Dual Airflowsystem – Dual Filtersystem – Dual Ionizer for double air purification!
Thank you for purchasing the Clean Air Optima Intelligent Air Purifier CA 510Pro.
We wish you many years of healthy indoor air with this efficient and effective product.
Ensure that all safety precautions are followed when using this electrical appliance for the proper operation of the device. These instructions describe the safety precautions to be observed during operation. They are meant to prevent injuries and to avoid damaging the device.
Before using your new Clean Air Optima Intelligent Air Purifier CA-510Pro.
Remove the sealing from the filters first, Check down below. How to use.
The appliance consists of the following main components:
This device may only be used in accordance with this safety instructions. Take the following steps to minimize the risk of personal injury caused by for example electric shocks or fire.
(Filter installation for the front and the back)
The device needs to be positioned at least 30 cm from walls and furniture to obtain a good air flow. Make sure that the air in-and outlets are not blocked.
2 + 3 Child Lock
Child lock protects from unwanted use of the device.
The child lock is switched on / off by pressing simultaneously both Mode and Speed buttons.
The indicator light child lock will be bright.
3 + 4 Filter Reset
Reset the timer for the composite filter by pressing and holding the button Speed and Timer (for about 3 seconds). If the indicator light goes out, the timer has been successfully reset.
The digital monitor on the front side of the air purifier CA-510Pro indicates automatically and exactly current air quality by measuring the level of Particle measurement PM2.5, indoor humidity and temperature.
Particulate matter of 10um (PM10) and smaller 2,5 um (PM2.5) can get into the lungs and belongs to the top 10 threats for human health. These small particles develop through typical indoor processes such as cooking, baking, frying, smoking, as well as heating or are also transported in big quantities into indoor air because of transportation, industry, construction, biological material (pollen, bacteria, mites, and viruses), imported particles from other regains such as (airplane) exhaust gases and volcano eruptions.
Allergens such as pollen and dust cause serious and long-term health threats to millions of persons each spring: the numbers are increasing constantly.
Measurement of relative humidity and temperature
Important aspects for effective air purification: relative humidity between 45 – 60% and room temperature of about 20 – 23 °C
Cleaning the outside of the air purifier
Cleaning of the Intelligent Particle Sensor™
Clean the air quality sensor every 6 to 8 weeks.
When the value of PM 2.5 is displayed incorrectly, a cotton swab can be used to clean the sensor lens.
Attention! If the humidity in the room is very high, there is a risk of condensation on the air quality sensor. This may cause the air quality indicator (Digital Display – Particle Measurement) to indicate that the air quality is poor, while this should not be the case. In this case, we recommend that you clean the air quality sensor or do not use the air purifier in automatic mode.
The Clean Air Optima Intelligent Air Purifier CA-510Pro is equipped with a filter lifespan surveillance mechanism that signals that the filters have to be replaced after 2.000 working hours. To show that the composite filters (HEPA + Activated Carbon Filter) need to be replaced, the air purifier emits a flashing indicator light. Reset the timer for the composite filter by pressing and holding the button Speed and Timer (for about 3 seconds). If the indicator light goes out, the timer has been successfully reset.
Depending on the use, the composite filters (HEPA + Activated Carbon Filter) has a lifespan of approx. 6-8 months.
Filter cleaning
The best effect is reached by cleaning the filters once a month. If indoor air is extremely polluted, more cleaning can be required.
Clean the Pre-filter and the HEPA filter with a brush or your vacuum cleaner. That way bigger dust particles like lint, hair and dander of pets can be removed from the filter.
Warning! Do never wet or rinse the composite filters (HEPA + Activated Carbon Filter) with water.
Signs for used up filters
Increased sound, reduced air flow, congested filters, rising presence of smells. The filter needs to be replaced by a new one when the HEPA filter changes its color from white to grey or black.
If the HEPA filter remains white, there is NO need to replace the filter.
How to order filters:
Contact Clean Air Optima Customer Service tel. + 31 (0) 742670145 or visit our webshop: https://www.cleanairoptima.com/accessoires/mg/44/
The following is a troubling shooting guide to help you solve any issues that you may have using the Clean Air Optima Intelligent Air Purifier CA-510Pro.
