Loading manuals...

Omron HEAT Pain Pro PM311 Manual


Omron HEAT Pain Pro PM311 Manual Image

Omron HEAT Pain Pro PM311Instruction Manual

INTRODUCTION

Thank you for purchasing the Omron® HEAT Pain ProTM Model PM311.
In order to use the unit safely, read the complete manual carefully before using the unit for the first time.
Keep this instruction manual in a convenient place or store with the unit for future reference.

  • Register your product on-line at www.register-omron.com.
  • Keep your purchase receipt as proof of purchase for warranty coverage.

This box contains the following components:

  • Main Unit
  • AC Adapter
  • 2 Pair of Gels
  • Cord with Pads
  • Pad Holder
  • Instruction Manual
  • Quick Start Guide with Pad Placement Guide

Intended Use

The Omron Heat Pain ProTM is intended for:
The relief of pain associated with sore or aching, muscles of the lower back, arms, legs, shoulder, or foot due to strain from exercise or normal household work activities.
Environments of Use: Clinics, hospital and home environments Patient Population: Adult

INSPECTION

Before using your unit, inspect to ensure that

  1. The cord is not broken.
  2. The gel is not damaged.
  3. The cord with pads connection is not broken.
  4. The unit is intact and working.

If there is any damage, consult Omron Healthcare Customer Service at 1-800-634-4350.

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INFORMATION

CONTRAINDICATIONS

Do not use this device if you have a cardiac pacemaker, implanted defibrillator, or other implanted metallic or electronic device. Such use could cause electric shock, burns, electrical interference, or death.

SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL

DANGER! Improper use may cause danger resulting in death or serious injury. These are situations in which the device should not be used.

WARNING! Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION! Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.

DANGER

Dispose of the battery according to applicable local government regulations

  • This rechargeable battery has been specifically designed for this product. Do not use it in any other devices.
  • Do not recharge this rechargeable battery once it has been removed from the main unit.
  • Do not dispose of battery in a fire.
  • Do not crush or puncture the battery because it may cause spontaneous flames.
  • Do not disassemble or modify it.
  • Do not connect the + and – poles using a piece of metal or other conductive objects.
  • Do not carry it or store it together with item such as necklaces and hair pins.
  • Do not recharge, use, or leave the battery in any high temperature environment such as in a location near a fire or in direct sunlight. Doing so may cause the battery to overheat, ignite or rupture.
  • Do not leave a battery that has been removed within reach of children or pets. Doing so may result in an injury or an accident. If liquid comes in contact with the battery, a fire or an accident may occur.

WARNINGS

  • Consult with your physician before using this device, because the device may cause lethal rhythm disturbances to the heart in susceptible individuals.
  • If you have had medical or physical treatment for your pain, consult with your physician before using this device.
  • If you are in the care of a physician, consult with your physician before using this device.
  • If your pain does not improve, becomes more than mild, or continues for more than five days, stop using the device and consult with your physician.
  • Do not place this device across your chest because the introduction of electrical current into the chest may cause rhythm disturbances to your heart, which could be lethal.
  • Do not place this device over open wounds or rashes, or over swollen, red, infected, or inflamed areas or skin eruptions (e.g., phlebitis, thrombophlebitis, varicose veins).

