Loading manuals...

HOMEWORKS Designer RF Maestro Local Controls Manual


HOMEWORKS Designer RF Maestro Local Controls Manual Image

product specifications
369305i

HomeWorks Designer RF Maestro Local Controls

Dimmer Switch Fan Speed Remote Dimmer Remote Switch

HomeWorks RF Maestro local controls function much like standard dimmers and switches but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where single circuits of lighting need to be dimmed or switched. Local fan speed controls are useful in locations where control of a single ceiling paddle fan is needed.
HomeWorks RF Maestro dimmers incorporate advanced features such as fade on / fade off, delayed long fade to off, and rapid full-on.
HomeWorks RF Maestro local controls include a Front Accessible Service Switch  (FASS) for safe lamp replacement. HomeWorks RF Maestro local controls install in single-pole or multi-location applications.  Remote dimmers/switches are available for multilocation control. Use Lutron Designer (Claro or Satin Colors) wallplates or designer-style wallplates from other manufacturers. Wallplates are sold separately. Lutron Claro and Satin Colors wallplates snap on with no visible means of attachment. HomeWorks RF Maestro local controls support color change kits.

Model Numbers

Dimmers
HQRD-6CL-XX
HQRD-6D-XX
HQRD-6ND-XX
HQRD-10D-XX
HQRD-10ND-XX
HQRD-6NA-XX
HQRD-F6AN-DV-XX HQRD-PRO-XX
600 W / VA (Incandescent / Halogen / MLV) or 150 W (CFL / LED)
Two-Wire Dimmer*
600 W Two-Wire Dimmer
600 W Neutral Wire Dimmer
1000 W Two-Wire Dimmer
1000 W Neutral Wire Dimmer
600 W Neutral Phase Adaptive Dimmer
6 A Fluorescent / LED 3-Wire Dimmer
250 W (CFL  / LED) or 500 W / VA Incandescent / Halogen / ELV or 400 VA MLVPhase Selectable, Neutral Optional dimmer*
Switches
HQRD-8ANS-XX
HQRD-8S-DV-XX
Neutral Wire Electronic Switch
Two-Wire Electronic Switch
Neutral Wire Electronic Switch
Two-Wire Electronic Switch
HQRD-2ANF-XX 2 A Fan Speed Control
Remotes (for multi-location installations)
HQD-RD-XX
HQD-RS-XX
HQD-RD-277-XX
HQD-RS-277-XX
Remote Dimmer (120 V~)
Remote Switch (120 V~)
Remote Dimmer (277 V~) (for use with -F6AN-DV only)
Remote Switch (277 V~) (for use with -8S-DV only)
Color Change Kits
RK-D-XX
RK-S-XX
RK-AD-XX
RK-AS-XX
RK-F-XX
Dimmers (-6CL, -6D, -10D, -10ND, -6NA, -PRO, -F6AN-DV)
Switches (-8ANS and -8S-DV)
Remote Dimmer (-RD)
Remote Switch (-RS)
Fan Speed Control (-2ANF)

* Go to www.lutron.com/ledfinder to see all compatible CFL / LED lamps.
Note: “XX” in the model number represents color/finish code. See Colors and Finishes at end of the document.

