Airsense 10 Cpap Machine Resmed
Thank you for choosing the ResMed serial adapter.
Intended use
Used with ResMed devices during sleep studies, the serial adapter transmits patient therapy data between the Air10 device and compatible Portable Diagnostic Systems (PDS) Bluetooth adapters.
The Air10 serial adapter shown in illustration A is compatible with AirSense™ 10 /AirCurve™ 10 / Lumis™ VPAP 100 / Lumis™ VPAP 150 devices.
The serial adapter is intended for home and hospital use.
Before using the serial adapter, read the entire guide together with the device User Guide.
Note: Not all devices are available in all regions.
Serial adapter at a glance
The serial adapter comprises the following elements:
- serial adapter
- serial adapter cable.
Air10 serial adapter
Refer to illustration A:
- Adapter connector.
- Release button.
- Serial adapter cable connector port.
AirSense 10 / AirCurve 10 / Lumis VPAP 100 / Lumis VPAP 150
Refer to illustration B:
- SD card cover.
- Air filter cover.
- Adapter cover.
- Adapter port.
Setting up
See illustration C:
- Ensure the device is disconnected from the power outlet.
- Connect the serial adapter to the device.
- Connect one end of the serial adapter cable to the serial adapter and the other to the PDS. Refer to the PDS user instructions for information on setup and use.
- Reconnect the device to the power outlet.
You can now perform sleep studies. When the sleep studies or data download are complete, you can remove the serial adapter.
Note:
- To reduce interference with Bluetooth communications, we recommend placing the Air10 device in Airplane Mode (if available) when using the Air10 Serial adapter with PDS systems that utilize Bluetooth connections.
- If you need help or to report an unexpected issue, contact a ResMed representative, ResMed Technical Services or see www.resmed.com.
Removing the serial adapter
- Disconnect the device from the power outlet.
- Press the release button/s on the side of the serial adapter and pull gently to remove it from the device.
Cleaning and maintenance
- Disconnect the device from the power outlet and remove the serial adapter.
- Wipe the exterior of the serial adapter with a clean, dry cloth. The contacts do not require cleaning.
Technical specifications
Operating temperature | +41°F to +95°F (+5°C to +35°C) |
Operating humidity | 10 to 95% non-condensing |
Operating altitude | Refer to your device User Guide for details. |
Storage and transport temperature | -4°F to 140°F (-20°C to +60°C) |
Storage and transport humidity | 5 to 95% non-condensing |
Design life | 1,825 connections |
Gross dimensions (W x D x H) | 2.1″ x 1.2″ x 2.0″ (54 mm x 30 mm x 51 mm) |
Weight | 0.88 oz (25 g) |
Electromagnetic compatibility | Refer to your device User Guide for details. |
Note: The manufacturer reserves the right to change these specifications without notice.
Symbols
The following symbols may appear on the serial adapter or packaging:
Caution/ Warning. | |
Read instructions before use. | |
Manufacturer | |
European Authorized Representative. | |
Batch code. | |
Catalog number. | |
Serial number. | |
Protected against finger sized objects and against dripping water when tilted up to 15 degrees from specified orientation. | |
Humidity limitation. | |
Temperature limitation. | |
European RoHS. | |
China pollution control logo. | |
Canadian Standards Association. | |
Importer. | |
Medical device. | |
Prescription only (In the US, Federal law restricts these devices to sale by or on the order of a physician). |
Environmental information
This device should be disposed of separately, not as unsorted municipal waste.
To dispose of your device, you should use appropriate collection, reuse and recycling systems available in your region. The use of these collection, reuse and recycling systems is designed to reduce pressure on natural resources and prevent hazardous substances from damaging the environment.
If you need information on these disposal systems, please contact your local waste administration. The crossed-bin symbol invites you to use these disposal systems. If you require information on collection and disposal of your ResMed device please contact your ResMed office, local distributor or go to www.resmed.com/environment.
WARNING
Do not open or modify the serial adapter. The serial adapter is not designed to be serviced. There are no serviceable parts inside.
CAUTION
- In the US, Federal law restricts this device to sale by or on the order of a physician.
- Only use the serial adapter as specified in this guide.
- Air10 serial adapters are specifically designed for use with ResMed AirSense 10 /AirCurve 10 / Lumis VPAP 100 / Lumis VPAP 150 devices.
- Do not use liquids to clean any part of the serial adapter
Note: Any serious incident that has occured in relation to this device should be reported to ResMed and to the competent authority in your country
Limited warranty
Please refer to your device User Guide.
ResMed Pty Ltd
1 Elizabeth Macarthur Drive
Bella Vista NSW 2153 Australia
See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip.
Air10, AirCurve, AirSense, AirView, Lumis and ResScan are trademarks of ResMed.
© 2022 ResMed. 3781044/1 2022-02