IMPORTANT SAFETY INFORMATION

  • Do not place the pads over your neck because this cause severe muscle spasms resulting in closure of your airway, difficulty in breathing, or adverse effects on heart rhythm or blood pressure.
  • Do not place this device on the head, the mouth, or any area of the face.
  • Do not place this device near the heart, or on genital area.
  • Do not place this device on both sides of the chest cavity simultaneously (lateral or front and back).
  • Do not place this device on both legs, such as calves at the same time because cardiac disturbance may occur.
  • Do not place this device on the bottom of both feet at the same time because cardiac disturbance may occur.
  • Do not use this device over, or in proximity to, cancerous lesions.
  • Do not use this device when in the bath or shower.
  • Do not use this device while sleeping.
  • Do not use this device on patients with paresthesia (abnormal sensation) or peripheral neuropathy (damage to your peripheral nerves that causes weakness, numbness, and pain).
  • Do not use this device while driving, operating machinery, or during any activity in which electrical stimulation can put you at risk of injury.
  • Do not use this device during exercise or while sweating.
  • Do not use this device together with a life-supporting medical electronic device such as an artificial heart or lung or respirator.
  • Do not use this device on infants, toddlers, or children because this device has not been evaluated for pediatric use.
  • Do not use this device on pregnant women.
  • Do not use this device on persons in capable of expressing their thoughts or intentions.
  • Do not use this device on persons who are unable to operate the unit by themselves.
  • Do not use this device on or near any other heating device, heating element such as a dryer or oven.
  • Do not use this device while using another TENS device.
  • Do not apply stimulation in the presence of electronic monitoring equipment (e.g., cardiac monitors, ECG alarms), which may not operate properly when the electrical stimulation device is in use.
  • Do not use this device with a heating pad.
  • Do not use this device under blanket.
  • Do not use heat on any muscle or joint which has swelling or edema. It may worsen the pain or condition.
  • Do not use over sensitive skin areas or in the presence of poor circulation.
  • If used on the elderly, use caution due to more sensitivity of the skin.
  • Do not bend or fold the pad with gels at any time.
  • The Pad can ONLY BE USED with the Gel.
  • The pad with gel should not come in contact with any liquid or water during therapy.
  • Apply pads only to normal, intact, clean, healthy skin (of adult patients).
  • This product has a built-in rechargeable battery. To prevent the risk of overheating, fire or explosion, do not throw into fire, apply heat, puncture or crush, use or leave in a high temperature environment.
  • For Hospitals and Clinics, simultaneous connection of a patient to a high frequency surgical medical equipment may result in burns at the site of the stimulator electrodes and possible damage to the stimulator.
  • If you suffer from any serious illness, consult your physician in order to confirm that it is advisable for you to use this Power Relief unit.
  • Use carefully. May cause serious burns.
  • The unattended use of this HV-PAD with PMGEL by infants, toddlers, children or incapacitated persons may be dangerous.
  • If the product feels too hot, stop use immediately.
  • For Hospitals and Clinics, operation in close proximity (e.g. 1 m) to a shortwave or microwave therapy ME equipment may produce instability to the stimulator output.