Problem | Possible Cause | Solution |
Device does not switch on | The power cord does not connect correctly The power cord is broken The front or back panel is not installed correctly |
Connect the power plug and power socket correctly Replace the power cord Install the panel correctly. See chapter: How to use |
The air outlet smells foul | The filter traps too much odor or dust
The lifetime of the filters has expired |
Replace the composite filters Replace the composite filters |
Poor purification effect | Check if the humidity in the room is too dry The device is placed in an unventilated room or surrounded by obstacles |
Increase the humidity Remove the obstacles |
No air is blowing out of the device | The air inlet or air outlet is being blocked | Remove the obstacles |
The remote control does not work | Check if the battery is installed Check if the battery is in- stalled correctly Check the capacity of the battery Check the remote control distance exceeds the range |
Install the battery Install the battery correctly Replace the battery Range is within 5 meters from the front-side of the device |
WARNING!
If the above recommended solutions do not work, please contact Clean Air Optima technical support at the telephone number for your region. Do not attempt to disassemble, reassemble, or repair the device as this may void the warranty.
Model | CA-510Pro |
For rooms up to | 110m² / 275m³ / 1180ft² |
Rated voltage | 220V – 240V, 50Hz/60Hz |
Rated power | Max. 45W |
Fan capacity (CADR) | 468 m³/h (solid particles) – 100 m³/h (formaldehyde |
Filter performance | 99,97% |
Sterilization rate | 99.9% |
Negative ion | 2.000.000 ions/cm² |
Sound level | Silent fan < 20dB(A) Low 1 / 35dB(A) Middle 2 / 55dB(A) Turbo 3 |
Dimensions | 560 x 320 x 210mm |
Weight | 7.5kg |
Colour | Living white |
Complies with EU regulations | CE / WEEE / RoHS |
Ask your retailer or your municipality for updated information regarding the disposal of the packaging and of the device.
Date of purchase: ………………………………………………… Customers name: …………………………………………………. Address: ………………………………………………………………. Telephone: …………………………………………………………… Email: ………………………………………………………………….. Seller’s name: ……………………………………………………….. Address: ……………………………………………………………….. |
The Clean Air Optima Intelligent Air Purifier CA-510Pro is subjected to strict testing procedures before leaving the factory. If within 2 years from the date of purchase the product does not perform according to the specifications, because of factory defects, the purchaser is entitled to free repairs or replacement of parts upon presentation of this warranty (provided that the malfunction or damage to the device and/or parts occurred under normal operating conditions). What is covered: All parts defective in material and workmanship. For how long: two years from purchase date. What we will do: Repair or replace any defective parts.
Exclusions: Regular replacement filters.
Other Conditions
The provisions of this warranty are in lieu of any other written warranty whether express or implied, written or oral, including any warranty of merchantability or fitness for a particular purpose. The manufacturer’s maximum liability shall not exceed the actual purchase price paid by you for the product. In no event shall the manufacturer be liable for special, incidental, consequential, or indirect damages. This warranty does not cover a defect that has resulted from improper or unreasonable use or maintenance, faulty assembly, accident, natural catastrophes, improper packing, or unauthorized tampering, alteration, or modification as determined solely by us. This warranty is void if the label bearing the serial number has been removed or defaced.
Thank you for reading!
Share your feedback about the Clean Air Optima
Intelligent Air Purifier CA-510Pro on:
www.cleanairoptima.com
For frequently asked questions about the CA-510Pro go to:
www.cleanairoptima.com and search for the CA-510Pro.
Download PDF instruction manual on:
www.cleanairoptima.com/info/manuals
Watch all Clean Air Optima Product animation video’s on:
www.youtube.com
Clean Air Optima International B.V. | David Ricardostraat 9-7 / 9-9 | 7559 SH Hengelo (ov)
The Netherlands | Phone: +31 (0) 74 – 2670145
Clean Air Optima Germany GmbH | Enschedestraße 14 | 48529 Nordhorn | Germany
Phone: +49 (0) 5921 879-121
E-mail: [email protected] Internet: www.cleanairoptima.com
Thank you for purchasing the Clean Air Optima® Ultrasonic Humidifier CA-607W.
We wish you many years of healthy indoor air with this efficient and effective product.