Specifications

Model Numbers Dimmer: HQRD-6CL, HQRD-6D, HQRD-6ND, HQRD-10D, HQRD-10ND, HQRD-6NA, HQRD-F6AN-DV, HQRD-PRO
Switch: HQRD-8ANS, HQRD-8S-DV
Fan Speed Control: HQRD-2ANF
Remote: HQD-RD, HQD-RS, HQD-RD-277, HQD-RS-277
Color Change Kits: RK-D, RK-S, RK-AD, RK-AS
Power 120 V~ 50 / 60 Hz: -6CL,-6D, -10D, -10ND, -6NA, -2ANF, -8ANS, -RD, -PRO, -RS
120 – 277 V~ 50 / 60 Hz: -F6AN-DV, -8S-DV
Typical Power Consumption Dimmer / Switch / Fan Speed Control: 0.6 W
Test conditions: load is off and nightlight mode is enabled.
Remote Dimmer / Switch: 0 W Test conditions: load is off.
Regulatory Approvals UL, CSA (all except -6CL, -6NA and -PRO), cUL (-6CL, -6NA, -PRO only), NOM, FCC, IC,
COFETEL, ANATEL (all except -6NA, -6CL, and remotes)
Environment Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only.
Communications Dimmers and switches communicate with the HomeWorks system through Radio Frequency (RF) and must be located within 30 ft (9 m) of a repeater. Remote dimmers/switches are not required to be within a specific range of a repeater.
ESD Protection Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.
Surge Protection Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits.
RTISS Equipped Circuitry compensates in real-time for incoming line-voltage variations (neutral connection required). -PRO only.
Power Failure Power failure memory: should power be interrupted, the control will return to its previous state when power is restored.
Mounting Requires a U.S. wallbox. 3½ in (89 mm) deep recommended 2¼ in (57 mm) deep minimum.
Wiring Use only remote dimmers (-RD / -RD-277) and remote switches (-RS / -RS-277) with dimmers / switches / fan speed controls. Up to 9 -RD / -RD-277 or -RS / -RS-277 may be used with controls.
Warranty warranty [PDF]

Design Features

Dimmer

  • On a single tap, lights fade ON or OFF.
  • On a double-tap, lights go to full ON.
  • When ON, press and hold the tap switch to engage the delayed long fade to OFF.
  •  Light levels can be fine-tuned by pressing and holding the dimming rocker until the desired light level is reached.
  •  Neutral and two-wire dimmers available.

Switch

  •  On a single tap, lights or motors turn ON or O F F.
  •  Neutral and two-wire switches available.

Fan Speed Control

  • On a single tap, the fan turns ON or OFF.
  • Fan speeds can be selected by pressing and holding the fan speed control rocker until the desired fan speed is reached.
  • Controls one paddle-type ceiling fan (Permanent split-capacitor motor) up to 2 A. Not for use with shaded-pole type motors (e.g., bath exhaust fans).
  • Provides 4 quiet speeds plus OFF.
  • Not for use with fans that have integrated fan speed and/or light control modules.
  • Requires a neutral connection.

Dimensions

All dimensions are shown as in (mm)HOMEWORKS Designer RF Maestro Local Controls

Mounting and Parts Identification

Ganging and Derating

When combining controls in the same wall box, derating is required (see Load Type and Capacity). No derating is required for remote dimmers, remote switches, or fan speed controls.

Load Type and Capacity

HQRD-6CL1
Incandescent/Halogen/CFL/LED see Mixing Lamp Types, page 9 No
MLV2,3 50 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA
HQRD-6D1
Incandescent/Halogen 50 W 600 W 500 W 400 W No
MLV2 50 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA
HQRD-6NA1,4
LED Varies5 150 W 150 W 150 W Yes
Incandescent/Halogen/ELV2 5 W 600 W 500 W 400 W
MLV 2,3 5 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA
HQRD-6ND1,4
LED Varies5 150 W 150 W 150 W Yes
Incandescent/Halogen 10 W 600 W 500 W 400 W
MLV 2,3 10 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA
HQRD-10D1
Incandescent/Halogen 50 W 1000 W 800 W 650 W No
MLV2 50 W/ VA 800 W/1000 VA 600 W/800 VA 500 W/650 VA
HQRD-10ND1,4
LED Varies5 150 W 150 W 150 W Yes
Incandescent/Halogen 10 W 1000 W 800 W 650 W
MLV2,3 10 W/ VA 800 W/1000 VA 600 W/800 VA 500 W/650 VA
  1. Dimmer Load Type:
    • -6D, -6ND,-10D, -10ND: designed for use with permanently installed incandescent, LED, magnetic low-voltage, or tungsten halogen only.
    • -6CL: designed for use with permanently installed incandescent, magnetic low-voltage, tungsten halogen, CFL, or LED only.
    • -6NA: designed for use with permanently installed incandescent, LED, electronic low-voltage, magnetic low-voltage, or tungsten halogen only.
    Note: Do not install dimmers to control receptacles or motor-operated appliances.
  2. Low-Voltage Applications: -6CL, -6D, -6ND, -10D -10ND: use with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers.
    Low-Voltage Applications: -6NA: use with electronic (solid-state) or magnetic (core and coil) transformers.
    Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following:
    • Do not operate low-voltage circuits without operative lamps in place.
    • Replace burned-out lamps as soon as possible.
    • Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent.
  3. Do not mix CFL or LED loads with MLV loads.
  4. Power Boosters / Load Interfaces: -6NA, -6ND and -10ND can be used to control power boosters/load interfaces. For a list of compatible power boosters/load interfaces see Compatible Power Boosters and  Load Interfaces, page 10.
  5. Minimum load depends on the lamp and is not limited to a particular wattage. Refer to the LED Product Selection Tool at www.lutron.com/ledtool

