
Fill tank to approximately ¼ in. (6.4 mm) below the top of the tank to allow for gasoline expansion.
DO NOT pump gasoline directly into the generator at the pump. Use an approved container to transfer the gasoline to the generator.
DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
DO NOT overfill the tank.
DO NOT light cigarettes or smoke when filling the tank.
![]() |
Pouring gasoline too fast through the fuel screen may result in blow back of gasoline at the operator while filling. |
![]() |
Our engines work well with 10% or less ethanol blend gasoline. When using ethanol-gasoline blends there are some issues worth noting:
It is advisable to always shut off the gasoline supply, run the engine to starvation and drain the tank when the equipment is not in use for more than 30 days. |
Your generator must be properly connected to an appropriate ground to help prevent electric shock
![]() |
Failure to properly ground the generator can result in electric shock. |
A ground terminal connected to the frame of the generator has been provided (see for terminal location).
For remote grounding, connect of a length of heavy gauge (12 AWG minimum) copper wire between the generator ground terminal and a copper rod driven into the ground. We strongly recommend that you consult with a qualified electrician to ensure compliance with local electrical codes.
NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some areas, generators must be registered with the local utility. Generators used at construction sites may be subject to additional rules and regulations. Generators should be on a flat, level surface at all times. (Even while not in operation) Generators must have at least 5 ft. (1.5 m) of clearance from all combustible material. In addition to clearance from all combustible material, generators must also have at least 3 ft.
(91.4 cm) of clearance on all sides to allow for adequate cooling, maintenance and servicing. Generators should never be started or operated in the back of a SUV, camper, trailer, in the bed of a truck (regular, flat or otherwise), under staircases/stairwells, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler.
DO NOT contain generators during operation. Allow generators to properly cool before transport or storage.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up in your home according to the manufacturer’s instructions.
Place the generator in a well-ventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning generator.
Failure to follow proper safety precautions may void manufacturer’s warranty
![]() |
Do not operate or store the generator in rain, snow, or wet weather. |
Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution.
![]() |
During operation the muffler and exhaust fumes produced will become hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or contained, temperatures can become extremely heated and may lead to fire. |
A ground terminal connected to the frame of the generator has been provided (see Controls and Features for terminal location).
Neutral Floating
Neutral Bonded to Frame
The generator system ground connects lower frame crossmember below the alternator. The system ground is connected to the AC neutral wire.
* See your model’s control panel for specified type of grounding
Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage range and may be affected by momentary voltage fluctuations. While there is no way to prevent voltage fluctuations, you can take steps to protect sensitive electronic equipment.
![]() |
Keep choke in “CHOKE” position for only 1 pull of the recoil starter. After first pull, move choke to the “RUN” position for up to the next 3 pulls of the recoil starter. Too much choke leads to spark plug fouling/engine flooding due to the lack of incoming air. This will cause the engine not to start. |
![]() |
For gasoline restarts with hot engine in hot ambient > 30°C (86°F), keep the choke in 75% of the “CHOKE” position for only 1 pull of the recoil starter. After first pull, move choke to the “RUN” position for up to 3 more pulls of the recoil starter. Too much choke leads to spark plug fouling/engine flooding due to the lack of incoming air. This will cause the engine not to start. |
![]() |
For gas starting in cold ambient <15°C (59°F) the choke must be in 100% of the “CHOKE” position for recoil start procedures. Do not over-choke. As soon as engine starts, gradually move the choke lever to the “RUN” position over a 2-5 second duration. |
Let the engine stabilize and warm up for a few minutes after starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC single phase, 60 Hz electrical loads.
