PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE We recommend this fitting is installed by a qualified Electrician

IMPORTANT INFORMATION

  • Installation should be carried out in accordance with the latest edition of the IET Wiring Regulations (BS7671) and taking into consideration the latest Building Regulations. If in doubt, consult a qualified electrician.
  • Before commencing any installation or maintenance work, ensure electricity is switched off at the mains.
  • Please take note of the rated voltage for the fitting.
  • Please take note of the IP (Ingress Protection) rating of the fitting when deciding location.
  • Always allow sufficient slack in the supply cable in order to remove the fitting from its position for any future maintenance.
  • Please make sure you are safe when working at height.
  • Employ the latest safety regulations and procedures to ensure the safe installation of the fitting.

FEATURES

  • Dimmable
  • Push-fit (loop-in / loop-out) terminal block
  • 60° beam angle
  • 30, 60, 90 minute fire rated
  • Optional bezels available:
    (White / Satin Nickel / Chrome / Black)
  • LED Lifetime: 25,000 hours (L70/B50)
  • CRI: >80
  • Operating temperature: -15ºC to +40ºC

INSTALLATION INSTRUCTIONS

  1. elect the required position for the downlight. Beware of joists, water pipes and electric cables and then cut out the ceiling hole size indicated in the table below.
  2. Provide mains supply to the cut-out in the ceiling.
  3. Make sure the mains supply is switched off, before connecting any cables to the pre-fitted terminal block.
  4. To open the terminal block housing, push the two grippers forward (see Fig.1 on page 2).
  5. Connect the mains supply cable to the push-fit terminal block as follows: (see Fig.2 on page 2)
    LIVE – (Red or Brown) to Terminal Marked L
    NEUTRAL – (Black or Blue) to Terminal marked N
    EARTH – (Green/Yellow) to Terminal marked E
  6. The terminal block housing should be placed away from the downlight in the ceiling void.
  7. Push the downlight into the cut-out in the ceiling by folding the two spring arms back, the spring arms keep the downlight in place. Make sure that there are no trapped cables or insulation between the ceiling and trim of the fitting.
  8. Switch on the power to test. The downlight is now ready for use.

FRD – FIXED CCT

FRD – CCT COLOUR SELECT

Product Ref Watts Description Lumens CCT Weight (kg) H Ø Cutout Ø
(mm)
FFRDCC 5.5W LED FRD CCT Colour Select C/W White Bezel 450lm / 500lm / 500lm 3000K / 4000K / 6000K 0.229 60 84 70-75
FFRDWHWW 5.5W LED FRD, White 480lm 3000K 0.19 55 84 60-72
FFRDWHCW 5.5W LED FRD, White 500lm 4000K 0.19 55 84 60-72
FFRDSNWW 5.5W LED FRD, C/W Satin Nickel Bezel 480lm 3000K 0.2 55 87 60-72
FFRDSNCW 5.5W LED FRD, C/W Satin Nickel Bezel 500lm 4000K 0.2 55 87 60-72
FFRDBWH White FRD Bezel 0.012 87
FFRDBSN Satin Nickel FRD Bezel 0.012 87
FFRDBCH Chrome FRD Bezel 0.012 87
FFRDBB Black FRD Bezel 0.012 87

220-240V~50/60Hz:

FFRDCC / FFRDWHWW / FFRDWHCW / FFRDSNWW / FFRDSNCW

FFRDCC ONLY – CCT COLOUR SELECT FUNCTION

  • CCT colour select function (WW/CW/DL)
  • Lumen output: 450lm (3000K) WW
    500lm (4000K) CW
    500lm (6000K) DL

To change the colour temperature, switch off the mains supply.
Carefully remove the Twist & Lock bezel from the fitting to reveal the CCT switch (see Fig.3). Move the switch to your desired colour temperature, then refit the bezel.
Switch the power back on, the downlight is now ready for use.

Fig 1.

Fig2.

Fig 3.

Fig 4.

CHANGING THE BEZELS
FFRDCC : To fit the bezel, align the locking teeth, then push and twist.
To remove the bezel, simply twist and pull.

FFRDWHWW FFRDWHCW FFRDSNWW FFRDSNCW

To fit the bezel, push and fit into place.
To remove the bezel, simply pull and un-clip from the trim.