PRECAUTIONS

  • TENS is not effective for pain of central origin, including headache.
  • TENS is not a substitute for pain medications and other pain management therapies.
  • TENS devices have no curative value.
  • TENS is a symptomatic treatment and, as such, suppresses the sensation of pain that would otherwise serve as a protective mechanism.
  • Effectiveness is highly dependent upon patient selection by a practitioner qualified in the management of pain patients.
  • The long-term effects of electrical stimulation are unknown.
  • Since the effects of stimulation of the brain are unknown, stimulation should not be applied across your head and electrodes should not be placed on opposite sides of your head.
  • The safety of electrical stimulation during pregnancy has not been established.
  • You may experience skin irritation, redness or burning or hypersensitivity due to electrical stimulation, the gel or the heat.
  • If you experience any skin irritation or redness after a session, do not continue stimulation in that area of the skin.
  • If you have suspected or diagnosed heart disease, you should follow precautions recommended by your physician.
  • If you have suspected or diagnosed epilepsy, you should follow precautions recommended by your physician.
  • Use caution if you have a tendency to bleed internally, such as following an injury or fracture.
  • Consult with your physician prior to using the device after a recent surgical procedure because stimulation may disrupt the healing process.
  • Use caution if stimulation is applied over the menstruating or uterus.
  • Use caution if stimulation is applied over areas of skin that lack normal sensation.
  • Keep this device out of the reach of infants, toddlers, and children.
  • Use this device only with the cord with pads and accessories recommended by the manufacturer.
  • Place pads at least 1 inch apart for optimal result.
  • Do not use on wet skin (from sweating, bathing, high humidity).
  • Do not use this device for any other purpose except for what it is intended for.
  • Do not use this device without proper lighting. You may not be able to operate the unit successfully.
  • Do not use any another AC adapter other than the one provided in the Heat Pain ProTM packaging.
  • Do not share pads with another person. This may cause a skin irritation or infection. Pads are intended for use by one person.
  • Do not plug the cord into any device other than the Omron PM311.
  • Do not move the pads to another location while the unit is on.
  • Do not overlap pads or put pads on top of each other. It may weaken or stop therapy, or the unit may stop working. Gel pads may also stick together and cause gel to be removed when separating.
  • Do not leave pads attached to the skin after treatment.
  • Do not apply ointment or any solvent to the pads or to your skin because it will disrupt the pads from functioning properly. The self-adhesive pads will adhere to your skin.
  • Do not place this device in a room with high humidity, such as a bathroom. This will damage the unit. Ideal temperature for using +50 to +104 °F (+10 to +40 °C), 30 to 80 % relative humidity.
  • Do not insert the cord plug into any place other than the jack on the unit.
  • Do not pull on the cord during treatment.
  • Do not bend or pull the end of the cord.
  • No modification of the unit is allowed.
  • Therapy won’t work with just 1 pad. You MUST USE 2 PADS at the same time.
  • Make sure the components are connected well and the pads are fixed on the part of the body you wish to treat or the therapy may not be effective.
  • Pads should not touch any metal object, such as a belt buckle, necklace or other metal worn under clothing.
  • To avoid damage to the adhesive surface of the pads, only put the pads on the skin or the plastic pad holder.
  • Always place clean pads in accordance with illustrations provided (Refer to pages 21 – 25, Pad Placement).
  • If the unit is not functioning properly or you feel discomfort, immediately stop using the unit.
  • When pulling out the cord from the unit, hold the plug and pull.
  • Replace the cord when broken or damaged.
  • The size, shape and type of pads may affect the safety and effectiveness of electrical stimulation.
  • The electrical performance characteristics of pads may affect the safety and effectiveness of electrical stimulation.
  • Using pads that are too small or incorrectly applied could result in discomfort or skin burns.
  • The PADs do not work correctly without the GELs. For safety and effectiveness, they must be used together.
  • Before use, inspect the Cord with PADS and the cord for open wires or any damage. If damaged, do not use and replace immediately damaged cords and pads may cause skin burns or a fire.
  • Clean and dry affected area so it is free of all lotions/oils/sweat. The cord with pad and gel should be applied only to normal, intact, clean and healthy skin.

Adverse Reactions

  • You may experience skin irritation and burns beneath the stimulation electrodes applied to your skin.
  • You may experience headache and other painful sensations during or following the application of electrical stimulation near your eyes and to your head and face.
  • You should stop using the device and should consult with your physician if you experience adverse reactions from the device.
  • Do not use to treat one (1) region for extended periods of time (more than one 30 minutes a session, up to 3 times/day) or muscles in that region may become exhausted and sore.

HOW HEAT PAIN ProTM WORKS

What is it?

The OMRON® HEAT Pain ProTM is a portable unit that provides 2-in-1 relief, pain relief of TENS and comfort of HEAT. It is designed to reduce and relieve muscle and joint pain, stiffness and numbness in the back, arms, legs, shoulder and foot. The Heat Pain ProTM uses the PAD with GEL for the delivery of TENS therapy to the surface of the skin for pain relief.

Any of the modes can safely be used on body parts or pains described in this manual or Quick Start Guide/Pad Placement Guide. The Heat Pain ProTM can be successfully used in conjunction with any other pain treatment or medication.

This type of therapy, called Transcutaneous Electrical Nerve Stimulation (TENS), has been used for over 30 years by medical professionals such as physical therapists and chiropractors.

How does TENS and HEAT work?

Physical therapists have been using the combination of heat and TENS for decades. The HEAT warms the muscle for soothing comfort, and TENS provides pain relief.

TENS therapy suggests that electrical stimulation therapy may work in several ways:

  1. The gentle electrical pulses move through the skin to nearby nerves to block or shut out the pain message from ever reaching the brain from the source of the pain.
  2. The gentle electrical pulses increase the production of the body’s natural pain killer, such as endorphins.
  3. Furthermore, it is thought that the electrical stimulation improves blood circulation as well. Muscles contract and relax with the flow of the electrical stimulation. With repeated contracting and relaxing, the blood flows in and out and the blood circulation is improved.