![]() |
Connecting a generator to your electric utility company’s power lines or to another power source may be against the law. In addition, this action, if done incorrectly, could damage your generator and appliances and could cause serious injury or even death to you or a utility worker who may be working on nearby power lines. If you plan to run a portable electric generator during an outage, please notify your electric utility company immediately and remember to plug your appliances directly into the generator. Do not plug the generator into any electric outlet in your home. Doing so could create a connection to the utility company power lines. You are responsible for ensuring that your generator’s electricity does not feed back into the electric utility power lines. If the generator will be connected to a building electrical system, consult your local utility company or a qualified electrician. Connections must isolate generator power from utility power and must comply with all applicable laws and codes. |
Capacity
Follow these simple steps to calculate the running and starting watts necessary for your purposes:
Power Management
Use the following formula to convert voltage and amperage to watts:
Volts × Amps = Watts
To prolong the life of your generator and attached devices, follow these steps to add electrical load:
![]() |
Never exceed the specified capacity when adding loads to the generator. |
Important: Always ensure that the fuel valve and the engine switch are in the “OFF” position when the generator is not in use.
![]() |
If the engine will not be used for a period of two (2) weeks or longer, please see the section for proper engine and fuel storage. |
Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.
![]() |
Never operate a damaged or defective generator. |
![]() |
Improper maintenance will void your warranty. |
![]() |
Maintenance, replacement, or repair of emission control devices and systems may be performed by any non-road engine repair establishment or individual. |
The owner/operator is responsible for all periodic maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
For service or parts assistance, contact our Technical Support Team at 1-877-338-0999.
![]() |
DO NOT spray engine with water. |
Water can enter the generator through the cooling slots and damage the generator windings. It can also contaminate the fuel system.
To prevent accidental starting, remove and ground the spark plug wire before performing any service.
Change oil when the engine is warm. Refer to the oil specification to select the proper grade for your operating environment.
![]() |
Once oil has been added, a visual check should show oil about 1-2 threads from running out of the fill hole. If using the dipstick to check oil level, DO NOT screw in the dipstick while checking. |
![]() |
Failure to clean the spark arrestor will result in degraded engine performance |
![]() |
Federal and local laws and administrative requirements indicate when and where spark arrestors are required. When ordered, spark arrestors are required for operation of this generator in National Forest lands. In California, this generator must not be used on any forest-covered land, brush-covered land, or grass-covered land unless the engine is equipped with a spark arrestor. |
![]() |
Tampering with the factory set governor will void your warranty. |
The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. Contact our Technical Support Team at 1-877-338-0999 for all other service and/or adjustment needs.
Follow the service intervals indicated in the following maintenance schedule.
Service your generator more frequently when operating in adverse conditions.
Contact our Technical Support Team at 1-877-338-0999 to locate the nearest CPE certified service dealer for your generator or engine maintenance needs.
▢ Check oil level
▢ Clean around air intake and muffler
▢ Change oil
▢ Clean air filter
▢ Change oil if operating under heavy load or in hot environments
▢ Change oil
▢ Clean/adjust spark plug
▢ Check/adjust valve clearance*
▢ Clean spark arrestor
▢ Clean fuel tank and filter*
▢ Clean combustion chamber*
▢ Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service centers.
* To be performed by knowledgeable, experienced owners or CPE certified
service centers.
![]() |
Gasoline, gasoline vapors and propane (LPG) are highly flammable and extremely explosive. |
Fire or explosion can cause severe burns or death. Only fill or drain fuel outdoors in a well-ventilated area. DO NOT pump gasoline directly into the generator. Use an approved container to transfer the fuel to the generator. Never use a gasoline container, gasoline tank, LPG connector hose, LPG cylinder or any other fuel item that is damaged or appears damaged. DO NOT overfill the gasoline tank. Always keep fuel away from sparks, open flames, pilot lights, heat and other sources of ignition. DO NOT light or smoke cigarettes.
Gasoline in the gasoline tank has a maximum shelf life of up to 1 year with the addition of properly formulated fuel stabilizers and if stored in a cool, dry place. Gasoline in the carburetor, however, may gum up and clog the carburetor if it isn’t used or drained within 2-4 weeks.
For storage over 1 year, the gasoline tank and carburetor must be completely drained of gasoline.
