Loading manuals...

enocean starter set N° 61 doorbell ES61-CH NASS Manual


enocean starter set N° 61 doorbell ES61-CH NASS Manual Image

ES61-CH NASS

Manual
starter set N° 61 door bell
EnOcean-Technologie (868 MHz)

Typ / Type Art.-No./Item N° Designation
ES61-CH
NASS
9100 061 Preconfigured set consisting of wall-mounted transmitter WSNASS and switching actuator  miniS01, 1 closing  contact 16  A    230 V~,  supply voltage 230 V~

BRIEF INSTRUCTION

  • Attach switching actuator according to plan
  •  Mount wall-mounted transmitter
  •  Done!

FUNCTIONS

  • S04 On-impulse
  • X01 Gateway
  •  Repeater

FEATURES

  • Plug&Play – completely preconfigured set
  •  The included wall-mounted transmitter is already programmed with function S04 On-impulse
  • Pulse duration = 3 seconds
  • Up to 50 transmitters can be programmed
  • All functions can be programmed via E-Tool software
  • Extremely compact design
  • Extension input
  • Thermal and overload protection
  •  IP55 (wall-mounted transmitter)
  • Bidirectional EnOcean radio technology 868.3 MHz
  • EnOcean Equipment Profile (EEP) D2-01-00

GENERAL

The Omnio actuators (receivers) are controlled by radio signals from the Omnio transmitters. Each transmitter can control an unlimited number of actuators within its transmission range. The radio transmitters are manually taught in and taught out to the actuator by a simple procedure. With the Omnio software E-Tool, all  Omnio actuators can be configured via radio even without manual access to the device.

PRODUCT DESCRIPTION

The Omnio starter set N° 61: doorbell is a preconfigured set for switching electrical loads. It can be installed without further configuration. The set consists of an Omnio switching actuator miniS01 and n Omnio wall-mounted transmitter S-CH102, which is already programmed with the function S04 On-impulse. Its non-isolated 230 V~ output is able to be controlled by up to 50 Omnio radio transmitters.

Each transmitter can be programmed with the function S04 On-impulse. Via E-Tool software, the repeater can be activated as well. The extension input is preconfigured by default with the function S04  On-impulse. Bidirectional communication,  EEP 01-00. Suitable as a built-in unit. The wall-mounted transmitter is suitable for mounting in the wet and outdoor areas  (IP55).

DISPLAY AND OPERATING ELEMENTS

Terminals

  •  L line voltage L 230 V~
  • N line voltage N 230V~
  • T extension input
  • L’ relay output 230V~

Operating elements

  •  LRN learn button
  • LED LED red/green

INSTALLATION

This device is suitable for flush-mounted sockets installed indoors (dry rooms) through authorized personnel in compliance with the technical data and common safety regulations.
This device needs to be protected by a 1 A circuit breaker.

CONFIGURATION WITH E-TOOL

Omnio actuators can be configured either manually on the device itself or by radio with the software E-Tool  Gold license. Please contact AWAG Elektrotechnik AG at www.awag.ch to obtain the license. The software and a detailed description of the Omnio system and all its functions can be found on the website www.omnio.ch. By default, remote commissioning is unlocked for half an hour at the power-on of the device. It can also be unlocked via a security code. The default value of the security code is A9081919.

MANUAL CONFIGURATION

The transmitter included in the set is already programmed. A maximum of 48 further transmitters can be programmed.

PROGRAM TRANS MITTE R

The programming model is indicated by a green blinking LED. At programming, the transmitter is assigned the function S04 On-impulse on the actuator. The transmitter must not be further than 5 m away from the actuator. Further functions can be programmed by E-Tool software, see also Table  1 FUNCTIONS.

  1. Enable programming mode by pressing the LRN  button The  LED blinks green.
  2. Press transmitter twice. The LED flickers green five times and then blinks.
  3.  Quit programming mode by pressing the LRN  button. The LED goes out.

DELETE TRANS MITTER

The deletion mode is indicated by a red blinking LED. Both sides of the rocker need to be deleted separately,  see also Table 2 DELETE TRANSMITTER.

  1.  Enable deletion mode by pressing the LRN button > 7 s. The LED blinks red.
  2.  Press the upper side of the rocker twice. The LED flickers green five times and then blinks.
  3.  Press the lower side of the rocker twice. The LED flickers green five times and then blinks.
  4. Quit deletion mode by pressing the LRN button. The LED goes out.

