Loading manuals...

Thermostates Digital Thermostat Switch XY-WT01 Manual


Thermostates Digital Thermostat Switch XY-WT01 Manual Image

XY-WT01 Digital Thermostat Switch

Features:

Set Temperature –Set T; Backlash Temperature–Back T

  1. Heating Mode H:
    When Temperature ≤ Set T ­ Back T; Relay conduction, heating equipment begin to work; when temperature ≥ Set T, Relay disconnect, heating equipment stop work;
  2. Refrigeration mode C:
    When Temperature ≥ Set T+Back T; Relay conduction, refrigeration equipment begin to work; When Temperature ≤ Set T; Relay conduction, refrigeration equipment stop work;
  3. High-Temperature Alarm ALA
    When Temperature ≥ Alarm Temperature, The system opens the sound and light alarm and disconnects the relay, any key stops the sound light;
  4. Delay Start OPH:
    When a normal heating or refrigeration work is done, the system starts to time T, and only after the T ≥ OPH, the system can carry out the next round of heating or refrigeration work;
  5. Temperature Correction Function OFE(-10.0 ~ 10.0):
    The system will work for a long time and may have deviations that can be corrected by this function, Temperature = Measured + Calibration
  6. Parameter Remote Read/Set:
    The parameters such as setting temperature, backlash temperature, and temperature correction can be set through UART.
  7. Real-time Temperature Report:
    If the temperature reporting function is turned on, the product is transmitted to the terminal by the UART at 1s intervals, which facilitates data collection;
  8. Relay enable (default enable):
    If the relay is disabled, the relay remains disconnected;
  9. Restore Factory Settings:
    At the same time press the STOP, set key more than 3S, restore factory settings;

Working mode setting /backlash temperature :

  1. In the running interface, short press SET key, enter the Quick setting interface;
  2. After entering the Quick Setup interface, switch the parameters
  3. Through the UP DOWN key, modify the parameter value, support short press/long press;
  4. Long press SET to build more than 3S or continuous 6S without any key operation, exit quickly set the interface, and save parameters;

Alarm temperature/Delay Start /temperature correction:

  1. In the operating interface, long press SET more than 3s, enter the parameters to set the interface;
  2. Enter the parameter to set the interface, through the short press SET key to switch to set the parameters;
  3. Through the UP DOWN key, modify the parameter value, support short press/long press;
  4. Long press SET3s above or continuous 6S without any key operation, exit parameter set interface, and save parameters;

How to turn on high-temperature alarm (default off):

Enter the parameter setting interface, switch to the alarm parameter ALA, turn on or off the high-temperature alarm function by short pressing the STOP button, and if the high-temperature alarm function closes, ALA displays ‘—-‘ as a reminder;

How to turn on delay start (default 0ff):

Enter parameter setting interface, switch to alarm parameter OPH, turn on or off high-temperature alarm function by short Press STOP button if high-temperature alarm function closes, OPH show ‘—‘ to remind;

Serial Control (MCU UART)
Communication standards: 9600bpsData bits: 8
Stop Bits: 1
CRC: none
Flow control: none

CMD Description
Start start data upload
Stop stop data upload
Read Read the param setting
T: ON Temperature relay enable
T: OFF Temperature relay disable
H: ON Humidity relay enable
H: OFF Humidity relay disable
TS: XX.X Set start Temperature (-20.0-60.0)
TP: XX.X Set stop Temperature (-20.0-60.0)
HS: XX.X Set start Humidity (00.0100.0)
HP: XX.X Set stop Humidity (00.0100.0)
TC: XX.X Set Temperature Calibration (-10.0-10.0)
HC: XX.X Set Humidity Calibration (-10.0-10.0)

Product Name: digital temperature controller
Product model : XY-WT0O1
Power supply: DC6.0~30V
Temp range: -50°C~110°C ; «4 EEL xe) , ,
Control accuracy: 0.1°C
Measurement input: NTC10K/B3950
Refresh frequency : 0.5second
Output type: relay output 10A
Type of probe: L:0.5 meter of waterproof probe

Temperature range-20-110 ºC


More Manuals From Thermostates