If the generator has been improperly stored for a long period of time with gasoline in the gasoline tank and/or carburetor, all fuel must be drained and the carburetor must be thoroughly cleaned. This process involves technically advanced tasks. For assistance please call our Technical Support Team at 1-877-338-0999. If the gasoline tank and carburetor were properly emptied of all gasoline prior to the generator being stored, follow the below steps when removing from storage.
![]() |
Generator exhaust contains odorless and colorless carbon monoxide gas. |
To avoid accidental or unintended ignition of your generator during periods of storage, the following precautions should be followed:
|
Generator Model | 100403 |
Start Type | Manual |
Watts (Starting/Running) | 1500/1200 |
AC Volts | 120 |
AC Amps @ 120 (Starting/Running) | 12.5/10 |
Frequency | 60 Hz |
Phase | Single |
Gross Weight | 58.4 lb. (26.5 kg) |
Weight | 54.9 lb. (24.9 kg) |
Length | 19.3 in. (49 cm) |
Width | 14 in. (35.5 cm) |
Height | 16 in. (40.7 cm) |
Model | YF152FD-4-010 |
Displacement | 80 cc |
Type | 4-Stroke OHV |
DO NOT OVERFILL.
Type | *See chart below |
Capacity | 0.4 qt. (0.4 L) |
![]() |
Weather will affect engine oil and engine performance. Change the type of engine oil used based on weather conditions to suit the engine needs. |
Use regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of less than 10% by volume. DO NOT USE E15 or E85. DO NOT OVERFILL
Gasoline Capacity | 1.9 gal. (7 L) |
OEM Type | NHSP E6RTC |
Replacement Type | NGK BPR6HS or equivalent |
Gap | 0.028-0.031 in. (0.7-0.8 mm) |
Intake Clearance | 0.005-0.007 in. (0.13-0.17 mm) |
Exhaust Clearance | 0.007-0.009 in. (0.18-0.22 mm) |
![]() |
A technical bulletin regarding valve adjustment procedures is available at www.championpowerequipment.com. |
Starting Temperature Range (°F/°C) | 5 to 104/-15 to 40 |
![]() |
An important message about temperature: Your product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed it may be operated at temperatures ranging from 5°F (-15°C) to 122°F (50°C) for short periods of time. If exposed to temperatures outside this range during storage, it should be brought back within this range before operation. In any event, the product must always be operated outdoors, in a well-ventilated area and away from doors, windows and vents. |
# | Part Number | Description | Qty. |
1 | 12.403 | Engine, 79.8cc | 1 |
2 | 12.100001.02 | Gasket, Exhaust | 1 |
3 | 12.101000.02 | Muffler Assembly | 1 |
4 | 1.848.08 | Washer Ø8 | 2 |
5 | 1.93.08 | Lock Washer Ø8 | 2 |
6 | 1.6175.08 | Nut M8 | 2 |
7 | 46.101300.08 | Spark Arrester Assembly | 1 |
8 | 46.101503.08 | Plate, Spark Arrester | 1 |
9 | 1.9074.4.0514 | Screw/Washer Assembly M5 x 14 | 2 |
10 | 122.070400.05 | Fuel Valve | 1 |
11 | 113.070011.04 | Pipe, Fuel, 130mm | 1 |
12 | 2.06.016 | Clamp Ø8.7 x b8 | 2 |
13 | 113.070100.00 | Fuel Tank Cap | 1 |
14 | 122.070300.02 | Fuel Filter | 1 |
15 | 113.071000.09.48 | Fuel Tank, 7L, Yellow | 1 |
16 | 1.5789.0620.1 | Flange Bolt M6 x 20, Black | 4 |
17 | 1.93.06 | Lock Washer Ø6 | 5 |
