SPORTSMAN GEN4000DF Portable Dual-Fuel Generator
Step-By-Step Quick Start Guide To Using Your Generator
Remove Generator From Package
Add Oil Oil Type:
SAE10W-30 Oil (Must add BEFORE first use) Oil Capacity: 18.5 fluid oz
Because this generator includes Low Oil Shut Off, the generator will not start with low oil. Start out with 18.5 oz, then fill until almost overflowing.)
Add Fuel
If using Gasoline, add Unleaded gasoline only octane rating of 87 or higher. Maximum Capacity: 3.6 Gallon gasoline fuel tank
If using Propane, connect Regulator Hose to Propane Tank and the LP Gas Inlet on Generator.
Start The Generator
- Use the generator OUTDOORS in a WELL VENTILATED AREA. DO NOT CONNECT electrical devices until AFTER the generator is started.
- Turn Engine Switch to ON
- If using GASOLINE, Turn FUEL PETCOCK to ON (Figure A)
- If using PROPANE, connect Turn Tank Vale to ON (Figure B) Adjust the CHOKE to CLOSED/CHOKE position (Figure C) Start the generator manually with the Recoil (Pull) Start.
- Once the engine has started, GRADUALLY move the choke lever to the “RUN/OPEN” position until the engine levels off. Then let the engine run approximately 5 minutes BEFORE adding appliances or tools.
- You can now connect electrical devices.
POWERED BY UNLEADED GASOLINE OR PROPANE FUEL
GENERATOR SPECIFICATIONS:
- 7.0 HP Engine, 4 Stroke OHV
- Recoil Start
- 3.6 Gallon Fuel Tank
- Low Oil Shut Off
- AVR Automatic Voltage Regulation
- UL Listed Electrical Components
- Engine Shut Off Switch
- Circuit Breaker & Power Outlets
- 1 – 12V D/C Outlet
- 4 – 120V A/C Outlets
- 1 – 120V RV Outlet
- Complies with EPA emissions
- DO NOT use E85, gas/oil mix, or modify the engine to run on alternate fuels.
- Run time = 10 hours @ 50% load
- Decibel Rating < 69 db @ 0% load
- Warranty: 2 YEAR limited
SURGE WATTS / RUNNING WATTS MAY BE REDUCED BY 10% WHEN USING PROPANE FUEL VS USING GASOLINE.
- If you are using a generator 3,000 ft. above sea level, the generator may not function properly because of air flow getting through the carburetor.
- High Altitude Use: This generator is not recommended for high altitude use 3,000 ft. above sea level.
OIL IS NOT INCLUDED WITH THIS GENERATOR. IT IS SOLD SEPARATELY.
Read and understand instruction manual before using the generator.
ATTENTION
This generator includes a built-in Carbon Monoxide Warning Alert! The generator will automatically shut off if dangerous levels of Carbon Monoxide is detected.TOLL-FREE NATIONWIDE HELPLINE! 866-460-9436
POWERED BY UNLEADED GASOLINE OR PROPANE FUEL
DO NOT CONNECT electrical devices until AFTER the generator is started.
WARNING
IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE, DO NOT OPERATE THIS PRODUCT!
Always follow Warning labels placed on the generator, and read and follow all Warning labels included inside the Product Manual.
WARNING: NEVER use a generator inside a home or a garage, EVEN IF the doors and windows are open.
ONLY USE OUTSIDE and far away from windows, doors and vents leading into an enclosed area.
Using a generator indoors can kill you in minutes. The generator produces an exhaust that contains carbon monoxide. This is a poison you cannot see or smell.
Do not attach a chain or rope to secure the generator to a post as this can be difficult to remove in the event of an emergency.
NOTE: The indicator will light RED and the engine will shutdown if dangerous Carbon Monoxide levels are detected. The engine will not restart for 5 minutes. If an error in the carbon monoxide system is detected, the indicator will blink YELLOW and the engine will shut down for five minutes.