Loading manuals...

Z-Wave PLUS EVA LOGIK Smart Dimmer Switch S2 Manual


Z-Wave PLUS EVA LOGIK Smart Dimmer Switch S2 Manual Image

Z-Wave PLUS EVA LOGIK Smart Dimmer Switch

Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may caus harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body

IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

DECLARATION DE CONFORMITE D’INDUSTRIE CANADA

WARRANTY

Evalogik Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product.

This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you.

This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS

Model: ZW31
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.
Maximum Loads: 500W, 2-gang 400W or 3-gang 300W incandescent, 100W CFL/LED
Range: Up to 100 feet line of sight between the Wireless Controller and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
For Ourdoor use
Specifications subject to change without notice due to continuing product improvement

WARNING

  • RISK OF FIRE
  • RISK OF ELECTRICAL SHOCK
  • RISK OF BURNS
  • CONTROLLING APPLIANCES:
    EXERCISE EXTREME CAUTION WHEN USING Z-Wave DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT
    ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
    THE FOLLOWING:
  • DO NOT USE Z-Wave DEVICES TO CONTROL ELECTRIC
  • HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
  • A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Introduction:

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
ZW31 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product. The Device Type of the ZW31 is Dimmer power switch.
The Role Type of the ZW31 is Always On Slave Role Type

Key Features:

  • Remote ON/OFF control via the Z-Wave controller
  • Manual ON/OFF control with the front panel push button
  • Support Association Group and Auto Report switch status
  • Support firmware upgrades via Over-the-air (need Gateways support)
  • Support Scenes

Product Overview:

  • A. Up Push button
  • B. Down Push button
  • C. Load (Black)
  • D. Lin (Black) – Line in
  • E. Nin (White) – Nutral in
  • F. 3-way (RED)

ZW31 Installation Wiring Diagram

Key function description

Function 1: Press the up or down button to turn the output ON or OFF
Function 2: Hold Dimmer Up or Dimmer Down
Function 3: Press the up or down button three times quickly to ADD and REMOVE
Function 4: Press the up or down button six times quickly to change Status LED Configuration
Function 5: When switch is off and quickly press UPPER paddle 2 times, switch turns on to 100% brightness
Function 6: Press click Z-Wave button 3 times quickly, and hold for at least 10 seconds at the third time to restore the device to the factory
(Node: Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Function 7: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 8: Tap B(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.

Led Indicate Function

  1. Flash two times
    When configuration parameter succeed LED flash two times
  2. quickly flash
    When inclusion or exclusion or reset, LED will quickly flash till operate complete

Z-Wave Remote Control
ADD or Remove the ZW31 from the existing Z-Wave home control network with your primary controller.

  • Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
  • When prompted by your primary controller, click the Up or Down button three times in one second.

Include ZW31 to/from a Z-Wave Gateway with supporting Security. The ZW31 can support the Primary Controller that implemented the security S2.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM Controller means “Remove” or “Exclusion”.

Z-Wave protocol Command Class Node Info

COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_CENTRAL_SCENE,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_FIRMWARE_UPDATE_MD

The Below listed Command Class are all supported the Security S2

COMMAND_CLASS_SWITCH_MULTILEVEL,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_CENTRAL_SCENE,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_FIRMWARE_UPDATE_MD

Support for Association Groups

ZW31 supports 2 association groups. Group 1 support 1 node ID,Group 2 Support maximum of 5 node ID’s Association group_1:Z-Wave Plus Lifeline

Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for ZW31 Status change report, 1. ZW31 will trigger AUTO report function if the Switch status had been changed.

Association group_2:basic set command
When the output of the ZW31 is changed, The ZW31 will automatically send out a related basic set command.

Restoring Factory Defaults

ZW31 is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.


More Manuals From Z-Wave Plus