18 | 2.03.004.1 | Flat Washer, Ø24 x Ø6.5 x 1.5, Black | 4 |
19 | 122.070015.01 | Mount Vibration, Fuel Tank | 4 |
20 | 113.191100.12 | Rotor Assembly, Al, Ø160 x 58mm | 1 |
21 | 113.191002.00 | Stator Cover | 1 |
22 | 113.191200.06 | Stator Assembly, Al, Ø160 x 58 mm | 1 |
23 | 2.08.148 | Flange Bolt/Washer Assembly M8 x 160 | 1 |
24 | 1.5789.0612 | Flange Bolt M6 x 12 | 2 |
25 | 12.100100.01 | Bracket, Muffler | 1 |
26 | 115.190002.00 | End Housing | 1 |
27 | 1.16674.0512.2 | Flange Bolt M5 x 12 | 3 |
28 | 2.08.073 | Flange Bolt/Washer Assembly M6 x 90 | 4 |
29 | 122.190003.00.48 | Generator End Cover, Yellow | 1 |
30 | 1.862.06 | Lock Washer Ø6, Toothed | 1 |
31 | 5.1900.081 | Grounding Line 200mm | 1 |
32 | 1.6177.1.06 | Lock Nut M6, Flange | 1 |
33 | 1.97.1.06 | Washer Ø6 | 2 |
34 | 1.62.06 | Butterfly Type Nut M6 | 1 |
35 | 61148.0.6.2 | Frame, 490 x 355 x 398 | 1 |
36 | 1.6177.1.08 | Lock Nut M8, Flange | 10 |
37 | 113.201200.00 | Motor Mount, Left | 1 |
38 | 122.201400.01 | Rubber, Support | 2 |
39 | 1.16674.0812 | Flange Bolt M8 x 12 | 2 |
40 | 113.201200.01 | Motor Mount, Right | 1 |
41 | 1.5783.0820 | Bolt M8 x 20 | 2 |
42 | 203.201400.01 | Rubber | 2 |
43 | 113.201200.02 | Motor Mount | 2 |
44 | 1.6177.1.05 | Lock Nut M5, Flange | 6 |
45 | 113.210002.07 | Control Box | 1 |
46 | 1.5789.0615.1 | Flange Bolt M6 x 15, Black | 4 |
47 | 12.061200.00.2 | Guide Plate, Rope, Black | 1 |
48 | 1.9074.4.0514.1 | Screw/Washer Assembly M5 x 14, Black | 4 |
49 | 113.200106.00 | Protector, Front Cover | 1 |
50 | 113.22.1.2 | Control Panel, Black | 1 |
51 | 5.1120.010 | Receptacle 5-20R, Duplex | 1 |
52 | 1.6177.1.04.1 | Lock Nut M4, Flange, Black | 5 |
53 | 5.1870.008 | Receptacle Cover, Receptacle 5-20R, Duplex | 1 |
54 | 5.1200.210 | 10Amp Circuit Breaker, Push Button | 1 |
55 | 5.1430.008 | Intelligauge, VFT-2 | 1 |
56 | 5.1010.003.3 | Ignition Switch, Red | 1 |
57 | 5.1860.005 | Capacitance, 11μF | 1 |
58 | 1.9074.4.0414.1 | Screw/Washer Assembly M4 x 14, Black | 1 |
59 | 122.210003.01 | Wire Jacket, Control Box | 1 |
60 | 5.1330.014 | Sheath, Wire | 1 |
61 | 122.210003.03 | Plug, End Cover | 1 |
62 | 100403.21.10 | Wire Assembly | 1 |
63 | 100403.21 | Control Panel Assembly | 1 |
# | Part Number | Description | Qty. |
1 | 12.091000.01 | Air Cleaner Assembly | 1 |
2 | 12.061000.03.48 | Recoil Assembly, Yellow | 1 |
3 | 1.16674.0612 | Flange Bolt M6 x 12 | 4 |
4 | 1.5789.0608 | Flange Bolt M6 x 8 | 3 |
5 | 12.111000.01 | Control Assembly | 1 |
6 | 12.080100.00.48 | Fan Cover, Yellow | 1 |
7 | 1.6177.2.12 | Flange Nut M12 | 1 |
8 | 12.060001.00 | Pulley Starter | 1 |
9 | 12.080001.00 | Cooling Fan | 1 |
10 | 1.16674.0620 | Flange Bolt M6 x 20 | 2 |
11 | 12.123000.02 | Ignition Coil | 1 |
12 | 15.120100.00 | Flywheel | 1 |
13 | 2.14.016 | Woodruff Key, 5 x 6.5 x 16 | 1 |
14 | 12.080014.00 | Air Guide Plate, Back | 1 |
15 | 12.080014.01 | Air Guide Plate, Front | 1 |
16 | 2.11.009 | Oil Seal Ø17 x Ø30 x 6 | 2 |
17 | 1.276.6203 | Bearing 6203 | 1 |
18 | 21.120400.00 | Diode Assembly | 1 |
19 | 1.6177.06 | Flange Nut M6 | 4 |
20 | 2.08.037 | Drain Bolt
M10 x 1.25 x 25 |
