SUNCO – ItsManual https://itsmanual.com Owner's manuals for all sorts of products Mon, 04 Sep 2023 13:08:17 +0000 en-US hourly 1 https://wordpress.org/?v=6.5.2 https://itsmanual.com/wp-content/uploads/2021/09/favicon.ico SUNCO – ItsManual https://itsmanual.com 32 32 SUNCO LED Ceiling Panel manual https://itsmanual.com/sunco/led-ceiling-panel/ Sun, 23 Apr 2023 13:38:59 +0000 https://itsmanual.com/?p=77246 Read More...

]]>
 

SUNCO LED CEILING PANEL 40W Install Guide and Manual

EASY INSTALLATION RECESSED

Required Tools: Drill, Ladder, Hammer, Pliers, Tape Measure, Pencil, Philips Screwdriver.

Prior to install, remove the existing light fixture (if any) from the ceiling.

  1. Turn off the switch and circuit breaker before installing this LED light fixture.
  2. Turn the Ceiling Panel face down on a flat surface.
    • Unscrew the (2) driver covers and set aside the screws.
  3. Pop out (2) knockouts (choice of 6).
  4. Connect conduit to each knockout.
    • Pass wires through.
  5. Connect the supply wires to the Ceiling Panel wires with included wire nuts.
    • Black to Black (live);
    • White to White (neutral);
    • Green to Green (ground).
  6. (Optional) If using a dimmer (not included), connect DIM+ and DIM- wiring of Ceiling Panel to your dimmer with included wire nuts.
  7. Replace driver covers.
    • Tighten the screws.
  8. Locate the (2) protective brackets on back of panel. Bend up 90°.
  9. Twist 90° so hook faces outside edge of Ceiling Panel.
  10. Install LED Ceiling Panel light in ceiling, using protective brackets.
  11. Turn on circuit breaker and test the light.

WARNING

To reduce the risk of fire, electric shock or injury to people:

  • Installation should be performed by a professional, qualified electrician familiar with the construction and operation of this product and the hazards involved.
  • Abide by related regional and local laws or regulations.
  • Proper grounding is required to ensure safety.
  • Not suitable for a wet environment.
  • LED must be installed in an appropriate environment to work. Harsh environments may shorten the life or damage the light.
  • Check for damage during shipping prior to install. If the product is damaged, do not use it.
  • Turn off the switch and circuit breaker before installing this LED light fixture. Accurately verifying no voltage on the lines with an appropriate meter is recommended prior to install.
  • After verifying no voltage, disconnect wires and remove existing light fixture from ceiling (if any).
  • To ensure efficient light, regularly clean the light panel. Don’t clean with harsh solvents; use a dry cloth.
  • Use safety precautions. Safety eyeglasses and gloves are recommended.

WIRING DIAGRAM

To make the light panel dimmable, connect a compatible dimmer (not included) to the dimming signal wires of the luminaire. Suitable for Constant Current Reduction Dimming 0-10V.

EASY INSTALLATION SUSPENSION

Required Tools: Drill, Ladder, Hammer, Pliers, Tape Measure, Pencil, Philips Screwdriver.

NOTE: 2 piece suspension kits (not included) required for suspension install.

  1. Turn off the switch and circuit breaker before installing this LED light fixture.
  2. Turn the Ceiling Panel face down on a flat surface.
    • Unscrew the (2) driver covers and set aside the screws.
  3. Pop out (2) knockouts (choice of 6).
  4. Connect conduit to each knockout.
    • Pass wires through.
  5. Connect the supply wires to the Ceiling Panel wires with included wire nuts.
    • Black to Black (live);
    • White to White (neutral);
    • Green to Green (ground).
  6. (Optional) If using a dimmer (not included), connect DIM+ and DIM- wiring of Ceiling Panel to your dimmer with included wire nuts.
  7. Replace driver covers.
    • Tighten the screws.
  8. Drill (2) holes in the ceiling. Place the anchors into hole. Insert the wire rope and screw.
    • Refer to install manual of your suspension kit for complete details.
  9. Adjust the support rope/wire so Ceiling Panel hangs horizontally.
    • Suspension kit is not included.
  10. Install LED Ceiling Panel light in ceiling, using protective brackets.
  11. Turn on circuit breaker and test the light.

