Quick Start Guide

Package Contents

Camera Unit Remote Control Power Adapter & Power  Plug* USB 2.0 Type-B to Type-A Cable  (5m)
AVER Conference Camera - Camera Unit AVER Conference Camera - Remote AVER Conference Camera - Type-A Cable
Mini DIN9 to Mini DIN8 RS232 Adapter Cable L-Mount Brackets Screws for Mount Drilling Paper QR Code Card
AVER Conference Camera - Brackets AVER Conference Camera - Drilling Paper

* The power plug will vary depending on the standard power outlet of the country where it is sold.

Overview

  1. Status LED
  2. IR Sensor
  3. USB 3.1 Type B Port
  4. RS232 In/Out Port
  5. DC 12V Power Plug
  6. PoE Port*
  7. Kensington Lock

* Power over Ethernet (PoE), compatible with IEEE 802.3AT/802.3AF. Please use CAT 5e FTP cable (not included.)

Installation

1. Connect the camera to power outlet.

2. Connect the necessary cables.
[Notes]
– Secure the USB and RS232 cables with attached screws.
– Make sure the cable is well connected to the connector on the camera before securing the cable.

AVER Conference Camera - Connect

3. Connect the camera to the computer/laptop.
[Notes]
– Use the USB 2.0 cable included in the package.
– CAM520 Pro2 has the USB 3.1 port which is USB 2.0 compatible.
Maximum resolution/fps for USB 2.0 and USB 3.1 port are shown below.

AVER Conference Camera - Connect the camera

M-JPEG/fps NV12/fps YUV/fps
USB 2.0 1080@/60 fps 720p@/10 fps

480p@/30 fps

720p@/10 fps

480p@/30 fps

USB 3.1 1080p@/60 fps 1080p@/30 fps 1080p@/30 fps

4. Connect Ethernet cable for IP streaming and remote camera control.
[Notes]
– To ensure the stability of IP video streaming, please use CAT 5e FTP cable.

Remote Control

AVER Conference Camera - Remote Control

* Not supported for CAM520 Pro2

  • AAA Batteries (required)
  • Preset (): The Preset button on the remote serves 2 functions.
    To Save a Preset – Move camera to desired position. Press and hold the preset button until you receive the save message on the screen. Select preset position button 0-9 to store the current camera position. Repeat steps if needed.
    To Load a Preset – Press the preset button and preset position button 0-9 to load a saved camera position. Repeat steps if needed.
  • Press and hold the number button “1” for 1 second to turn on or off the WDR function.
  • Press and hold the number button “5” for 1 second to turn on or off the SmartFrame function.
  • Press and hold the number button “8” for 1 second to enable or disable RTMP streaming function.
  • Press and hold the number button “9” for 1 second to force camera to enter sleep mode. This will end any video streaming. To wake up the camera, press the button or any directional button for 1 second. This mode is not functional while USB streaming is on.
  • Camera Select (AVER Conference Camera - Camera Select): If you only have one camera and do not need to adjust any setting, the default is camera 1. If you press camera 2 or 3 on the remote control, you will find your remote can’t control your camera. In this case, please press camera 1 on your remote again.
  • SmartFrame (): Press for 1 second to switch the SmartFrame function among Manual Framing/Auto Framing/ Preset Framing modes. A message (as figures shown) will display on the screen to indicate the mode.

Manual Framing               Auto Framing               Preset Framing
Note] SmartFrame deploys face and body detection technology. People wearing masks and side facial profiles can still be detected. The maximum detection distance is 7-10 meters. Set up preset points in advance (Only for Preset point 1-9. Preset 0 is for home position).

Wall Mount Installation

  1. Use the drilling paper included in the package to drill the holes in the wall where the user wants to mount the camera.
  2. Use the screws (not included) to secure the L-mount bracket A on the wall.
    [Note] For cement wall: M4 x20mm self-tapping screws (x4) + Plastic conical anchor For wooden wall: M4 x20mm self-tapping screws (x4)
  3. Then, assemble the L-mount brackets A + B with 2 screws (M4 x8mm, included in the package).
  4. After assembling the L-mount brackets, use the screws (not included) to secure the lower part of L-mount brackets on the wall.
    [Note] For cement wall: M4 x20mm self-tapping screws (x2) + Plastic conical anchor For wooden wall: M4 x20mm self-tapping screws (x2)
  5. Pass the cables through the hole on the L-mount brackets and connect the cables to corresponding connection ports.
  6. Use the remaining screws (1/4”-20 L=7.5mm, included in the package) to secure the camera on the L-mount brackets.

