Loading manuals...

Bestway 58383 Flowclear Filter Pump Manual


Bestway 58383 Flowclear Filter Pump Manual Image

Bestway 58383 Flowclear Filter Pump User Manual

WE SUGGEST NOT RETURNING THE PRODUCT TO THE STORE QUESTIONS? PROBLEMS? MISSING PARTS?
For FAQs, Manuals, Videos, Or For spare Parts, Please Visit bestwaycorp.com/support

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS
Carefully read, understand, and follow all information in this user manual before installing and using the Filter Pump. These warnings, instructions, and safety guidelines address some common risks of water filtration systems, but they cannot cover all risks and dangers in all cases. Always use caution, common sense, and good judgment when enjoying any water activity. Retain this information for future use. In addition, the following information can be supplied depending on the Filter Pump type. Keep the instructions in a safe place. If the instruction is missing, search for it on the website www.bestwaycorp.com/support.

WARNING

  • The pump is to be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • The plug of the pump shall be at least 3.50 m away from the pool.
  • The pump cannot be used while people are inside the pool.
  • The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • When the appliance will be not used for a long time, such as in the winter, the pool set should be disassembled and stored indoors.
  • The appliance must be placed more than 2 m away from the pool. Electric installations should follow national wiring rules.
  • Only the media provided or specified by the manufacturer is to be used with product installation.
  • It is essential to check that the suction openings are not obstructed.
  • It is advisable to stop the filtration during maintenance operations on the filtration system.
  • Regularly monitor the filter clogging level.
  • A weekly check is recommended for cleaning.
  • A minimum daily filtration operating time of 8 hours is recommended to ensure clear pool water.
  • It is essential to change any damaged element or set of elements as soon as possible. Use only parts approved by the person responsible for placing the product on the market.
  • All filters and filter media shall be inspected regularly to ensure that there is not a build-up of detritus thus preventing good filtration. The disposal of any used filter media should also be in accordance with applicable regulations/legislation.
  • The water circulation installation shall comply with European as well as national/local regulations, especially when dealing with electrical issues. Any change in valve position, pump size, or grille size can cause a change in the flow and the suction velocity can be increased.
  • It is necessary to have the plug accessible after the installation of the pool.
  • Please read the instruction manual carefully and keep it for future reference.
  • If the instruction is missed, please contact Bestway or search for it on the website: www.bestwaycorp.com.

DISPOSAL

Electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

SAFETY TECHNICAL INSTRUCTIONS

  • The appliance must be supplied by a grounded power source.
  • Extension cords can’t be used.
  • In case of damage to the filter pump, do not use the pool.
  • Do not bury the cord. Locate cord to minimize abuse from lawnmowers, hedge trimmers, and other equipment.
  • This pump is for use with storable pools only. Do not use permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.
  • Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of the pump.
  • When working with electricity, turn the electrical power off at the circuit breaker and lock the breaker door. Failure to do so will result in an increased risk of shock, injury, and possibly death.
  • Do not remove the grounding prong or modify the plug in any way. Do not use adapter plugs. Consult a qualified electrician for any questions related to the validity of your plug’s grounding.
  • Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump.
  • Cleaning and user maintenance must be performed by an adult above 18 years old who is familiar with the risk of electric shock.
  • Consult a qualified electrician for any questions.
  • In case of doubt on the pump or any circulation devices, contact a qualified installer, or the manufacturer/importer/distributor.
  • Mind all the safety requirements and recommendations described in the manual.
  • Please examine the equipment before use. Notify Bestway at the customer service address listed on this manual for any manufacturing defect or missing parts at the time of purchase. Verify that the equipment components represent the filter pump model that you had intended to purchase.
  • Atmospheric conditions may affect the performance and life span of your filter pump. Unnecessary wear and tear may occur during periods of cold, heat, and exposure to the sun. Whenever possible, shelter the pump from these conditions.
  • It is important to ensure the factory-equipped stopper plugs for the inlet and outlet ports replace the screens before removal or maintenance on the pump is attempted.
  • Do not add chemicals to the filter pump.
  • Don’t plug or unplug the appliance if your hand is wet.
  • Always unplug the appliance: on rainy days, before cleaning or other maintenance, and when leaving it unattended on holidays.
  • This product is not intended for commercial use.

