SOLEUSAIR Portable Air Conditioner
SOLEUSAIR Portable Air Conditioner
Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner’s Manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner.
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.
- Always place the unit on a level surface.
- Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.
- Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or outlet grilles.
- The unit must be connected to a correctly grounded power supply.
- Do not start or stop the unit by inserting or pulling out the power plug.
- Do not use an adapter plug or extension cord.
- Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
- Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.
- Do not let children play near this unit.
- Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.
- When cleaning the unit, always turn the unit off and unplug the power cord.
- Do not mix old and new batteries in the remote control.
PACKAGE CONTENTS
- Portable Air Conditioner (1)
- Exhaust Hose (1)
- Exhaust Hose Connector (1)
- Window Kit Panel (3)
- Window Kit Adapter (1)
- Wing Nut (2)
- Optional Drain Tube (1)
- Drain Tube Stopper (1)
- Remote Control (1)
- AAA Battery (2)
- Owner’s Manual (1)
- Optional Window Security Pack (1)
SPECIFICATIONS
Model Number | PSR-06-01 | PSR-08-01 | PSR-10-01 |
Cooling Capacity | 6,000 BTU/Hr | 8,000 BTU/Hr | 10,000 BTU/Hr |
Dehumidification | 76 pts/Day | 101 pts/Day | 116 pts/Day |
Cooling Power Usage | 704 Watts
6.2 Amps |
938 Watts
8.9 Amps |
1172 Watts
10.2 Amps |
Air Flow (High/Low) | 205/164 CFM | 205/164CFM | 205/164 CFM |
Power Source | 115 V / 60 HZ | 115 V / 60 HZ | 115 V / 60 HZ |
Noise Level dB(A) | 53-55 dB | 53-55 dB | 53-55 dB |
Product Weight | 49.6 Lbs. | 49.6 Lbs. | 49.6 Lbs. |
Operating Temperature | 61℉-88℉ | 61℉-88℉ | 61℉-88℉ |
Product Dimension (W x H x D) | 12.25”×29.87”
×13.25” |
12.25”×29.87”
×13.25” |
12.25”×29.87”
×13.25” |
Refrigerant | R-410A | R-410A | R-410A |
- The cooling capacity is measured at an ambient temperature of DB 95˚F, WB 83 ˚F.
- Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
- Power consumption is measured when the fan runs at the highest speed setting.
- These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
- If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature, the air conditioner may not work properly.
POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
- Plug power cord into wall outlet, the LED light will turn on.
- Press TEST Button, circuit should trip, cutting power to the air conditioner. When this occurs, the LED light will turn off.
- Press RESET button to restore power to the unit. Once power is restored, the LED light will turn on again.
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus N.A. Customer Service for troubleshooting recommendations.
WARNING:
- DO NOT press the TEST button while the air conditioner is operating.
- The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
- The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
- The cord and plug are intended for indoor use only.
PRODUCT DIAGRAM
- Control Panel
- Manual Control Louver & Air Outlet
- Carry Handle
- Caster
- Air Filter
- Air Filter
- Hot Air Discharge Opening
- Air Intake Grille
- Condensation Drain Hole
- Exhaust Hose
- Exhaust Hose Connector
- Window Kit Adapter
- Window Kit Panels
- Wing Nuts
- Optional Drain Tube
- Drain Tube Stopper
- Remote Control
- Batteries
- Optional Window Security Pack
PARTS and ASSEMBLY
ASSEMBLY and INSTALLATION
When the unit is operating in air conditioning mode, the unit draws in indoor air and exhausts hot air out of the room to complete the air exchange. The Window Kit must be installed when operating the unit in air conditioning, dehumidification.
When the unit is operating in Fan Mode, no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan.
The supplied window kit can be installed in sliding windows and sliding glass doors up to 7 ft. long (approximate length). When installed, be sure to keep the exhaust hose and short and straight as possible for maximum efficiency.
WINDOW KIT ASSEMBLY
WINDOW KIT INSTALLATION
PORTABLE AIR CONDITIONER
The window venting kit must be installed in order for the unit to work correctly. The window venting kit has been de-signed to fit into most vertical and horizontal window openings and sliding glass doors up to 7 feet..
- Open the window or door to adjust the length of the Window Kit Panels to fit the opening. If necessary, mark the kit and cut one end down to properly fit the opening
- Twist the Exhaust Hose Connector over the discharge opening on the back of the unit and extend the Exhaust Hose. (Keep the exhaust hose as short and straight as possible)
- Attach the Window Kit Adapter to the Exhaust Hose. Then attach the Window Kit Adapter to the Window Kit panel. Close the window or door tightly.
SECURITY BRACKET
Optional Security Bracket Installation
Your Window Kit also includes an optional security bracket that can be installed to prevent the window from being opened from the outside while a Window Kit is installed.