These instructions describe the safety precautions to be observed during operation. They are meant to prevent injuries and to avoid damaging the device.
Description of the device
The device consists of the following main components:
Display
This device may only be used in accordance with these safety instructions. Take the following steps to minimize the risk of personal injury caused by for example electric shocks or fire.
Before getting started, remove the Clean Air Optima® CA-607W from its box and allow it to become accustomed to the room temperature for at least 30 minutes especially if the machine is cold from the outside air. Place the device on a solid, level and front water insensitive surface, approx. 60 cm from the floor and at least 20 cm from the wall.
The CA-607W is designed to operate at temperatures between 5 -40 ºC and relative humidity of less than 80%.
To get started, grasp the water tank by the handle at the top and lift from the base. Next, flip the tank over and unscrew and remove the water tank lid and filter.
Then place the water tank under the faucet for filling, grasping it from the handle under the water tank. Fill the tank with tap water (or other clean water source with water temperature under 40ºC), re-insert the lid and filter. Flip the water tank once again until it is on the right side up. Ensure that the basin is clean and then carefully place the water tank back on the lower body.
Wait a few seconds until the water tank lid starts to release water into the basin. You will hear a bubbling sound as the air enters the water tank. Plug the power plug into a suitable power outlet, a signal sounds to indicate that your device is in standby mode. If the humidifier is switched on/off, the values for temperature (margin of about 2-5 degrees difference from the room temperature) and humidity will now be displayed.
Power Button:
Press the Power Button to activate the humidifier. The machine is now operating in manual mode. It will release cool mist on a constant basis with the mist intensity level automatically set to medium.
Manual Button:
The Manual Button changes the mist level (low, medium, high). There are 3 levels of mist output available.
Child Lock:
Child lock protects from unwanted use of the device.
The Child Lock is switched on / off by pressing the Manual Button for 3 seconds.
If the child lock is switched on, a red lock icon appears in the display.
Humidity Button:
Pressing the Humidity Button, you can select the desired humidity level by pressing this button repeatedly until the required humidity level is displayed (from 40% to 80% in increments of 5%). Once you select your desired humidity level, simply stop pressing the button and your humidity level will be set.
When the humidity level in the room reaches the set humidity level, the machine will go into automatic sleep state and stop producing mist after 1 minute. When the room’s actual humidity level drops below your set humidity level, then the machine will start producing mist again.
Mode Button:
Pressing the Mode Button once, this will activate the Sleep mode, press 2 times for Auto, press 3 times for Baby, press 4 times for Health. (Sleep-Auto-Baby-Health-Sleep…..).
Sleep Mode:
When the sleep mode is activated, the display will turn off in 10 seconds. Only the sleep mode light is on.
Auto Mode:
Depending on the temperature, the humidifier sets the optimum humidity
Temperature of the air, degrees Celsius | Humidity % |
19 and lower | 65 |
20-21 | 60 |
22-23 | 55 |
24-25 | 50 |
26-27 | 45 |
28-29 | 40 |
Baby Mode:
When the Baby Mode is activated, the device turns on the function of warm mist & UV-Light and starts to achieve 55% humidity at maximum power. If the 55% humidity is achieved, then the humidification will stop. The device checks the humidity level every 10 minutes.
Health Mode:
When the Health Mode is activated, the device turns on the function of warm mist & UV-Light, it will calculates the optimal humidity and starts to achieve it at maximum power.
The optimal humidity in Health Mode is calculated as in the Auto Mode, the only difference is that the device add 5% to the result.
Example:
Optimal humidity in Auto Mode = 50%, Optimal humidity in Health Mode = 50 + 5 = 55% When the optimal humidity level is achieved, then the humidification will stop.
The device checks the accordance of the temperature level and the humidity level every 15 minutes.
Negative Ion Button:
Pressing the Negative Ion Button will activate the negative ion generator with a total capacity of > 3.000.000 negative ions / cm³ that are spread through out the entire room and thereby neutralize pollutants and smells. Negative ions attach onto dust particles, microorganisms and other unwanted particles in the air and connect them to each other. This way, the particles become heavier than air and fall onto the ground so that you can no longer breathe them in. Negative ions are most found in the forest, mountains and by the sea. Negative ions ensures fresh and healthy air.
