Loading manuals...

ENS UV Cleaning Touch Screen Monitor Manual


ENS UV Cleaning Touch Screen Monitor Manual Image

UV-SA
367-5455
INSTALLATION INSTRUCTIONS

Check List for Quick Set-Up 

  • Attach bracketry according to instructions found in this guide. See contents below.
  • Attach the power cable to the circular jack 4 on the back of the UV-Clean unit.
  • Power the device by plugging in the opposite end of the power cable to the supplied adapter, or another USB 3.0
    a device with an output power of 900 mA.
  • Set-up is complete.

SAFETY and DISPOSAL

Appropriate use of this product is expected and is the responsibility of the purchaser of this product.
This product uses UV-C light. Eyes and skin should be kept from exposure.
Eye inflammaon and skin irritation can occur from prolonged exposure. For sensitive skin, burns may occur.
Do not touch the glass UV bulb surface. Fingerprints create a barrier and reduce UV ability.

Do not use this device on people, food, or pets.
Keep out of reach of children. This product is not a toy.
Do not attempt to disassemble this product. Nor is it serviceable. The warranty will be void.
This UV bulb contains mercury in very small amounts. Precautions should be used to prevent breakage.
Mercury may cause injury if swallowed and is known to cause reproductive harm.
Dispose of this product responsibly per regulations.
Do not expose this product to water, liquids, or moisture. Electricity is present.
UV-C can discolor materials such as plastic and fabric over a period of me.

UV Bulb
Breakage: All visible bulb components should be culinarily swept into a sealable bag, box or jar and taken outdoors.
Caution: The UV bulb contains a very small amount of mercury.
As suggested by the EPA, do not vacuum up broken glass unless it is the only remaining debris. The same steps used to clean up common CFLs may be used for this UV bulb.
As listed here: https://www.epa.gov/cfl/cleaning-broken-cfl

Recycling may be an option in your area. www.lamprecycle.org/state-local-laws
When done, this prevents mercury from entering the environment, and reuse of glass, and metal is possible.
Refuse collection can be handled by commercial waste contractors, municipalities, or other local household waste programs.

1. Status Indicator 2. Motion Sensor 3. Push Button For Task Light 4. Power Receptacle 5. Micro-USB
Data
Receptacle
White = On, Stand By
Blue = Cleaning
Blue Blink = Bulb Failure
Detection for UV auto shut-off feature Control the on/off
of the LED task Light
DC 5V supply
included, Smm jack
Retrieve cleaning cycle information stored internally

Internal Clock Barry

Battery disposal is controlled by law and requires proper acon.
Recycling and Refuse collection can be handled by commercial waste contractors, municipalities, or other local household waste programs.

Resources

Locate centers near you: search.earth911.com
EPA www.epa.gov
Federal Universal Waste Rule
www.lamprecycle.org
batteryresponsibility.org/battery-recycling

Maintenance

Do not attempt to service this product. Contact customer service at Proximity Systems for guidance.
Do not subject the bulb to fingerprints, solvents, or abrasion.
Cleaning the bulb with a damp cloth or lens ssue is advised when the unit is not plugged in and the device is at room temperature only.

Environmental Conditions for Operation Designed For

  1. Commercial, Indoor use only
  2. Altitude up to 3050m
  3. Working temperature: 20 – 27 degrees C (68-80 deg F). Humidity 20-90% (non-condensing).
    Storage temperature: -20 – 55 degrees C (-4-130 deg F). Humidity <85% (non-condensing).

UV-SA

Step 1:

Insert the power cable wire through the cable hole located near the top of the stand. Continue the cable down the back of the stand.

Step 2: Locate the pre-assembled portion

‘Level’ or, O degrees of rotation is recommended for this model.
As shown above.

The long screw holds a rotation position with a small amount of pressure.
Tighten until firm only.

Step 4:

UV-Clean
HOW IT WORKS

Cleaning
When positioned and plugged into power, your UV-Clean device will begin working.
It has pre-set operaon mes.
Cleaning cycles operate autonomously throughout the life of the product.
Moon-sensor technology pauses cleaning cycles and relays the need to run a cleaning cycle when people come and go.

Step 5:
Plug-In Power (supplied adapter or a USB 3.0.)

Operation Timing

Clean Time: The period of me the device is producing UV-C. Factory set to 3 minutes.
No Moon Time: The length of me the device will allow to pass before producing UV-C is the moon sensor has communicated an absence of movement. Factory set to 15 seconds.
Wait Time: Downtime scheduled between cleaning cycles that are unrelated to moon sensor activity.
Factory set to 60 minutes.

SHEET REV D /2020