CONTROL PANEL
OPERATING INSTRUCTIONS FOR CONTROL PANEL BUTTONS
- Power On and Off – Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
- Mode Selection – Press the MODE Button repeatedly to cycle between the different modes: Air Conditioner (Cool) mode, Fan-only mode, Dehumidifier (Dry) mode, Sleep mode, and Auto mode. Each press of the MODE button will light up a different indicator on the control panel. The exhaust hose and window kit must be installed when the unit is in Air Conditioner, Dehumidifier mode, Auto mode, and Sleep mode. When using the unit as a fan, the window kit is not required.
- Temperature – Select the desired temperature by pressing either the ▲ or ▼ button when using the unit in Air Conditioner mode. The temperature indicator flashes to display the desired temperature set-ting. After the temperature is set, the unit will display this temperature setting until it is changed by the user. The temperature indicator display shows temperature in Fahrenheit. While the unit is plugged in, but not powered on, press and hold the▲ and▼ buttons for 3 seconds to switch between Celsius and Fahrenheit.
- Fan Speed – Press FAN SPEED button to choose fan speed in High, Medium or low.
- Timer – Press TIMER button to set the unit automatically turn ON or OFF. Use the ▲ and ▼buttons to program the hour increment.
- Turbo Cool – When Turbo Cool is activated, the unit will cool at 61°F on fan high for 10 minutes and then return to the original settings.
- Bucket Full – When the unit cannot evaporate the collected moisture fast enough, the excess water will collect in a backup water tank located inside the unit. The BUCKET FULL indicator will light up.
- Louver Direction – This unit has 2-way directional louvers. Use the louver guides manually to direct air up and down.
REMOTE CONTROL
- Power On and Off – When the unit is plugged in, press the POWER button to turn on the unit. Press the POWER button once more to turn the unit off. When in Air Conditioner mode, Auto mode, and Sleep mode, the selected temperature will appear on the remote control LCD display. When the unit is in Fan mode or Dehumidifier mode, no temperature will be displayed. This shows that temperature selection is not available when the unit is in Fan mode and Dehumidifier mode.
- Mode Selection – Press the MODE Button repeatedly to cycle between the different modes: Auto, Sleep, Air Conditioner, Dehumidifier, and Fan-Only mode. The mode icon on LCD display will light up showing which mode is selected.
- Fan Speed – Press the FAN HIGH, FAN MED, or FAN LOW button to choose desired fan speed. When the unit is in Dehumidifier mode, the fan speed cannot be changed. When Turbo Cool is activated, fan speed is automatically set on high and is not adjustable in this mode.
- Temperature Setting – When the unit is in Air Conditioner mode, you can select your desired temper-ature. Press the ▲ or ▼ to select your desired temperature setting. The temperature on the LCD dis-play on the remote control will increase or decrease accordingly. Pressing the °C /°F button will switch the temperature select between °C and °F.
- SLEEP MODE – When in air conditioning mode, press the SLEEP Button on the remote control, Sleep mode icon will show on the remote control LCD display. When in SLEEP mode, the fan will run on low to keep fan noise at a minimum. The temperature setting will gradually increase to 2°F above the origi-nal set temperature each of first 2 hours. The unit will keep operating the same temperature until the sleep mode is turned off.
- TIMER – Auto-On: Press the TIMER button when the unit is off to set up the Auto-on timer. The hour indicator on the LCD display will turn on. Press the TIMER buttons to set timer within 1-24 hours.
Auto-Off: Press the TIMER button when the unit is On to set up the Auto-off timer. The hour indicator on the LCD display will turn on, Press the TIMER buttons to set timer within 1-24 hours. To cancel the timer, press TIMER button until the timer mode is turned off. - TURBO COOL – Press the Turbo Cool button to activate Turbo Cool mode. The unit will cool at 61° F on fan high for 10 minutes and then return to the original settings. Fan speed is not adjustable in this mode.
NOTE: If Fan mode activates less than 3 minutes and switches to Turbo Cool, it will be a compressor pro-tection shut down, compressor will turn on again until the 3 minutes is topped off. - MY TEMP MODE – Press this button to change the thermostat sensor from the air conditioner to the remote control location. The air conditioner will cool the area at the location and set temperature of the remote control.
- CHILD LOCK– Press this button to lock/unlock the remote control buttons.
UNIT OPERATION
Air Conditioner Mode
- Install the exhaust hose and window kit properly (see pages 7&8).
- Plug the Power Cord into an electrical outlet.
- Turn on the unit by pressing the POWER button.
- Press the Mode button until the air conditioner mode indicator lights up on the control panel display.
