Before installing the device, you must check the following items.
Caution: Please read the above safety guidelines carefully before device use. Users should assume responsibility for any accidents due to incompliance with the above instructions.
This chapter mainly describes the functions and the structure of the HALNy HL-4GMV.
The description of the front panel and the rear panel of the GPON ONU as follows.
Fig. 1 – Front Panel
LED | Color | Status | Description |
POWER | Green | On | The power works normally. |
Off | Powered off or the power supply is abnormal. | ||
PON | Green | Refer to Table 2: “PON LED Status Instruction” | |
LOS | Red | Refer to Table 2: “PON LED Status Instruction” | |
Internet | Green | On | Got WAN IP Address Successfully |
Blink | Data is being transmitted | ||
Off | Device in bridged mode or no IP | ||
LAN1-4 | Green | On | The connection of Ethernet interface is normal. |
Blink | Data is being transmitted through the Ethernet interface. | ||
Off | The connection of the Ethernet interface fails to establish. | ||
2.4G | Green | On | The connection of Ethernet interface is normal. |
Blink | Data is being transmitted through the Ethernet interface. | ||
Off | The connection of the Ethernet interface fails to establish. | ||
5G | Green | On | The connection of Ethernet interface is normal. |
Blink | Data is being transmitted through the Ethernet interface. | ||
Off | The connection of the Ethernet interface fails to establish. |
LED | Color | Status | Description |
Phone1-2 | Green | On | Voip account is registered |
Blink | Phone call | ||
Off | Port deactivated or Voip account is unregistered | ||
WPS | Green | On | Pairing ok |
Blink | In pairing | ||
Off | Not activated/not triggered |
Table 1. ONU LED Indication Table
PON LED Status Instruction | ||
PON | LOS | Description |
Off | Off | The ONT is disabled by the OLT |
Flash | Off | The ONT is registering to the OLT |
On | Off | The ONT has already registered to OLT |
Off | Flash | The fiber is not connected properly |
Table 2.PON LED Status Instruction
ONU Rear Panel Description:
Interface / Button | Function |
LAN1 -4 | Ethernet interface, for connecting to a computer or an Ethernet interface of a switch. |
RST | Press the button for 5 seconds to reboot ONU and restore the factory default configurations. |
Power | Connect power cable |
ON/OFF | Turn on/off the power supply. |
Phone 1-2 | RJ-11 Telephone Port |
Table 3.Rear Panel port description
ONT Bottom Panel Description:
Interface | Function |
SC/APC | GPON interface for connecting to a SC/APC patchcord |
The chapter describes the required installation operations before you use the device for the first time.
Fiber to the Home (FTTH) means installing the ONU to residences or enterprise buildings. The optical line terminal (OLT) is placed in the central equipment room. The ONU can be placed in the home of a user, or it can provide a connection for the user through the Ethernet interface, according to the user requirement. The OLT connects to the ONU with an optical distributor in a point-to-multipoint way. See the following figure.
Note:The ONU applies to installation at home or in the corridor. Because installation and cabling in the corridor are relatively complex, let the professional engineers deploy according to the actual situation. This manual describes the procedure for installing the device at home and is for reference only.
The Ethernet interface of your computer connects to the Ethernet interface of the ONU. Before installing it, ensure that an Ethernet adapter is already installed on your computer.
Step 1 Use the one end of the network cable to connect the Ethernet interface of the computer.
Step 2 Use other end of a network cable to connect the Ethernet interface on the rear panel of the HALNy HL-4GMV.
3.3.2 Connecting the Fiber
Caution:
Symptom | Solution |
The POWER indicator is not on |
|
The PON indicator is not on |
|
The LOS indicator is not on |
|
The LAN indicators are not on |
|
Main Technical Specifications | ||
Standard | GPON Standard | ITU-T G.984 |
Rate | Uplink | 1.25Gbps |
Downlink | 2.5Gbps | |
Interface | Optical interface | Single Mode |
4 LAN ports | RJ-45 10/100/1000Mbps MDI/MDIX Self Adaption | |
2 POTS ports | RJ-11 FXS | |
WiFi 2.4Ghz WiFi 5Ghz |
802.11n (2T2R MIMO) 300Mbps 802.11ac (2T2R MIMO) 876Mbps |
Physical Characteristics and Environment Requirements | |
Power adapter input | 100V~240V AC,50Hz~60Hz |
Whole-device power supply | 12V DC,1.5A |
Standard power consumption | <12W |
Operating temperature | 0˚C~45˚Sc |
Operating humidity | 10%~90% (non-condensing) |
Dimension | L x W x H:200mm x 138mm x 38mm |
Weight | <500g |
Appendix A Acronyms and Abbreviations
GPON | Gigabit Passive Optical Network |
FTTB | Fiber to the Building |
FTTH | Fiber to the Home |
OLT | Optical Line Terminal |
ONU | Optical Network Unit |
PON | Passive Optical Network |
Additional information:
Declaration of Conformity (CE)
This device has been tested and found to comply with the stated standards which are required by the Council Directive of 2014/30/EU. The device complies with this CE Declaration when the installation is done in accordance with the instruction and documentation. The importer doesn’t take responsibility for any issues caused by improper use of the device.
The full document is on the below web page and it is available in importer:
CE / warranty terms and conditions:
www.halny.com
Importer:
FIBRAIN Sp. z o.o
36-062 Zaczernie 190F (POLAND)
[email protected]
Information furnished by HALNy Networks is believed to be accurate and reliable. However, no responsibility is assumed by the importer for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of the manufacturer. The manufacturer reserves the right to change specifications at any time without notice.
Recycling
This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled according to European directive 2012/19/EU in order to be recycled or dismantled. This will minimize the negative effects on the environment and human health resulting from the possibility of the presence in the equipment substances, mixtures and hazardous components. A user can give the product to a competent recycling organization, to WEEE collection points or to a distributor (in accordance with local regulations).