Load Type and Capacity (continued)

HQRD-PRO
LED 1 bulb 2 250 W 200 W 150 W Optional 1 Either
CFL 1 bulb 2 250 W 200 W 150 W Optional 1 Forward
MLV Transformer with LEDs See Application Note #559 (P/N 048559) at www.lutron.com No Derating Required Required Forward
ELV Transformer with LEDs Reverse
MLV Transformer with Halogen 10 W 400 VA

(300 W)

No Derating Required Required Forward
ELV Transformer with Halogen 10 W 500 W 400 W 300 W Required Reverse
Incandescent / Halogen 5 W 2 500 W 400 W 300 W Optional 1 Either
Dimmable Fluorescent Ballast 1 ballast 3.3 A (400 VA) No Derating Required Required Forward
Hi-lume 1% 2-wire (LTE) LED Driver 1 driver 3.3 A (400 W)

20 drivers max.

No Derating Required Required Forward
PHPM-PA / 3F and GRX-TVI 3 1 interface 3 interfaces No Derating Required Required Forward
  1. Neutral is recommended for best dimming performance, if available, but is not required for this load type.
  2. The minimum load shown is for neutral connected operation. If no neutral is used, the minimum load is
    2 bulbs LED/CFL, or 25 W Incandescent / Halogen.
  3. Power Boosters / Load Interfaces: -HQRD-PRO can be used to control power boosters/load interfaces. For a list of compatible power boosters/load interfaces see Compatible Power Boosters and Load  Interfaces, page 10.
    Note: For dimming MLV fixtures, the maximum lamp wattage is typically 70%–85% of the transformer’s VA rating. For actual transformer efficiency, contact the manufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the dimmer.

HQRD-F6AN-DV 1,2,3
Fluorescent/LED Drivers 0.05 A 6 A 5 A 3.5 A Yes
1 ballast 60 ballasts 50 ballasts 35 ballasts
HQRD-2ANF4
Ceiling Fan 0.083 A 2 A 2 A 2 A Yes
HQRD-8ANS 1,5
Lighting 10 W 8 A 6.5 A 5 A Yes
Motor 0.08 A 1/4 HP 5.8 A 1/4 HP 5.8 A 1/6 HP 4.4 A
HQRD-8S-DV5,6
Lighting 40 W/ VA 8 A 8 A (2-gang);

7 A (3-gang)

7 A No
Motor 0.4 A 1/10 HP 3 A

Note: Do not install dimmers to control receptacles or motor-operated appliances.