ATTACHING A BASE

FOR 330GAL
EN60335-2-41 TEST standard requires the filter pump to be vertically fixed on the ground or a base made of wood or concrete before use. There should be two holes 9 mm in diameter on the base, the space between which should be 127 mm. Put the filter pump on the base and attach them together by fastening the bolts and nuts. All the base parts should weigh at least over 18 kg to prevent the pump from accidentally falling.

FOR 530GAL
EN60335-2-41 TEST standard requires the filter pump to be vertically fixed on the ground or a base made of wood or concrete before use. There should be two holes 9 mm in diameter on the base, the space between which should be 159 mm. Put the filter pump on the base and attach them together by fastening the bolts and nuts. All the base parts should weigh at least over 18 kg to prevent the pump from accidentally falling.

FOR 800GAL
EN60335-2-41 TEST standard requires the filter pump to be vertically fixed on the ground or a base made of wood or concrete before use. There should be two holes 9 mm in diameter on the base, the space between which should be 166 mm. Put the filter pump on the base and attach them together by fastening the bolts and nuts. All the base parts should weigh at least over 18 kg to prevent the pump from accidentally falling.

SETUP

What’s In The Box

Setting

Flame

CHECKLIST
To check the parts included in the box, consult the part list inside this manual. Verify that the equipment components represent the model that you had intended to purchase. In case of any damaged or missing parts at the time of purchase, visit our website bestwaycorp.com/support.

CHOOSE THE CORRECT LOCATION
Place the Filter Pump on a solid and level ground; it must be positioned on the same level as the base of the pool. If the Filter Pump is in an upper or lower position than the base of the pool, the performance and life span of the Filter Pump can be compromised. The pool and the Filter Pump have to be positioned in an area with adequate drainage and easy access for maintenance operations. Never place the Filter Pump in an area that may accumulate water.

INSTALLATION

  • For the installation instructions, refer to the illustration steps. Drawings are for illustration purposes only. May not reflect the actual product. Not to scale.
  • Bestway will not be responsible for any damage caused to the Filter Pump due to mishandling or failure to follow these instructions.
  • It is imperative to check that the hydraulic connectors are not obstructed.
  • Do not dry run the Filter Pump. Make sure both the pool’s inlet and outlet valves are fully covered by water before operating the Filter Pump.

MAINTENANCE

  • Make sure that the Filter Pump is unplugged before any maintenance.
  • For the maintenance instructions, refer to the illustration steps inside this manual. Drawings are for illustration purposes only. May not reflect the actual product. Not to scale.
  • To optimize the Filter Pump performance and for sanitary reasons, we suggest replacing the filter cartridge with a new one every two weeks.

STORAGE

  • Remove all accessories; be sure that Filter Pump, hoses, and debris screens are completely clean and dry before storage. If all the parts are not completely dry, mold may result.
  • Before storage, remove and dispose of the filter cartridge.
  • We strongly recommend disassembling the Filter Pump when the environment temperature is below 10ºC / 50ºF.
  • Store the Filter Pump in a dry place with a moderate temperature between 10ºC / 50ºF and 38ºC / 100ºF.

WARRANTY TERMS

For information concerning warranty terms, visit our website at: www.bestwaycorp.com.©2022 Bestway Inflatables & Material Corp. All rights reserved Trademarks used in some countries under license from/ Bestway Inflatables & Material Corp., Shanghai, China Manufactured, distributed, and represented in the European Union by/ Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, Unit 2/98-104 Carnarvon St Silverwater, NSW 2128, Australia
Tel: Australia: (+61) 2 9037 1388; New Zealand: 0800 142 101 Distributed in the United Kingdom by Bestway Corp UK Ltd. 8 Wentworth Road, Heathfield Industrial Estate, Newton Abbot, Devon, TQ12 6TL Exported  Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong www.bestwaycorp.com


More Manuals From Bestway