KNOW YOUR UNIT

PACKAGE CONTENTS

KNOW YOUR UNIT

FEATURES

  1. 2 Heating modes, low or high, warms up the muscle.
  2. 3 therapy choices (COMBO 1, COMBO 2, TENS)
  3. 9 pre-set modes work with each therapy choice.
  4. 20 intensity levels (1 low to 20 high).
  5. Pair of Gels (durable, re-usable, up to 30 uses).
    (Only use OMRON® manufactured pads with gels with the unit).
  6. Automatic 30 minute shut off.
  7. Big screen lets you clearly control your therapy with mode, intensity level and minutes left.
  8. Low battery icon () displays to remind you to charge the unit.
  9. displays if the pad falls off.

BUTTONS AND THEIR FUNCTIONS

INSPECT UNIT AND RECHARGE BATTERY

Before using your unit, inspect these things.

  1. The cord is not broken.
  2. The gel is not damaged.
  3. The cord with pads connection is not broken.
  4. The unit is intact and working.

Before first time use:
We recommend charging the battery to a full 100 % charge.

After first time use:
Once fully charged, the battery will last for (4) 30 minutes uses on average. It takes about 5 hours to charge once battery is empty.

Note: If not using the unit for 3 months, recharge it. Battery may not charge at all under extreme environmental conditions, extreme high heat or cold temperatures.

STEP 1 – CONNECT THE AC ADAPTER TO THE JACK ON THE UNIT

STEP 2 – INSERT THE POWER PLUG INTO AN OUTLET

Note: Do not use another AC adapter other than the one provided.

  • When charging the battery, the battery icon blinks on the screen.

  • When fully charged, the icon will display shortly on the screen, then power off. Press the (power) button to see if the battery is fully charged.
  • Press the  (power) button when the display is off. Then the battery icon appears on the display.

BATTERY ICON

Note: While the battery is charging, the main unit does not work.

Battery life

Rechargeable battery will last for 500 uses when fully charged and under the following conditions: new battery was fully charged, used 1 time/day in normal temperatures of 73.4 °F (23 °C). Battery life depends on usage and storage conditions.
Note: Temperature during battery charging should be cool and dry, +41 to +95 °F (5 to +35 °C).

STEP 3 – UNPLUG THE AC ADAPTER AND POWER PLUG ONCE THE BATTERY IS FULLY CHARGED

ASSEMBLY STEPS

STEP 1 – PREPARE PADS

Put the jack into the bottom left side of the main unit. Place the pads (dark side up) onto a flat surface.

Note: Do not turn the power on before placing the pads on the body.

Before use, inspect the Pad and the cord for open wires or any damage, if damaged, do not use and replace immediately because it could cause skin burns or fire.

STEP 2 – ASSEMBLE GELS

Remove the Gels from the sealed plastic container.
Note: The Pad and the Gel must be used together for safety and effectiveness.
Clean and dry affected area so it’s free of all lotions/oils/sweat.

STORING THE PADS ON THE PAD HOLDER

Remove the plastic film and place the sticky side of the gel on either side of the pad holder.

STEP 3 – PLACE GELS ONTO THE PADS

Each gel has 2 plastic films. Remove the blank plastic film and place it squarely onto the dark side of the pads.
Make sure the gel lays evenly and securely with no bubbles, bending or missing pieces. Check for damage and check the adhesion before each therapy session.
The gel should read “SKIN” on top. Remove the “SKIN” side’s plastic film and place onto the skin.

Note: Do NOT turn unit on until pads with gels are on your skin. You MUST USE BOTH PADS with GELS or stimulation will not work.

STEP 4 – ATTACH THE PADS TO THE BODY

Make sure that pads stick to the skin.