  1. Power Boosters / Load Interfaces: -F6AN-DV and -8ANS can be used to control power boosters/load interfaces. For a list of compatible power boosters/load interfaces see Compatible Power Boosters and Load  Interfaces, page 10.
  2. Fluorescent Dimmer Load Type: -F6AN-DV: designed for use with permanently installed 3-wire 120 V~ or 277 V~ line voltage control fluorescent ballasts or LED drivers. Use with only Hi-lume, Hi-lume 3D, Hi-Lume  Compact SE, Eco-10, or EcoSystem (H3D-, FDB-, ECO-,HL3-, EC5-, L3D). Do NOT use with any other ballasts or drivers. Do not install to control receptacles or motor-operated appliances.
  3. Maximum Load: The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS.
  4. Ceiling Fan Application: -2ANF
    • Use to control one paddle-type ceiling fan (permanent split-capacitor).
    • Use the ceiling fan’s pull chain to set its speed to the highest setting.
    • Do not use to control fans that use shaded-pole motors (e.g., bath exhaust fans).
    • Do not use to control fans that have integrated fan speed controls (e.g., fans that have a remote control), unless the integrated control is removed from the ceiling fan.
    • Do not connect to any other motor-operated appliance or to any lighting load type.
    • Do not use to control a fan lighting load (e.g., light kit).
  5. Switch Load Type:
    • -8ANS and -8S-DV: designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, tungsten halogen, fluorescent, CFL, LED, or motor loads.
    • -8S-DV can also be used with permanently installed 277 V~ magnetic low-voltage or fluorescent loads.
  6. Shunt Capacitor: Some -8S-DV installations may require the use of a shunt capacitor; this is especially necessary for load types sensitive to leakage current (e.g., fluorescent ballasts). If load flickers, install a  shunt capacitor. An optional shunt capacitor must be installed inside the loading fixture or in a separate J-box.  For shunt, capacitor installation see Wiring Diagram 4, 9, or 10.

Mixing Lamp Types

Mixing lamp types (using a combination of CFL / LED, and Incandescent / Halogen bulbs) and ganging with other dimmers or electronic switches may reduce maximum wattage as shown in the chart below.
Example: If you have two dimmers ganged together and you have two 24 W bulbs installed (total CFL Wattage  = 48 W), on one dimmer, you may add up to 300 W of incandescent or halogen lighting to that one dimmer.  Repeat the exercise for the other dimmer with which it is ganged.

HQRD-6CL1,2
0 W + 50 W – 600 W Or 50 W – 500 W Or 50 W – 400 W No
1 W – 25 W + 0 W – 500 W Or 0 W – 400 W Or 0 W – 300 W
26 W – 50 W + 0 W – 400 W Or 0 W – 300 W Or 0 W – 200 W
51 W – 75 W + 0 W – 300 W Or 0 W – 200 W Or 0 W – 100 W
76 W – 100 W + 0 W – 200 W Or 0 W – 100 W Or 0 W – 50 W
101 W – 125 W + 0 W – 100 W Or 0 W – 50 W Or 0 W
126 W – 150 W + 0 W Or 0 W Or 0 W
HQRD-PRO3
0 W + 5 W3 – 500 W Or 5 W3 – 400 W Or 5 W3 – 300 W Optional
1 W – 50 W + 0 W – 400 W Or 0 W – 300 W Or 0 W – 200 W
51 W – 100 W + 0 W – 300 W Or 0 W – 200 W Or 0 W – 100 W
101 W – 150 W + 0 W – 200 W Or 0 W – 100 W Or 0 W
151 W – 200 W + 0 W – 100 W Or 0 W Or 0 W
201 W – 250 W + 0 W Or 0 W Or 0 W
  1. Dimmer Load Type -6CL is designed for use with permanently installed incandescent, CFL, LED, magnetic low-voltage, or tungsten
    halogen only. Do not install dimmers to control receptacles or motor-operated appliances.
  2. Do not mix CFL and LED loads with MLV loads.
  3.  The minimum load shown is for neutral connected operation. If no neutral is used, the minimum load is 2 bulbs CFL / LED or 25 W Incandescent / Halogen.

Compatible Power Boosters and Load Interfaces
Some local controls can be used to control power boosters or load interfaces. Up to three power boosters or load interfaces can be used with one control. See table below for a list of controls and compatible power boosters and load interfaces.

Control Phase Adaptive Power Modules: PHPM-PA-120-WH; PHPM-PA-DV-WH 3-wire Fluorescent Power Modules: PHPM-3F-120-WH; PHPM-3F-DV-WH Switched Power Module:

PHPM-SW-DV-WH

0 – 10 V- Interface and Switching Module: GRX-TVI
HQRD-6ND
HQRD-10ND
HQRD-6NA
HQRD-F6AN-DV1
HQRD-8ANS
HQRD-PRO

Only the GRX-TVI is compatible with the HQRD-F6AN-DV at 277 V~. All other power modules are 120 V~ only.

