WARNING

IMPORTANT SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS

  • WARNING-RISK OF ELECTRIC SHOCK- The pump cannot be used while people are inside the pool.
  • WARNING-TO REDUCE THE RISK OF INJURY, do not permit children to use this product unless they are closely supervised at all times.
  • WARNING-RISK OF ELECTRIC SHOCK- Connect only to a grounding-type receptacle protected by a ground-fault circuit interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI.
    CAUTION – To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.
  • DO NOT BURY THE CORD. Locate cord to minimize abuse from lawnmowers, hedge trimmers, and other equipment.
  • WARNING – To reduce the risk of electric shock, the supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
  • WARNING- To reduce the risk of electric shock, do not use an extension cord to connect the unit to the electric supply; provide a properly located outlet.
    CAUTION:
  • This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.
    CAUTION- For continued protection against possible electric shock this unit is to be mounted to the base in accordance with the installation instructions.
    IMPORTANT- Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of the pump.
  • RISK OF ELECTRIC SHOCK- When working with electricity, turn the electrical power off at the circuit breaker and lock the breaker door. Failure to do so will result in an increased risk of shock, injury, and possibly death.
  • DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related to the validity of your plugs grounding.
    Handle the pump with care. Do not pull or carry the pump by the power cord.
    Never pull a plug from the outlet by yanking the power cord. Keep cord free from abrasions.
    Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump.
    NOTE: Please examine equipment before use. Notify Bestway at the customer service address listed on this manual for any manufacturing defect or missing parts at the time of purchase. Verify that the equipment components represent the filter pump model that you had intended to purchase.
    NOTE: Place the pump on solid and level ground. Pay attention to the position of the pool and pump so adequate ventilation, drainage, and access for cleaning are available. Never place a pump in an area that may accumulate water, or in an area where foot traffic will flow around the pool.
    NOTE: Atmospheric conditions may affect the performance and life span of your filter pump. Unnecessary wear and tear may occur during periods of cold, heat, and exposure to the sun. Whenever possible shelter pump from these conditions.
    NOTE: Do not add chemicals to the filter pump.
    NOTE: Assembly and disassembly by adults only.
    The pump is to be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA. WARNING-This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
    Electric installations should follow national wiring rules, consult a qualified electrician with any questions.
  • THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
  • FOR USE WITH SWIMMING POOLS ONLY.
  • CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARDS, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
  • WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING-TYPE RECEPTACLE PROTECTED BY A GROUND-FAULT CIRCUIT INTERRUPTER (GFCI).
  • CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY – DO NOT USE WITH PERMANENTLY-INSTALLED POOLS.
  • CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
  • CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN  ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
    SAVE THESE INSTRUCTIONS.

PEDESTAL FIXING Fig.1
EN60335-2-41 TEST standard requires the filter pump must be vertically fixed on the ground or a certain pedestal made of wood or concrete before use. There should be two holes 9mm in diameter on the pedestal, the space between which should be 163mm. Put the filter pump on the pedestal and fix them together by fastening the bolts and nuts. All the pedestal parts should weigh over 18kgs at least to prevent the pump from accidentally falling.

OPERATION
1) Open/unscrew the Air Purge Valve on the top of the Filter Pump; the air is released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valve screw it closed and wipe away any water.
3) To start the Filter Pump, insert the plug.

NOTE: To prevent the risk of electrical shock, ensure your hands are completely dry when plugging in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP –
Make sure both the pool’s Inlet and Outlet valves are fully covered by water before operating the filter pump
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.

1) Unplug the Filter Pump.
2) Stop water flowing to the Filter Pump refer to the pool’s manual.
3) Unscrew the Filter Cap Retainer and remove the Filter Cap.
4) Clean the Filter Cartridge with a garden hose. If the filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
5) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
6) Check that the Filter Cap Seal is in place.
7) Replace the Filter Cap and screw the Filter Cap Retainer into position.
8) Open Valve A and B.
9) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.

IMPORTANT: To ensure pool water stays clean, please clean the filter cartridge every day. For sanitary reasons we suggest replacing the Filter Cartridge with a new one every
two weeks.

PUMP STORAGE

1) Unplug the Filter Pump.
2) Stop water flowing into the Filter Pump and remove the Filter Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of the reach of children.
Storage temperature: 4-40°C (39.2-104°F)
7) Drain the pool according to the Pool Owner’s Manual.

PUMP WARRANTY

For information concerning pump warranty please visit our website at: www.bestwaycorp.com

For support please visit us at:
bestwaycorp.com/support

©2021 Bestway Inflatables & Material Corp.

All rights reserved
Trademarks used in some countries under license from
Bestway Inflatables & Material Corp., Shanghai, China
Manufactured, distributed, and represented in the European Union by
Bestway (Europe) S.r.l., Via Resistenza, 5, 20098 San Giuliano Milanese (Milano), Italy
Distributed in North America by
Bestway (USA) Inc., 3411 E. Harbour Drive, Phoenix, Arizona 85034, United States of America
Tel: +86 21 69135588 (For U.S. and Canada)
Distributed in Latin America by
Bestway Central & South America Ltda, Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile
Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, Unit 2/98-104 Carnarvon St Silverwater, NSW 2128, Australia
Tel: Australia: (+61) 29 0371 388; New Zealand: 0800 142 101
Distributed in the United Kingdom by Bestway Corp UK Ltd. 8 Wentworth Road, Heathfield Industrial Estate, Newton Abbot, Devon, TQ12 6TL
Exported by
Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited
Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong
www.bestwaycorp.com



More Manuals From Bestway