AVER Conference Camera - Wall Mount Installation

Making a Video Call

A computer is required to use this device.
1. Open your video collaboration application such as Zoom, Microsoft® Teams, Skype for Business, Skype, Google Meet, Intel® Unite™, RingCentral,  BlueJeans, V-Cube, LiveOn, CyberLink U Meeting® TrueConf, Adobe Connect, Cisco WebEx®, Fuze, GoToMeeting™, Microsoft® Lync™, Vidyo, vMix, WebRTC, Wirecast, XSplit.,
2. Set the CAM520 Pro2 as your primary camera device in your application (Please consult your application setup guide for details).
3. Ready to make a video call.
[Note] CAM520 Pro2 is a Plug-n-Play Conference Camera. The system requires no special drivers. For advanced setting and firmware update, please download PTZApp 2.

Making a Connection through the Browser

CAM520 Pro2 has an Ethernet port for IP streaming and allows administrators to remotely control and set up the camera via internet access. Moreover, CAM520  Pro2 also supports RTSP and RTMP functions. For more details, please refer to the user’s manual or contact our technical support.
1. Make sure the  CAM520 Pro2 has an internet access connection.
2. Launch PTZApp 2* () and connect CAM520 Pro2 to PC with USB cable.

3. The camera’s default IP address is 192.168.1.168. Click the pencil icon (AVER Conference Camera - Symbole 2) to edit IP address**.

4. Click weblink icon () to launch Chrome page. Please enter the password (default password is aver4321).
[Note] The browser supports:

  •  Chrome: version 76.x or above
  • Firefox: version 69 or above
  • IE: Doesn’t support

5. After editing IP address, user can access web settings of the camera with only Ethernet cable connection. Unplug the USB cable.
6. The main web screen is displayed as below.

AVER Conference Camera - displayed

* In PTZApp2, user can change the IP address setting of CAM520 Pro2, configure the parameters of the camera, set up AI tracking functions and some advanced image settings, pan, tilt, and zoom the camera. Please refer to the user manual for details. Please go to https://www.aver.com/download-center (Global  & European Headquarters) or https://www.averusa.com/business/support/ (USA) to download the PTZApp 2. After downloading, double-click on the file and follow the on-screen instructions to complete the installation. After installing the PTZApp 2, double-click on the PTZApp 2 icon to run the application.

** To support IP address changes in groups, user can download AVer IP Finder app.
1. Download the IP Finder from https://www.aver.com/download-center (Global & European Headquarters) or https://www.averusa.com/business/support/  (USA).
2. Run the IP Finder.
3. Click “Search”, and all available devices will be listed on the screen.

FEDERAL COMMUNICATIONS COMMISSION

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operating in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Warning:
This is a class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. This Class A digital apparatus complies with Canadian ICES-003.
Caution:
Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions.
COPYRIGHT
©2021 AVer Information Inc. All rights reserved.
MORE HELP
For FAQs, technical support, software and user manual download, please visit:
Global: https://www.aver.com/download-center/
USA: https://www.averusa.com/business/support/
European Headquarters: https://www.aver.com/download-center/

Technical Support:
Global: https://aver.com/technical-support
USA: https://averusa.force.com/support/s/contactsupport
European Headquarters: https://www.avereurope.com/technical-support/

CONTACT INFORMATION

Global
AVer Information Inc.
https://www.aver.com
8F, No.157, Da-An Rd.,
Tucheng Dist.,
New Taipei City 23673,
Taiwan
Tel: +886 (2) 2269 8535

USA
AVer Information Inc.
https://www.averusa.com
668 Mission Ct.,
Fremont, CA 94539
Tel: +1 (408) 263 3828
Toll-free: +1 (877) 528 7824
Technical support: [email protected]

European Headquarters
AVer Information Europe B.V.
https://www.avereurope.com
Westblaak 140, 3012KM,
Rotterdam, Netherlands
Tel: +31 (0) 10 7600 550
Technical support: [email protected]