luxorparts – ItsManual https://itsmanual.com Owner's manuals for all sorts of products Tue, 22 Aug 2023 07:20:09 +0000 en-US hourly 1 https://wordpress.org/?v=6.5.2 https://itsmanual.com/wp-content/uploads/2021/09/favicon.ico luxorparts – ItsManual https://itsmanual.com 32 32 luxorparts Digital timer 40710 Manual https://itsmanual.com/luxorparts/timer-40710/ Mon, 07 Aug 2023 04:23:20 +0000 https://itsmanual.com/?p=188057 Read More...

]]>

manual
Digital timer
Item:40710

Specifications

Power supply 230 V. 50 Hz
Capacity 16 A. 3600 W
Battery NiMH 1,2 V> 100 h
Program 10
Temperature -10 °C to 40 °C
Accuracy +/- 1 minute/month

Installation:

Start by plugging the timer into a free wall socket to charge the built-in battery. Let the battery charge for 10 minutes so the backup function works properly. Press the R button with a sharp object to reset the timer.

Never put two timers in the same wall socket.

Time settings

Press the PROG/+ or button until the clock is shown in the display. Press and hold the SET button for 2 seconds until MO starts flashing in the display. Change weekday with PROG/+ or -. buttons, confirm with SET. Repeat the following procedure to set the current hour and minute.

12/24 hours

Press CO and SET buttons at the same time to change the time format.

Daylight saving time

Press MANUAL and SET buttons at the same time. The clock will skip one hour ahead and display an ‘S’. Press the same buttons again to change back.

Priorities

The timer can have many active settings at the same time. Some settings are prioritized in order to not interfere.

Manual settings
Random program start
Countdown timer
Programs (Auto mode enabled)

Manual settings

Press MANUAL to switch between the On, Off, and Auto modes. Programs are only active if the Auto Mode has been chosen.

Random program start

Activate the random function by pressing RND. Your programs will act as usual except for between 18:00 to 06:00. During this time, it will alternate on/off with an interval of 10 to 31 min. Press RND again to turn off the function.

Countdown timer

Press the — button to activate the countdown feature, the CD will be shown in the display. Toggle the feature by pressing the SET button then press PflOG/+ or — to toggle if the timer should be on or off during the countdown feature. Keep pressing SET to confirm each step and set the selected time setting. When everything is set, press the CO button once again to activate the countdown. Make sure the timer is in AUTO mode, otherwise the countdown won’t work at all, the random function is also disabled during this function.

Program

Press PROG/+ once, ON should show on the display. Press SET once, MO will start flashing, change the value with PROG/+ or — and choose the day of the week or combination of days you want the program to be active. Continue by setting the time. When these steps are done press PROG/+ to proceed to set the settings for when the program should not be active. Repeat the above-mentioned steps. You’ve now set the settings for the first program, there are 9 additional programs you can set if wanted. Press PROG/+ and — at the same time to go exit the program setting mode.

Note: To revoke any program, press the MANUAL button in the program setting mode. The display will replace the program with dashes”–:–“Make sure the various programs don’t overlap, the timer will prioritize time, not program order. OFF settings are also prioritized over ON. To start the programs, make sure that the Auto mode is enabled as described under Manual Settings above. Random and/or countdown features may not be activated.

www.luxorparts.com
Box 50435 Malmo
Sweden
2020-03-23

 

]]>
luxorparts Distance meter Manual https://itsmanual.com/luxorparts/distance-meter/ Tue, 22 Aug 2023 07:20:09 +0000 https://itsmanual.com/?p=203453 Read More...

]]>
luxorparts Distance meter User Manual

www.luxorparts.com
Box 50435, Malmö, Sweden
Version: 2020-06-18

CE, Disposal & Recycle Icon

Luxorparts®

Overview

Diagramming

Switching On and Off

Measurement Function

Switch measurement unit

Selecting reference level

Backlight function

Memory function

Deleting saved values

Press the button OFF CLEAR, it will delete last measured value in all measuring functions.

Continuous Measurement (Tracking)

Adding/Subtracting Value

Adding/Subtracting values function can be used on distance, area, volume, Pythagoras measurements.

Adding Value

The following example describes the adding of areas:

  1. Press the button to start the first measurement of area value as described in section “Area Measurement”.- Image 1
  2. Press the button”+”, symbol “+” will show on the scree.- image 2
  3. Press the button to start the second area measurement as described in section “Area Measurement”, once the second measurement is completed, the result of the second area measurement will be displayed on the result line.- Image 3
  4. To show the final result, press the measurement button once more, the accumulated value will show on the result line. – image 4

Subtracting Value

To subtract values, press the button”-“. The subsequent steps are similar to “Adding Values”.

Other supplementary function settings

Measurement accuracy compensation function
  1. Long press the laser button for about 4 seconds when the product is off to enter the measurement accuracy compensation function.
  2. Press the laser button for about 2 seconds to enter the measurement accuracy compensation function setting screen. (CRL-7mm to CRL.7mm)
  3. Select the value from CRL-7 to CRL.7 according to the value you want to subtract or increase. (For example: the length you measured is 3 meters, and the measured value is 3.001 meters, then you can choose CRL-1, and the value measured again will be 3 meters. If you need to add or subtract other values, use the same Method of operation.)
Sound off/on

From the measurement accuracy compensation screen (any number from CRL-7 to CRL.7 is displayed on the screen), press the laser key for about 2 seconds to enter the sound off or on function. “BP, ON” means the sound is turned on, press the laser key again “BP.OFF” means the sound is turned off.

(According to your actual need to set to turn off or turn on the sound, press the laser key for about 2 seconds or press “OFF/CLEAR” key to save the setting.)

Backlight off/on function

From the sound on/off page, press the laser button for about 2 seconds to enter the backlight on/off function, “BL.ON” means the backlight is turned on, and press the laser key “BL.OFF” again to turn off the backlight, Turn off ort urn on the backlight. When setting to turn off the backlight, press the “OFF CLEAR” key to save and need to restart the product to take effect, but when setting to turn on the backlight, press the “OFF CLEAR” key and then press any key to take effect)

Precautions

Under the measurement accuracy compensation function, long press the laser button for about 2 seconds to enter the sound off and on function (when you press the laser button for about 2 seconds to enter the next function setting, the function you set in the previous function will be automatically saved , You can also press “OFF CLEAR” to save).The sound off and on function is also saved when entering the backlight on and off function.

However, the backlight off/on function has special operations. When setting to turn off the backlight, press the “OFF CLEAR” button to save and need to restart the product to take effect, but when setting to turn on the backlight, press any key to take effect. So please carefully confirm whether each function you set is what you need during operation to avoid mistakes.

On the backlight on/off page, long press the laser button for about 2 seconds or press “OFF CLEAR” to enter the length measurement screen (Please do not long press “OFF CLEAR” button will shut down).

Information