2 |
21 | 2.03.016 | Washer Ø10 x Ø16 x 1.5, Drain Bolt | 2 |
22 | 12.030100.01 | Crankcase | 1 |
23 | 12.127000.03 | Oil Level Sensor | 1 |
24 | 1.16674.0616 | Flange Bolt M6 x 16 | 2 |
25 | 2.03.020.1 | Washer Ø6.2 x Ø15 x 0.5, Black | 1 |
26 | 12.110100.00 | Gear, Governor | 1 |
27 | 12.110013.00 | Shaft, Governor Gear | 1 |
28 | 21.110011.00 | Clip, Governor Gear | 1 |
29 | 12.110012.00 | Bushing, Governor Gear | 1 |
30 | 12.050100.04 | Crankshaft | 1 |
31 | 21.040020.00 | Screw, Valve Adjustment | 2 |
32 | 21.040021.00 | Nut M6 x 0.5, Lock | 2 |
33 | 1.276.6303 | Bearing 6303 | 1 |
34 | 12.030008.01 | Gasket, Crankcase Cover | 1 |
35 | 2.04.002 | Dowel Pin Ø8 x 14 | 4 |
36 | 15.031000.00.48 | Oil Dipstick Assembly, Yellow | 1 |
37 | 15.030007.00 | Cover, Crankcase | 1 |
38 | 1.5789.0625 | Flange Bolt M6 x 25 | 6 |
39 | 12.050200.00 | Connecting Rod | 1 |
40 | 12.050005.02 | Piston | 1 |
41 | 2.09.005 | Circlip Ø16 x Ø1 | 2 |
42 | 12.050003.01 | Pin, Piston | 1 |
43 | 11.050303.00 | Ring, Oil | 1 |
44 | 11.050302.00 | Ring, Second Piston | 1 |
45 | 11.050301.00 | Ring, First Piston | 1 |
46 | 12.030009.00 | Gasket, Cylinder Head | 1 |
47 | 15.010100.00 | Cylinder Head | 1 |
48 | 2.15.005 (E6RTC) | Spark Plug E6RTC | 1 |
49 | 1.5789.0855 | Flange Bolt M8 x 55 | 4 |
50 | 21.020002.00 | Gasket, Cylinder Head Cover | 1 |
51 | 15.021000.00 | Cover, Cylinder Head | 1 |
52 | 15.020007.00 | Baffle, Wire | 1 |
53 | 15.020001.00 | Breather Tube | 1 |
54 | 2.01.010 | Stud Bolt M8 x 35 | 2 |
55 | 12.041000.02 | Camshaft | 1 |
56 | 15.040013.00 | Lifter, Valve | 2 |
57 | 15.040005.00 | Push Rod | 2 |
58 | 23.040017.00 | Oil Seal, Valve | 1 |
59 | 12.040002.00 | Valve, Intake | 1 |
60 | 12.040006.00 | Valve, Exhaust | 1 |
61 | 12.040003.00 | Spring, Valve | 2 |
62 | 12.040014.00 | Retainer, Valve Spring | 2 |
63 | 15.040004.00 | Guide Plate, Push Rod | 1 |
64 | 83.040010.01 | Bolt, Rocker Arm | 2 |
65 | 2.01.019 | Stud Bolt M6 x 89 | 2 |
66 | 12.130002.01 | Gasket, Insulator | 2 |
67 | 12.130001.00 | Insulator, Carburetor | 1 |
68 | 12.131000.01 | Carburetor | 1 |
12.131000.02 | |||
69 | 12.091100.00 | Base, Air Cleaner | 1 |
70 | 12.091001.00 | Separator, Air Cleaner | 1 |
71 | 12.091003.00 | Element, Air Cleaner | 1 |
72 | 12.091200.00 | Cover, Air Cleaner | 1 |
73 | 12.091500.00 | Bolt, Air Cleaner | 2 |
74 | 15.080300.00 | Air Guide, Upper | 1 |
75 | 12.110001.00 | Shaft, Governor Arm | 1 |
76 | 1.896.06 | Circlip Ø6 | 1 |
77 | 2.03.019 | Washer Ø8.2 x Ø17 x 0.8 | 1 |
78 | 12.110008.00 | Pin, Shaft | 1 |
79 | 12.110003.00 | Arm, Governor | 1 |
80 | 12.110007.21 | Spring, Governor | 1 |
81 | 12.110005.00 | Spring, Throttle Return | 1 |
82 | 12.110006.00 | Rod, Governor | 1 |
83 | 15.040009.00 | Rocker Arm | 2 |
84 | 1.5789.0612 | Flange Bolt M6 x 12 | 5 |
85 | 1.5789.0615 | Flange Bolt M6 x 15 | 4 |
86 | 15.010000.00 | Cylinder Head Assembly | 1 |
Problem | Cause | Solution |
Generator will not start. | No fuel. | Add fuel. |
Faulty spark plug. | Replace spark plug. | |
Unit loaded during start up. | Remove load from unit. | |