For optimal therapy:

  • Place pads on either side of the pain, not directly on the pain.
  • Place pads at least 1 inch apart.
  • MUST USE TWO PADS at a time for therapy to work.
  • Do not overlap pads or put on top of each other.
  • Do not add spray, lotions or creams to skin or pads.
  • Do not share pads.
  • The pads and gel are not made with natural rubber latex.
NEVER APPLY THE PADS TO THESE BODY AREAS:

GET STARTED WITH YOUR THERAPY

(USE FOR A MAXIMUM OF ONE 30 MINUTES PER SESSION)

STEP 1 – PAD PLACEMENT

Clean and dry affected area so it is free of all lotions/oils/sweat. The PAD with GEL should be applied only to normal, intact, clean, healthy skin that is not experiencing any swelling or inflammation.
Before starting your therapy, rate your pain from 1 low to 10 high. This mental check gives you a basis you can compare to once the session is complete.

LOWER BACK
Attach both pads on the lower back according to your pain. Place pads on muscle of the back, not on spine, for optimal therapy.

Do not use near the heart, on both sides of the chest cavity or across your chest because the introduction of electrical current may cause rhythm disturbances which could be lethal.

STEP 2 – REMEMBER THESE SIMPLE STEPS

COMBO 1 & COMBO 2
1. Pick therapy
2. Pick Heat Setting
3. Pick Mode
4. Adjust Power Level of Intensity (when TENS starts)

TENS Only
1. Pick Therapy
2. Pick Mode
3. Adjust Power Level of Intensity

Note: TO CHANGE THERAPIES, Turn Main Unit OFF, then ON again.

STEP 3 – PICK THE THERAPY

Push (power) button to turn on. Select 1 of 3 therapies using the (up/down) arrow buttons. Next, push SET/START to lock in therapy.

COMBO 1 – Heat 15 min, TENS 15 min
COMBO 2 – Short sessions of HEAT / TENS/ HEAT / TENS alternating for 30 min.
TENS – Electrical Stimulation only for 30 min.

Note: All therapies automatically stop after 30 minutes.
TO CHANGE THERAPIES,
Turn Main Unit OFF, then ON again.

Three Therapies Available

STEP 4 – PICK HEAT SETTING

Select HEAT HI or LOW using the (left/right) arrow buttons. Next, push SET/START to lock in heat setting.

Note: Heat setting applies only to COMBO 1/COMBO 2 Therapies.

Note: Low temperature – 107 °F (42 °C)
Hi temperature – 110 °F (43 °C)
Actual temperature may vary due to skin condition, age, location of pain and more.

STEP 5 – PICK 1 OF 9 MODES

Select MODE by pushing the SET/START button. To CHANGE MODES, MODES, use the (up/down) and (left/right) arrow buttons.

Note: COMBO 1 & COMBO 2 therapies begin with “HEAT” and you will see a RED GLOW. When TENS is in use the RED GLOW will disappear.

How to switch modes
The unit automatically defaults to the last mode selected. Push SET/START button to switch modes. Use (up/down) and (left/right) arrow buttons to move from mode to mode. Push SET/START to lock in the mode.

How to select the right mode
Any of the modes can be used on body parts or pains described in this manual or Quick Start Guide/Pad Placement Guide. Select the mode that feels comfortable for your unique pain.

Note: See side of device for easy reference of operation.

STEP 6 – ADJUST THE LEVEL OF INTENSITY (1 LOW – 20 HIGH)

Start at the lowest intensity level and slowly increase it by pushing the (up) or (right) arrow button). You should feel a gentle pulsing sensation.
When the main unit is in “TENS” stimulation, you can adjust the power level of intensity. Use any of the arrow buttons to CHANGE THE POWER LEVEL OF INTENSITY.

How do I pick the right intensity level for my pain?

Each time you press the (up) or (right) or  (down)  or  (left) arrow button, it moves to another level. If the stimulation sensation becomes weaker or disappears, increase the intensity until it is restored. But, if the sensation is at all uncomfortable, press the (down) or  (left) arrow button to decrease the intensity.

  • Press the  (up) or (right) arrow button for higher intensity.
  • Press the  (down)  or  (left) arrow button for lower intensity.
How long is the therapy?

The unit will operate automatically for 30 minutes before it shuts off. We recommend a maximum of one 30 minute therapy in one sitting, up to 3 times/day.
The screen shows you how many minutes are remaining.

HOW TO CONTROL AND REDUCE YOUR PAIN

When should I start therapy?