- Press the ▲ or ▼until the desired room temperature appears on the control panel display. The tempera-ture ranges from 61˚F – 88˚F.
- Select the desired fan speed by pressing the FAN SPEED button.
NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency.
NOTE: When the unit is running on air conditioning mode, the exhaust hose is required and must be vented outside using the supplied window kit.
Dehumidifier Mode
- Install the exhaust hose and window kit properly (see pages 7&8).
- Plug the Power Cord into an electrical outlet.
- Turn on the unit by pressing the POWER Button.
- Press the MODE button until the dehumidifier mode indicator lights up on the control panel display.
NOTE: The unit operates at low fan speed during dehumidifier mode. The unit cools room slightly during the dehumidification process. Keep the windows and doors closed to aid the effectiveness of the unit in removing the moisture from the room.
NOTE: When the unit is running on dehumidifier mode, the exhaust hose is required and must be vented outside using the supplied window kit.
NOTE: The unit will not perform in dehumidifier mode when the room temperature is lower than 50˚F .
UNIT OPERATION
Auto Mode
- Install the exhaust hose and window kit properly (see pages 7&8).
- Plug the Power Cord into an electrical outlet.
- Turn on the unit by pressing the POWER button.
- Press the MODE button until the Auto mode indicator lights up on the control panel display.
Auto Mode will operate the unit in air conditioning mode when the temperature is above 72 degrees, Fan mode when the temperature is below 72 degrees.
Sleep Mode
- Install the exhaust hose and window kit properly (see pages 7&8).
- Plug the Power Cord into an electrical outlet.
- Turn on the unit by pressing the POWER button on the control panel.
- Press the MODE button until the sleep mode indicator lights up on the control panel display.
NOTE: When in SLEEP mode, the fan will run on low to keep fan noise at a minimum. The temperature setting will gradually increase to 2°F above the original set temperature each of first 2 hours. The unit will keep operating the same temperature until the sleep mode is turned off.
Fan Mode
- Plug the Power Cord into an electrical outlet.
- Turn on the unit by pressing the POWER button on the control panel.
- Press the MODE button until the fan mode indicator lights up on the control panel display.
- Select the fan speed by pressing the FAN SPEED button.
NOTE: It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan mode.
Bucket Full Indicator
When the Internal Water Tank is full, the Bucket Full light will illuminate and the unit will automatically shut down. The air conditioner will resume normal operation once Internal Water Tank is emptied.
Internal Water Tank
When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an internal water tank inside the unit. The internal water tank holds approximately 1.5 liters of water. When this tanks becomes full, the unit will automatically shutdown and illuminate the Bucket Full indicator.
MAINTENANCE
HOW TO DRAIN THE INTERNAL WATER TANK
You will need a small pan, approximately 1” high to catch the water coming out of the water tank. Once the water tank is empty, the unit will resume operation within a few minutes.
- Do not move the unit when the water container is full. (Water will spill out)
- Place a small pan under the condensation drain hole on the bottom side of the unit.
- Remove the drain plug from the condensation drain hole. The condensate water will drain out automatically.
- When the drain pan is full, install the drain plug back onto the condensation drain hole to stop the water flow.
- Empty the drain pan.
- Repeat steps 2-5 until all the water is emptied.
NOTE: Once the condensate tank has been emptied, firmly press the drain plug back onto the condensation drain hole (Fig 15.1). It is not advised to use continuous drainage when the room temperature is higher than 90˚F.
NOTE: You may also use enclosed Optional Drain Tube to facilitate the draining process, make sure to re-plug the Drain Stopper once the condensation tank has been emptied (Fig 15.2).
NOTE: Make sure power is off and the power cord is not plugged into an electrical outlet prior to perform-ing any maintenance on the unit
- Clean or replace filter – If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed.
- Remove the filter from the filter compartment on the back of the unit.
- Wash the air filter by immersing it gently into warm water with a neutral detergent. Rinse the filter and dry it thoroughly out of sunlight.
- Slide the filter back into the filter compartment after it is thoroughly dried.
- If the filter is torn or unusable, order a new filter by calling the customer service number on the warranty page of this manual.
- Clean the unit Housing
- Keep the unit from being exposed directly to the sun to prevent color fading.
- Clean the surface with a damp cloth and dry it with a soft towel.
- Storing the Unit for an Extended Period of Time or Transporting the unit
- Empty any excess water by unplugging the drain plug in the back of the unit (located at the bot-tom).
- Unplug the unit.
- The unit should be stored in a cool dry place.
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER. SOLEUS N.A. HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
Air conditioner does not power on | • Unit is not plugged in
• No electric current to outlet • Internal safety device has tripped |
• Plug unit in.