Timer Button:
Pressing the Timer Button sets the timer. The timer function determines how many hours the humidifier will operate. You can set the timer simply by pressing it once for each hour that you would like to run the device. The timer can be set from 1 hour to 12 hours. As time passes, the time value decreases until it goes to 00:00 and the device shuts off.
Heating Button:
Pressing the Heating Button activates the warm mist function and is shown on the LED display with three wavy vertical lines. The water is heated in the basin by a PTC heating element and will be heated up by over 65 degrees for killing effective bacteria (Legionella). Heating the water makes the mist output finer for faster and more efficient humidification.
UV-Light Button:
Hold the UV-Light Button for 3 seconds, the device starts the UV Sterilization function, which kills the bacteria in the mist output airflow, bevor the mist enters into the room. The UV-Light icon is shown on the LED display. Press the button again and hold it for 3 seconds to stop the UV-light function.
Automatic shutdown when water tank is empty
Should the water tank be empty, a threefold acoustic signal sounds. The corresponding symbol lights up in the display while the remaining indicators go out. The device will automatically stop humidifying. In this case, turn off the device with the ON / OFF button. Let the device cool down before pouring any more water in the tank.
Caution: The device and the water in the nebulisation chamber (basin) might be very hot.
When lifting the device or removing the water tank right after operation you risk scalding yourself with the hot water!
Ensure that the water tank is always completely refilled.
The buttons on your remote control:
The Water Filter W-01W reduces the limescale in the water and the undesirable emission of limescale particles into the room surroundings. Effective for one to three months, depending on the water hardness. Hard tap water accelerates saturation of the granulate faster so that the Water Filter W-01W must be replaced earlier.
Dispose of the saturated Water Filter W-01W with your regular household waste.
The Water Filter W-01W should not be used longer than specified.
You can order the Water Filter W-01W in our online store at www.cleanairoptima.com
Replacing the Clean Air Optima® Water Filter W-01W
The Clean Air Optima CA-607W is equipped with a filter lifespan surveillance mechanism that signals that the water filter have to be replaced after 400 working hours. To show that the Water Filter W-01W need to be replaced, the humidifier emits a double zero indicator light. Reset the timer for the water filter by pressing and holding the power button for about 3 seconds. If the indicator light goes out, the timer has been successfully reset.
Placing/Replacing the Clean Air Optima® Silver Ion SI-01
The Silver Ion SI-01 uses the anti-microbial effect of silver, it prevents the growth of bacteria and smells in the water. The Silver Ion SI-01 even works when your humidifier is switched off, so the water stays fresh.
Replace the Silver Ion SI-01 at the start of the humidifier season or replace the Silver Ion SI-01 after one year of usage.
Dispose of the Silver Ion SI-01 with your regular household waste.
The Silver Ion SI-01 should not be used longer than specified.
You can order the Silver Ion SI-01 in our online store at www.cleanairoptima.com
Activating the aroma function:
Important
In order to reach the best results and to enjoy your ultrasonic air humidifier as much as possible, we advise to read carefully the following instructions regarding the use of essential oils in the ultrasonic air humidifier CA-607W.
Use of essential oils in the CA-607W
Use our high quality essential oils and enjoy your personal aromatherapy! A scent sensation at its highest level.
You can find high quality essential oils with many different scents in our assortment. They
perfectly fit to the ultrasonic air humidifier CA-607W and have been specially developed for
the use with this ultrasonic humidifier:
You can order the Essential Oils in our online store at www.cleanairoptima.com
Warning!
The use of other essential oils not made for this air humidifier or other additives (for example: fragrances and water purification products) can damage the air humidifier and must NOT be used! Never put other pure essential oils or other additives into the water tank resp. the water basin! Even a small quantity can damage the plastic and cause cracks.
The material is not made for the use of additives. One drop is enough to damage the water tank/ water basin and disable the device. Devices that are damaged through additives are excluded from the guarantee.
You can ensure many years of trouble free operation of your Clean Air Optima® CA-607W humidifier by following a few simple maintenance procedures. If your water is hard, containing high concentrations of calcium and other minerals, then over a period of time white dust will start to deposit on the various surfaces in the room. A white, film-like substance will also start to develop in the water basin, on the transducer and on the inner surface of the water tank.