Use as soon as your pain begins. Start with 1 session (the unit automatically turns off at 30 minutes). Turn off with pads still on and RATE YOUR PAIN again (1 low to 10 high).

Get to your pain early

If you get to your pain early, it may prevent the pain from becoming worse, or even chronic. It’s better for you to get it under control sooner so that it does not reach a high pain threshold where it limits your daily activities.

How long should you use it?

Start with one 30 minute session. Always turn the unit off with pads still on. Rate your pain to check your progress, 1 low to 10 high. Stop therapy session if pain has reduced or stopped.

See precautions on page 8. Long-time treatment and strong stimulation may cause muscular fatigue and may generate adverse effects.

When to stop using the unit?

  1. If you experienced an adverse reaction (skin irritation/redness/burns, headache or other painful sensation, or if you feel any unusual discomfort).
  2. If your pain does not improve, becomes seriously chronic and severe, or continues for more than 5 days.
    Remember, the unit does not cure your pain or the original cause of the pain. It provides temporary relief or reduction of pain so that you can control your life and activities better.

CLEANING AND STORAGE

The Cord with Pads, and the Main Unit are permanent and CAN BE CLEANED, but you cannot clean the Gels.

Cleaning the main unit and the cord with permanent pads

  1. Remove the Gel and discard before cleaning the Pad.
  2. When the Pad or Main Unit have become dirty or soiled, wipe the surface with a soft cloth moistened with water or a neutral detergent.
    • Do not get the Main Unit or cord with pads wet.
    • Do not wash the pads with running water.
  3. Let air dry before placing new Gels onto the Pads, do not use old gels.
  4. Gels are replaceable and can be purchased when needed by calling 1-800-634-4350 or go to OmronHealthcare.com.

Cleaning the unit

  1. Turn the unit off and disconnect the cord with pads from the unit.
  2. Clean with a lightly moistened cloth (or a cloth soaked in a neutral cleaning solution) and wipe gently.
    • Do not use chemicals (like thinner, benzene).
    • Do not let water get into the internal area.

When should you replace your gels?

If the gel no longer sticks firmly to your skin, or if more that 25% of the gel is not in contact with your skin, replace the Gel.

Storing the pads with gels

  1. Turn the unit off and remove the cord from the bottom of the unit.
  2. Remove the pads from your body.
  3. Leave the cord connected to the pads.
    Place the pads on the pad holder, 1 pad on each side with the sticky side of each pad on the pad holder.
  4. Wrap the pads with gels cord around the pad holder.

Storing the main unit and the pads with gels

  • Do not keep in areas subject to direct sunlight, high or low temperatures, humid area, near to fire, vibration, or shock.
  • Try not to bend or fold the cord with pads and gels during therapy or during storage.

Storage temperature
+32 to +104 °F (0 to +40 °C) 30 to 80 % relative humidity.

  • Do not keep at places that can be easily reached by children.
  • Do not wrap the cord around the unit because it may damage the cord.

For information about how to dispose of the used battery and unit

  • Consult the guidelines of your city, county or state.

TROUBLESHOOTING

If the above measures are not effective, contact us at 1-800-634-4350.

SPECIFICATIONS/SYMBOLS

FCC STATEMENT

FCC CAUTION

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

IMPORTANT INFORMATION REGARDING ELECTRO MAGNETIC COMPATIBILITY (EMC)

With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation.

Medical devices should also not interfere with other devices.

In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the IEC60601-1-2 standard has been implemented. This standard defines the levels of immunity to electromagnetic emissions for medical devices.

Medical devices manufactured for OMRON Healthcare conform to this IEC60601-1-2:2007 standard for both immunity and emissions.

Nevertheless, special precautions need to be observed:

  • The use of accessories and cables other than those specified by OMRON, with the exception of cables sold by OMRON as replacement parts for internal components, may result in increased emission or decreased immunity of the device.
  • The medical devices should not be used adjacent to or stacked with other equipment. In case adjacent or stacked use is necessary, the medical device should be observed to verify normal operation in the configuration in which it will be used.
  • Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter. During the immunity tests described below the device operated normally.

The PM311 is intended for use in the electromagnetic environment specified below. The customer or the user of the PM311 should assure that it is used in such environment.