• Check electric breaker box for a trip • Wait 30 minutes for safety de- vice to reset |
Air conditioner works for a limited amount of time | • There are bends in the exhaust hose
• Something is blocking the air from being discharged |
• Position the air exhaust hose correctly, keeping it as short and free of curves as possible
• Check and remove anything obstructing air discharge |
During operation, there is an unpleasant smell in the room | • Air filter is dirty | • Remove air filters, clean and re-install |
Air conditioner does not oper- ate after restarting the unit | • The internal compressor safety device prevents the unit from being restarted until three minutes have elapsed since it was last turned off | • Wait for compressor to turn on |
The control panel display shows Error codes | • The unit has a self diagnosis system to identify a number of malfunctions | • See page 18 Self-Diagnosis |
SELF-DIAGNOSIS CODES
SELF-DIAGNOSIS
The unit has a self diagnosis system to identify a number of malfunctions. Error codes are displayed on the appliance display.
Error Code | Possible Causes | Solution |
E2 | Indoor Temperature Sensor Failure | Turn the unit on and off to remove error code. If this code appears again, please call customer service at (877)-665-9765 |
E3 | Coil Pipe Sensor Failure | Please call customer service at (877)-665-9765 |
E4 | Fan motor Failure Refrigerant low | Unit shuts off, please call customer service at (877)-665-9765 |
LIMITED WARRANTY
One Year Components Limited Warranty
Five Year Compressor Limited Warranty
Soleus N.A. warrants the accompanying Soleus N.A. Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year for components and FIVE (5) years for the compressor from the date of original retail purchase in the United States.
If the unit exhibits a defect in normal use, Soleus N.A. will, at its option, either repair or replace it, free of charge within a reasonable time after the unit is returned during the warranty period.
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a copy of the original purchase invoice.
THIS WARRANTY DOES NOT COVER:
- Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a de-fect in material or workmanship.
- Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provi-sions in the instructions.
- Damage to the finish of the case, or other appearance parts caused by wear.
- Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus N.A.
- Freight and Insurance cost for the warranty service.
- Filter and Accessories.
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS N.A DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS NA’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IM-PLIED WARRANTY WITH RESPECT TO THIS UNIT.
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, salvaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For Technical Support and Warranty Service
Please Call (877) 665-9765
www.soleusna.com
DOWNLOAD RESOURCES
- SOLEUSAIR Portable Air Conditioner [pdf] Instruction Manual Portable Air Conditioner, PSR-06-01, PSR-08-01, PSR-10-01
- Read more: https://manuals.plus/soleusair/portable-air-conditioner-manual-5#ixzz7d0HmORHy
FAQ’S
Is this portable air conditioner suitable for my room?
This air conditioner is suitable for rooms up to 400 square feet.
What kind of window can I install this air conditioner on?
You can install this air conditioner on a window with a width of 24 inches to 48 inches and a height of 28 inches to 48 inches.
How many people can the air conditioner cool?
This air conditioner can cool a room up to 400 square feet, so it is ideal for rooms with 1-3 people.
How long does it take to cool my room?
It takes 1-2 hours to cool your room down 10 degrees Fahrenheit.
How much noise does the unit make?
The unit makes about 55 decibels of noise, which is about the same as a quiet library.
Is the unit easy to install?
Yes, the installation process takes about 30 minutes and you don’t need any tools for it.
Do you have to drain water out of portable air conditioner?
Depending on the humidity in your space, you will need to drain your portable air conditioner as often as every 8 hours. However, you usually won’t need to drain your portable air conditioner this often. If you live in a dry area, then you will rarely need to drain your portable air conditioner.
Do all portable air conditioners have to vent out a window?
These AC units are like self-contained heat pumps: They collect heat from a room and send it somewhere else through an exhaust vent. But portable ACs don’t need to vent out a window, so long as you can find another way to send the heat outside.
What is the disadvantage of portable conditioner?
Some disadvantages of portable air conditioners include heavy units that are difficult to move, high noise levels, draining the water regularly and the limited cooling space the unit offers.
Why is my portable AC not cold?
If your AC is blowing cold air out of the top vent, but your room still isn’t getting cold, your room is probably too hot or too large for the heat capacity of your air conditioner. Remember that portable air conditioners can only cool the room size they’re advertised for in moderate outdoor heat.
How Much Electricity Does A Portable Air Conditioner Use?
Mid-sized portable air conditioners use an average of 2900 watts per hour. Particularly large units can exceed the electricity usage of even central air conditioners, expending about 4100 watts per hour.
Why is my portable AC so loud?
Unlike a split air conditioner, a portable air conditioner has everything in one casing. This means the compressor of the air conditioning, which is responsible for the noise, is built into the casing. This causes a lot of noise.
VIDEO
SOLEUSAIR Portable Air Conditioner
www://soleusair.com/