Generator will not start; Generator starts but runs roughly. | Low oil level. | Fill crankcase to the proper level. |
Place generator on a flat, level surface. | ||
Choke in the wrong position. | Adjust choke. | |
Spark plug wire loose. | Attach wire to spark plug. | |
Generator shuts down during operation. | Out of fuel. | Fill fuel tank. |
Low oil level. | Fill crankcase to the proper level. Place generator on a flat, level surface. | |
Generator cannot supply enough power or overheating. | Generator is overloaded. | Review load and adjust. See “Connecting Electrical Loads.” |
Insufficient ventilation. | Check for air restriction. Move to a well ventilated area. | |
No AC output. | Cable not properly connected. | Check all connections. |
Connected device is defective. | Replace defective device. | |
Circuit breaker is open. | Reset circuit breaker. | |
Loose wiring. | Inspect and tighten wiring connections. | |
Other. | Contact the help line. | |
Generator gallops. | Engine governor defective. | Contact the help line. |
Repeated circuit breaker tripping. | Overload. | Review load and adjust. See “Connecting Electrical Loads.” |
Faulty cords or device. | Check for damaged, bare or frayed wires. Replace defective device. |
For further technical support:
Technical Support Team
Mon-Fri 8:30 AM-5:00 PM (PST/PDT)
Toll Free 1-877-338-0999
[email protected]
CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY
Warranty Qualifications
To register your product for warranty and FREE lifetime call center technical support please visit: https://www.championpowerequipment.com/register
To complete registration you will need to include a copy of the purchase receipt as proof of original purchase. Proof of purchase is required for warranty service. Please register within ten (10) days from date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical components will be free of defects in material and workmanship for a period of three years (parts and labor) from the original date of purchase and 270 days (parts and labor) for commercial and industrial use. Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This warranty only applies to the original purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone or e-mail. If the problem is not corrected by this method, CPE will, at its option, authorize evaluation, repair or replacement of the defective part or component at a CPE Service Center. CPE will provide you with a case number for warranty service. Please keep it for future reference. Repairs or replacements without prior authorization, or at an unauthorized repair facility, will not be covered by this warranty
Warranty Exclusions
This warranty does not cover the following repairs and equipment:
Normal Wear
Products with mechanical and electrical components need periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if the product is deemed to have been misused, neglected, involved in an accident, abused, loaded beyond the product’s limits, modified, installed improperly or connected incorrectly to any electrical component. Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE.