DELETE ALL TRANS MITTE RS

  • Enable deletion mode by pressing the LRN button > 7 s. The LED blinks red.
  •  Press the LRN button 2 s. The LED flickers green five times and then goes out.

FACTORY RESET

Reset device parameters to default values, see also Table 2 DELETE TRANSMITTER.
Attention: Programmed transmitters remain.

  1. Enable deletion de by pressing the LRN button >  7s. The LED blinks red.
  2.  Enable reset mode by pressing the LRN button > 7 s. The LED blinks quickly in the red.
  3. Press the LRN button 2 s. The  LED flickers green five times and then goes out.
Table 1 FUNCTIONS

SWITCH FUNCTIONS

2 s drücken press 2 s Taste 2x drücken press button 2x drücken press S04: On-impulse Doorbell function, default = 3 s. Off when button released
2 s drücken press 2 s UTE D2-01-00 drücken press X01 Gateway Program gateway

Example:
S04 On-impulse: LRN (2 s) – press button 2x – LRN

Table 2

DELETE TRANSMITTERS

7 s drücken
press 7 s
Taste I 2x drücken Taste O 2x drücken press button I 2x press button O 2x drücken press Rocker Both buttons need to be deleted separately
LRN-Taste 7 s drücken press LRN-button 7 s 2 s drücken press 2 s Delete all transmitter
Factory reset Programmed transmitters remain

Example:  Press LRN 7 s – press button I 2x – press button O 2x – press LRN
Delete both sides of a rocker:

Table 3
DEVICE PARAMETERS
Default values are underlined
START-UP BEHAVIOUR
nur mit E-Tool konfigurierbar only configurable via E-Tool Off
On
Relay keeps state
Pulse 1 s
DEVICE COMMAND
nur mit E-Tool konfigurierbar only configurable via E-Tool Reset energy counter
2 s drücken press 2 s drücken press Start UTE teach-in sequence
7 s drücken press 7 s Start UTE teach-out sequence
REPEATER

In case of problems with the reception quality, the repeater function can be activated. The actuator will amplify the received radiograms and retransmit them. Only one device must be activated asa repeater within a radius of 5 meters.

nur mit E-Tool konfigurierbar only configurable via E-Tool Off
Level 1, repeats original radio telegrams
Level 2, as level 1 and also retransmitted radio telegrams
nur mit E-Tool konfigurierbar only configurable via E-Tool RPS rocker On: AI  Off: AO RPS push-button
On: AI pushed
Off: AI released
4BS EEP A5-11-01
VLD EEP D2-01-00
FEEDBACK TELEGRAM TYPE
nur mit E-Tool konfigurierbar only configurable via E-Tool No feedback
On change of state and every 3 min On change of state and every 30 s
SECURITY CODE ALLOWED

By default, the security code A9081919 can be used to enable remote access via E-Tool, so that the service technician has access to the actuator in the event of a fault. If this is not desired,this function must be switched off.

nur mit E-Tool konfigurierbar only configurable via E-Tool Yes
No
MINIS01 TECHNICAL SPECIFICATIONS
230 V- / 50 Hz Voltage supply
< 0.5 W Standby power consumption
16 A External device protection
1 Schliesskontakt NO 230 V- 1 closing contact NO 230 V- Relay output
16 A Maximum continuous current
2.5 mm2 Screw terminals
IP20 Protection class
Lastabschaltung bei (Last > 16 A
LED blinkt rot, 30 s Erholungszeit
load switch off at IL., > 16 A
LED flashes red, 30 s recovery time
Overload protection
Lastabschaltung bei TMCU > 75 °C
LED blinkt rot, 5 Minuten Erholungszeit
load switch off at Tmcu > 75 °C
LED flashes red, 5 minutes recovery time
Thermal protection
Ja
yes
Extension input
50 Number of sensor memory locations
EnOcean 868 MHz Technology
EnOcean TCM 515 bidirektional / bidirectional Radio module
D2-01-00 EnOcean Equipment Profile (EEP)
-10…+40 °C / 5 … 85 % rH non condensing Environment
PC ABS magenta
39.9 x 39.9 x 18.3 mm
Housing
30 g Weight
EN 60669-2-1 Standards

LRN button

Transmitter button (rocker, push-button etc.)

Specialist required

ATTENTION

AWAG Elektrotechnik AG Sandbüelstrasse 2 CH-8604 Volketswil
Tel. +41 44 908 19 19 Fax +41 44 908 19 99 [email protected] www.awag.ch

9100061.docx / 1876214
SW: miniS01_V200116 / 27.01.2020 Seite 4 / 4