Loading manuals...

VICKS V925P-A Digital Pacifier Thermometer Manual


VICKS V925P-A Digital Pacifier Thermometer Manual Image

VICKS V925P-A Digital Pacifier Thermometer User Manual

READ AND SAVE THESE INSTRUCTIONS

Congratulations on your purchase of the Vicks® Digital Pacifier Thermometer. Please read these instructions carefully to ensure accurate temperatures and safe operation. When used properly, this high quality product will give you years of accurate, dependable service.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: The Vicks Pacifier Thermometer is intended for use with children from birth to age 5.

  1. THIS UNIT IS A MEDICAL DEVICE and is not designed for use as a regular pacifier. Store out of reach of children. Do not let children play with the unit. TEMPERATURE SHOULD BE TAKEN UNDER ADULT SUPERVISION.
  2. Any pacifier wears out. TO PREVENT POSSIBLE CHOKING HAZARD, test the strength of the nipple by pulling on the bulb portion before each use.
  3. Examine the pacifier bulb before each use for cracks, tears, tackiness or other signs of wear. Discard a worn unit immediately.
  4. Components may be harmful if swallowed. Contact your physician immediately should this occur.
  5. FOR ORAL USE ONLY. Do not measure temperature at any other site.
  6. The thermometer nipple comes in one size (medium) intended to fit most mouth sizes. Please gauge your child’s mouth size and the nipple size prior to thermometer use. A child using a nipple that is too large has an increased risk of choking.
  7. Do not attempt to disassemble the unit. There are no user serviceable parts inside. The battery is not replaceable. When the battery is almost exhausted, the following symbol will appear in the display window () indicating the unit should be discarded. Do not use as a regular pacifier after the battery is discharged. To protect the environment, dispose of the thermometer at appropriate collection sites according to national or local regulations. Keep out of reach of young children, elderly and pets.
  8. Do not wash the unit with any thinner or chemical solvent.
  9. Do not store unit in direct sunlight or at high temperature.

Overview

TEMPERATURE READINGS

This pacifier is for oral use only. Oral temperature readings are often approximately 0.2°F lower than rectal readings and 0.9°F higher than axillary (under the arm) readings.

Temperature readings vary from child to child. Although there is no singular ‘normal’ temperature reading, a temperature taken orally ranging between 97°F and 100°F is considered normal. Your child’s physician should be consulted to determine what temperature range the physician considers to be normal.

The best method to determine your child’s normal temperature is to use the thermometer when the child is feeling well. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate a normal body temperature.

OPERATING YOUR VICKS PACIFIER THERMOMETER:

  1. Press the power button. The display will read (188.8 ) confirming that the display is working.
  2. If you hold the on/off button, the unit will display the last temperature reading.
  3. Release the power button and the display will show L°F with °F flashing. When the temperature reading reaches 90.0°F or more, the display will show an actual temperature.
  4. Position the pacifier bulb in child’s mouth. Note: Drinking or eating prior to use may affect reading. Measurement should be taken one half hour after eating or drinking.
  5. Once the degree sign (°F) on the display has stopped flashing (approx. 2 minutes), the beeper will sound 10 times, indicating that the temperature is ready to read. This reading reflects the oral temperature of the child.
    Note It is recommended that the thermometer be left in the child’s mouth for 6-8 minutes to allow the nipple to warm up and to obtain a more accurate reading. This is required if the child does not pacify without interruption.
  6. Press the power button to turn the unit off. In the event that you forget, the thermometer will automatically turn off after 10 minutes.
  7. Repeat this procedure as necessary if pacifying is interrupted during use.

TO RECALL THE LAST TEMPERATURE:

  1. Press and hold the power button while turning on the unit. The last measured temperature will be shown in the LCD display with the letter “M” shown under the degree sign in approximately 3 seconds.
  2. Release the power button. The thermometer will be in “ready-to-measure” mode and the recalled temperature will be erased. Note: If the device is switched off before completion of temperature taking, L°F will appear in memory the next time the unit is used.

CLEANING INSTRUCTIONS:

  1. Clean the pacifier thermometer by wiping it with soap and warm water or rubbing alcohol (70% isopropyl alcohol).
  2. Wipe dry with soft cloth. Cover thermometer with the storage case included and store in dry location.
  3. Store your thermometer in a dry location free from dust and contamination and away from direct sunlight.
    Note Do not boil or clean in a dishwasher. This will cause the thermometer to no longer function and will void the warranty. Do not wash the unit with any thinner or chemical solvent.

SPECIFICATIONS:

Battery Life More than 200 hours of continuous operation. Test Protocol (Laboratory use only)
Accuracy +/-0.2°F between 98.0-102.0°F at room temperature of 71°F. Place thermometer into a stable liquid bath with a temperature set above 95°F. The nipple of the thermometer should be approximately 2cm below the surface.
Temperature Range 90.0° – 109.0°F. If less that 90.0°F an “L” is displayed. If more than 109.0°F an “H” is displayed. Wait for 90 seconds, then turn thermometer on by pressing the blue On / Off button. The thermometer is now in standard mode.
Beeper Unit will beep for approximately 8 seconds when peak temperature is reached. When the measurement is completed (approximately 2 minutes), record the temperature reading.

ONE YEAR LIMITED WARRANTY:

You should first read all Instructions before attempting to use this product.

  1. This 1 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
  2. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship.
  3. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

Call us toll-free at 1-800-477-0457 or e-mail: [email protected].
Please be sure to specify a model number.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

© 2016 All rights reserved.
Kaz USA, Inc., a Helen of Troy Company, Marlborough, MA 01752

This product is distributed under license from The Procter & Gamble Company. VICKS and other associated trademarks are owned by The Procter & Gamble Company
Visit: www.kaz.com
Printed in China

Helen of Troy

CREATIVE DEPARTMENT ARTWORK SPECIFICATIONS

  • Brand: Vicks
  • Category: Owners Manual
  • Models: V925P-A-V
  • Die Line Part #: NA
  • Oracle Desc. : OWNER’S MANUAL,KAZ Artwork,
    V925P-A-V
  • Subject: owners manual
  • Region: US
  • Size: IN: W4.75 x H7.375
    MM: W120.65 x H187.45
  • Scale: 1/1
  • Material: 45# Matte Text
  • Page count: NA
  • Revision: 4
  • Date: 24MAR16
  • Release Date: 28MAR16
  • Rerelease Date:

Colors:

Dielines (Do not print) / Spot Colors

Coating: Overall Gloss

Varnish: Spot UV

Special Instructions:

Quality Requirement of Artwork and Quality Clarification Process of Artwork Printing: Meet Eng-QS-06&02

Kaz USA, Inc., a Helen of Troy Company
Creative Services
Marlborough, MA 01752, USA
+1 508 490 7000



More Manuals From Vicks