This white film will impede the proper function of the transducer and the operation of the machine.
We recommend the following
How to clean the transducer
How to clean the water basin
The following is a troubling shooting guide to help you solve any issues that you may have using the Clean Air Optima® Ultrasonic Humidifier CA-607W.
Problem | Possible Cause | Solution |
No mist diffused. | Power plug not plugged in.
ON / OFF button not activated. Empty water tank. Not enough water in tank. |
Plug in device.
Press ON / OFF button. Fill tank with water. Refill tank with water. |
The mist has a strange odour. | A new device.
It either has dirty water or the water has been stagnant too long. |
Remove the water tank, unscrew the lid and let it air out in a cool area for 12 hours.
Clean the water tank and refill with clean water. |
The volume of spray mist is too low. | Too much mineral scale in the water basin and on the transducer.
Water is too dirty or water was kept too long in the tank. |
Clean transducer.
Clean the water tank and refill with clean water. |
Device is noisy. | Water tank not positioned correctly.
Not enough water in the water tank. Device is on an unstable surface. |
Correctly position water tank on the base.
Refill water in the water tank. Place device on solid and even ground. |
Spray mist is coming out of the area around the mist nozzle. | There are gaps between the housing around the nozzle and the top of the water tank. | Remove the nozzle from the top of the water tank and clean with a damp cloth. Reattach to the water tank. |
If your water is very hard (containing abnormally high levels of minerals) the humidifier may produce white dust. This is not a malfunction. The solution would be to replace the Water Filter W-01W more often or use softer water, like distilled water. Or we can recommend Clean Air Optima Air Washers, more info in our online store www.cleanairoptima.com
WARNING!
If the above recommended solutions do not work, please contact Clean Air Optima technical support at the telephone number for your region. Do not attempt to disassemble, reassemble, or repair the device as this may void the warranty.
Model CA-607W
For rooms up to 65m² / 160m³ / 699ft²
Rated voltage 220V – 240V, 50/60Hz
Rated power 25W – Max. 105W
Capacity air humidification Min. 120 ml/h – Max. 480 ml/h
Active oxygen <0.05 ppm
Sound level Silent fan < 25dB(A)
Dimensions 230 x 150 x 370 mm
Weight 3,4 kg
Water tank 5,5 L
Colour Pearl white with smoked glass water tank
Complies with EU regulations CE / WEEE / RoHS
Ask your retailer or your municipality for updated information regarding the disposal of the packaging and of the device.
Warranty Certificate for the Clean Air Optima® Ultrasonic Humidifier CA-607W.
Date of purchase: …………………………………………………………………………………………
Customers name: …………………………………………………………………………………………
Address: …………………………………………………………………………………………………….
Telephone: ………………………………………………………………………………………………….
Email: ………………………………………………………………………………………………………..
Seller’s name: ………………………………………………………………………………………………
Address: …………………………………………………………………………………………………….
The Clean Air Optima® Ultrasonic Humidifier CA-607W is subjected to strict testing procedures before leaving the factory. If within 2 years from the date of purchase the product does not perform according to the specifications, because of factory defects, the purchaser is entitled to free repairs or replacement of parts upon presentation of this warranty (provided that the malfunction or damage to the device and/or parts occurred under normal operating conditions). What is covered: All parts defective in material and workmanship. For how long: two years from purchase date. What we will do: Repair or replace any defective parts.
Other Conditions
The provisions of this warranty are in lieu of any other written warranty whether express or implied, written or oral, including any warranty of merchantability or fitness for a particular purpose. The manufacturer’s maximum liability shall not exceed the actual purchase price paid by you for the product. In no event shall the manufacturer be liable for special, incidental, consequential, or indirect damages. This warranty does not cover a defect that has resulted from improper or unreasonable use or maintenance, faulty assembly, accident, natural catastrophes, improper packing, or unauthorized tampering, alteration, or modification as determined solely by us. This warranty is void if the label bearing the serial number has been removed or defaced.
Never put other pure essential oils or other additives into the water tank resp. the water basin! Even a small quantity can damage the plastic and cause cracks.