WARNING

To reduce the risk of fire, electric shock or injury to people:

  • Installation should be performed by a professional, qualified electrician familiar with the construction and operation of this product and the hazards involved.
  • Abide by related regional and local laws or regulations.
  • Proper grounding is required to ensure safety.
  • Not suitable for a wet environment.
  • LED must be installed in an appropriate environment to work. Harsh environments may shorten the life or damage the light.
  • Check for damage during shipping prior to install. If the product is damaged, do not use it.
  • Turn off the switch and circuit breaker before installing this LED light fixture. Accurately verifying no voltage on the lines with an appropriate meter is recommended prior to install.
  • After verifying no voltage, disconnect wires and remove existing light fixture from ceiling (if any).
  • To ensure efficient light, regularly clean the light panel. Don’t clean with harsh solvents; use a dry cloth.
  • Use safety precautions. Safety eyeglasses and gloves are recommended.

SPECIFICATIONS

Voltage 100-277V
Wattage 40W
Suitable for Locations Ingress Damp
Housing SPCC+PS lens
Weight 4.85 lbs
Warranty 10 years


]]>
SUNCO 6” Slim Selectable White Led Light Manual https://itsmanual.com/sunco/selectable-led-light/ Mon, 04 Sep 2023 13:08:17 +0000 https://itsmanual.com/?p=214023 Read More...

]]>

6” Slim Selectable White Led Light

COMPONENTS

IC Rated Junction Box

EASY INSTALLATION

  1. Turn off circuit breaker that provides power to the light switch for the recessed lights.
  2. Cut a hole in the ceiling in the desired location accordingly to the dimension indicated.
  3. Run electrical wire from the power source (switch) through the mounting hole.
  4. Open the junction box and remove the appropriate knockout(s) on the side plate.
  5. Connect the supply wires to the junction box wires using the wire nuts provided.
    • White to white
    • Black to black
  6. Tuck the connected wires inside the junction box and close the cover.
  7. Connect the junction box to the slim down light. Tighten the connector by hand.
  8. Turn on power and test light.
  9. BEFORE PROCEEDING:
    On back of j-box, slide the CCT Selection Switch to choose from five color temperatures (2700K, 3000K, 3500K, 4000K, 5000K). Try each CCT to determine which suits your room.
    • Light will use the preferred setting whenever you turn on switch.
    • Turn off light switch and continue install.
  10. Insert junction box through the hole in the ceiling.
    • New construction applications: Hardwire box shall be secured to studs, joists, or similar fixed structural units.
    • Remodel applications: Do not require the hardwire box to be firmly secured after the mounting plates studs, joists, or structural units have been concealed.
  11. Push up the spring clips to insert the luminaire in the opening in the ceiling.
  12. Turn on circuit breaker and test the light.

WARNING

To reduce the risk of fire, electric shock or injury to people:

  • This product should be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
  • Abide by related regional and local laws or regulations.
  • Do not alter, relocate or remove wiring.
  • Do not make or alter any open holes in enclosure or electrical components.
  • Proper grounding is required to ensure safety.
  • Check for damage during shipping prior to install. If the product is damaged, do not use it.
  • Turn off the switch and circuit breaker before installing this LED light.
  • Use safety precautions. Safety eyeglasses and gloves are recommended.
  • Please review instructions carefully before proceeding.

SPECIFICATIONS

Voltage: 120V
Wattage:  14W
Suitable for Locations Ingress: Damp
Housing:  Polycarbonate
Weight:  0.59 lbs
Warranty:  7 years

]]>