Other Exclusions
This warranty excludes:
When applicable, this warranty does not apply to products used for prime power in place of a utility.
Limits of Implied Warranty and Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim by anyone from using this product.
THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE) ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original unit. The length of the warranty governing the exchanged unit will remain calculated by reference to the purchase date of the original unit.
This warranty gives you certain legal rights which may change from state to state or province to province. Your state or province may also have other rights you may be entitled to that are not listed within this warranty.
Contact Information
Address
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670 USA
www.championpowerequipment.com
Customer Service
Toll Free: 1-877-338-0999
[email protected]
Fax no.: 1-562-236-9429
Technical Service
Toll Free: 1-877-338-0999
[email protected]
24/7 Tech Support: 1-562-204-1188
*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency (EPA) and/or California Air Resources Board (CARB
CHAMPION POWER EQUIPMENT, INC.
(CPE) AND THE UNITED STATES ENVIRONMENT PROTECTION AGENCY (U.S. EPA)
EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with U.S. EPA emission regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA AND CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2020 small off-road engine (SORE) and engine powered equipment. New engines and equipment must be designed, built and equipped, at the time of sale, to meet U.S.
EPA regulations for small off-road engines (SORE). CPE warrants the emission control system on your small off-road engine (SORE) and equipment for the period of time listed below, provided there has been no abuse, neglect, unapproved modification, or improper maintenance of your equipment.
Your emission control system may include parts such as the carburetor, fuel injection system, the ignition system, catalytic converter and fuel lines. Also included may be hoses, belts, connectors and other emission related assemblies. Where a warrantable condition exits, CPE will repair your small off-road engine (SORE) at no cost to you including diagnosis, parts and labor.
MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:
This emission control system is warranted for two years, subject to provisions set forth below. If, during the warranty period, an emission related part on your engine is defective in materials or workmanship, the part will be repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine (SORE) owner, you are responsible for the performance of the required maintenance listed in your Owner’s Manual. CPE recommends that you retain all your receipts covering maintenance on your small off-road engine (SORE), but CPE cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.
As the small off-road engine (SORE) owner, you should however be aware that CPE may deny you warranty coverage if your small, off-road engine (SORE) or a part has failed due to abuse, neglect, improper maintenance or unapproved modifications.
You are responsible for presenting your small off-road engine (SORE) to an Authorized CPE service outlet or alternate service outlet as described in (3)(f.) below, CPE dealer or CPE, Santa Fe Springs, Ca. as soon as a problem exists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities, you should contact:
EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)
Systems covered by this warranty | Parts Description |
Fuel Metering System | Fuel regulator, Carburetor and internal parts |
Air Induction System | Air cleaner, Intake manifold |
Ignition System | Spark plug and parts, Magneto ignition system |
Exhaust System | Exhaust manifold, catalytic converter |
Miscellaneous Parts | Tubing, Fittings, Seals, Gaskets, and Clamps associated with these listed systems. |
Evaporative Emissions | Fuel Tank, Fuel Cap, Fuel Line (for liquid fuel and fuel vapors), Fuel Line Fittings, Clamps, Pressure Relief Valves, Control Valves, Control Solenoids, Electronic Controls, Vacuum Control Diaphragms, Control Cables, Control Linkages, Purge Valves, Gaskets, Vapor Hoses, Liquid/Vapor Separator, Carbon Canister, Canister Mounting Brackets, Carburetor Purge Port Connector |
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours. Alternate service locations defined in Section (3)(f.) above must be approved by CPE prior to service. Claims for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities, or to obtain warranty service, please write or call Customer Service at Champion Power Equipment, Inc.
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
[email protected]
at championpowerequipment.com
TAKEYOURGENERATOROUTSIDE.COM
or visit championpowerequipment.com