Operation

Wiring Diagrams

Wiring Diagram 1
Single-Location Installation without Neutral¹
-6CL, -6D, -10D, -PRO

Wiring Diagram 2
Single-Location Installation with Neutral¹
6ND, -10ND, -6NA, -2ANF, -8ANS, -PRO

Wiring Diagram 3
Single-Location Fluorescent Dimmer Installation¹
-F6AN-DV with Lutron Ballast / LED Driver

Wiring Diagram 4
Single-Location 2-Wire Switch Installation¹
-8S-DV with Optional Shunt Capacitor²

Note: Bolded lines in diagrams indicate leads on products.
When using controls in single-location installations, tighten the blue terminal. Do not connect the blue terminal to any other wiring or to the ground.
Optional Shunt Capacitor must be installed inside the loading fixture or in a separate J-box.
Wiring Diagram 5
Multi-Location Installation without Neutral¹
-6CL, -6D, -10D, and -PRO with HQD-RD

Wiring Diagram 6
Multi-Location Installation with Neutral¹,²
-6ND, -10ND, -6NA, -2ANF and -PRO with HQD-RD; -8ANS with HQD-RS

Note: Bolded lines in diagrams indicate leads on products.

  1. Up to 9 Remote Dimmers/Remote Switches may be connected to the Dimmer / Switch / Fan Speed Controls. Total blue terminal wire length may be up to 250 ft (76 m), except -PRO which is up to 150 ft (45 m).
  2. Neutral-Wire Dimmers / Switches / Fan Speed Controls must be connected on the Load side of a multi-location installation, except the -PRO which can be connected in any position.

Wiring Diagram 7
Multi-Location Fluorescent Dimmer Installation¹,²(120 V~)
-F6AN with HQD-RD and Lutron Ballast / LED Driver

Wiring Diagram 8
Multi-Location Fluorescent Dimmer Installation¹,²(277 V~)
-F6AN with HQD-RD-277 and Lutron Ballast / LED Driver

Note: Bolded lines in diagrams indicate leads on products.

  1. Up to 9 Remote Dimmers / Remote Switches may be connected to the Dimmer / Switch / Fan Speed Controls. Total blue terminal wire length may be up to 250 ft (76 m), except for -PRO, which is up to 150ft (45 m).
  2. Neutral-Wire Dimmers / Switches / Fan Speed Controls must be connected on the Load side of a multi-location installation, except the -PRO, which can be connected in any position.

Wiring Diagram 9
Multi-Location 2-Wire Switch Installation¹(120 V~)
-8S-DV with HQD-RS and Optional Shunt Capacitor

Wiring Diagram 10
Multi-Location 2-Wire Switch Installation¹(277 V~)
-8S-DV with HQD-RS-277 and Optional Shunt CapacitorNote: Bolded lines in diagrams indicate leads on products.

  1. Up to 9 Remote Dimmers / Remote Switches may be connected to the Dimmer / Switch / Fan Speed Controls. Total blue terminal wire length may be up to 250 ft (76 m), except for -PRO which is 150 ft (45 m).
  2. Optional Shunt Capacitor must be installed inside the load fixture or in a separate J-box. Shunt capacitor (LUT-MLC) is included with 8S-DV.

Colors and Finishes

  • Due to printing limitations, the colors and finishes shown cannot be guaranteed to perfectly match actual product colors.
  • Color chip keychains are available for more precise color matching:
    Gloss Finishes: DG-CK-1
    Satin Finishes: SC-CK-1

For the latest color offerings see our website: http://www.lutron.com/satincolors

Metal Finish (wallplate only)
When using Stainless Steel wallplates, it is recommended that you order the control at Midnight (MN).

Lutron, Claro, Hi-Lume Compact SE, Eco-10, EcoSystem, FASS, Hi-Lume, HomeWorks, Maestro, and Satin Colors are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries.
All other product names, logos, and brands are the property of their respective owners. www.lutron.com/support

Customer Assistance:
1.844.LUTRON1 (U.S.A. / Canada)