Loading manuals...

Honeywell RTH5160D1003 thermostat Manual


Honeywell RTH5160D1003 thermostat Manual Image

The Honeywell RTH5160 Non-Programmable Thermostat Installation and Instruction Manual is a comprehensive guide to installing and setting up your thermostat. This manual provides step-by-step instructions for removing your old thermostat and installing the new one. It also includes information on the tools you will need, how to bundle and insert wires through the UWP, how to set R-switch position and insert R-wire(s), and how to confirm wiring matches snapshot. The manual also provides information on system setup options, system operation settings, fan operation settings, and wiring for conventional systems and heat pumps. Additionally, the manual includes instructions for battery replacement, alerts screen, alerts codes, troubleshooting, and a 1-year limited warranty. The Honeywell RTH5160 Non-Programmable Thermostat is a reliable and easy-to-use thermostat that is perfect for those who want a simple solution for controlling their heating and cooling systems.

Honeywell RTH5160 Non-Programmable Thermostat

View all Honeywell thermostat manual

Other Honeywell Pro Thermostat Manuals:

  • T4 Pro
  • T6 Pro
  • RTH5160 Non-Programmable Thermostat
  • WiFi Touchscreen Thermostat Installation Manual
  • WiFi Color Touchscreen Thermostat
  • VisionPRO WiFi Thermostat

Tools you will need

Tools you may need

Removing your old thermostat

  1. Turn power OFF.

To protect yourself and your equipment, turn off the power at the breaker box or the switch that
controls your heating/cooling system.

2. Check that your system is off.
Change the temperature on your old thermostat to be above room temperature in heat mode or below it in cool mode. If you don’t hear the system turn on within 5 minutes, the power is off.

Note: If you have a digital thermostat that has a blank display, skip this step.

3. Remove the old thermostat’s faceplate.
On most thermostats, you can take off the faceplate by grasping and gently pulling. Some thermostats may have screws, buttons, or clasps.

Caution: Do not remove any wires from your thermostat at this time!

4. Make sure there are no 120/240V wires.

Caution:

  • Do you have thick black wires with wire nuts?
  • Is your thermostat 120V or higher?
    If you answered yes to either of these questions, you have a line voltage system and the thermostat will not work.

5. Take a picture of how your wiring looks right now.
Be sure to include the letters next to the terminals where the wires are inserted. This will be a helpful reference when wiring your new thermostat.

Tip: If the color of your wires has faded or if 2 terminals have the same wire color, use the wire labels provided in the package to label each wire.

6. Record which R-wire(s) you have and write down the color of the wire(s).

Note: Do not include jumpers as a part of your count. The thermostat does not need jumpers.

7.  Record the remaining wires and write down the color of the wires.
Check mark the wires that are connected to terminals. Next to the check mark, write down the color of the wire. Do not include jumpers as a part of your count.

Check all that apply (Not all will apply):

Fig 7 Record the remaining wires

NOTES:

  • C does not power the thermostat display or operations; batteries are always required.
  • If K was used on old thermostat you have a wire-saver at the equipment.
    Re-wiring would need to be done so that Y and G are used instead of K.
  • The RTH5160 thermostat does not support L/A, S, or U terminals.
  • If there are wires in terminals that are not listed, you will need additional wiring support. Visit yourhome.honeywell.com/support to find out if the thermostat will work for you.

8. Disconnect the wires and remove the old wall plate.
Use a screwdriver to release wires from terminals. Then, use a wire label to identify each wire as it’s disconnected. The letter on the wire label should match the letter on the terminal.

Tip: To prevent wires from falling back into the wall, wrap the wires around a pencil.

Installing your RTH5160 thermostat

9. Bundle and insert wires through the UWP.
Pull open the UWP and insert the bundle of wires through the back of the UWP.

Make sure at least 1/4 inch of each wire is exposed for easy insertion into the wire terminals.

10. Insert the wall anchors.
It is recommended that you use the wall anchors included in the box to mount your thermostat.

You can use the UWP to mark where you want to place the wall anchors.

  • Level the wall plate.
  •  Mark the location of the wall anchors using a pencil.
  • Drill the holes.
  • Insert wall anchors.
  • Make sure anchors are flush with wall.

Tip: Use a 7/32 drill bit.

11. Set R-switch position and insert R-wire(s).
Set the R-switch up or down based on your wiring notes in Step 6.

Caution: Insert wires into the inner holes of the terminals on the UWP. The tabs will
stay down once the wire is inserted.

NOTE: Alternate wiring options are shown on pages 11-12.

If you have 1 R-wire (R, Rh, or Rc)

12. Connect remaining wires.
Depress the tabs to put the wires into the inner holes of the corresponding terminals on the UWP (one wire per terminal) until it is firmly in place.

Gently tug on the wires to verify they are secure.

Tip: If you need to release a wire again, push down the corresponding terminal tab on the side of the UWP.
NOTE: Alternate wiring options are shown on pages 11-12.

13. Confirm wiring matches snapshot.
Please confirm wiring matches terminals from the photo you took in Step 5.

14. Mount the UWP and close the door.
Mount the UWP using the provided screws. Install all three screws for a secure fit on your wall. Close the door after you’re finished.

15. Install batteries.
Insert two AA alkaline batteries in the back of the thermostat as shown.

16. Attach your thermostat.
Align the thermostat onto the UWP and firmly snap it into place.

17. Turn your power ON.
Turn on the power at the breaker box or switch that controls the heating/ cooling system.

System Setup

Now that you have installed your thermostat, please follow the steps below to setup your system and personalize your thermostat.

18.  Select System Setup options.

  • Press Edit (-) to change values or select from available options. Then press Next (+) to save changes and advance to the next System Setup number. See “System Setup options” on the next page for a full list of System Setup numbers and options.
  • Repeat until all of the System Setup options have been set, and then press
  • Done. The thermostat will save and exit to the home screen.

19. Continue to “System operation settings” on page 10.

NOTE: To re-enter the System Setup from the Home Screen, press and hold the Menu button for approximately 5 seconds.

System Setup options

NOTE: Once you have cycled through all of the System Setup numbers, press Done to save and exit to the home screen.

Setup Complete
You have now finished installing and setting up your thermostat.

System operation settings

  1. Press Menu, and then press the Mode (+) button to cycle to the next available System mode.
  2. Cycle through the modes until the required System mode is displayed, and then press Done.

NOTE: Available System modes vary by model and system settings.

System modes:

  • Auto: Thermostat selects heating or cooling as needed.
  • Heat: Thermostat controls only the heating system.
  • Cool: Thermostat controls only the cooling system.
  • Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Auxiliary Heat. Compressor is not used.
  • Off: Heating and cooling system is off. Fan will still operate if fan is set to On.

NOTE: Heat On/Cool On may flash for 5 minutes due to compressor protection.

Fan operation settings

  1. Press Menu, and then press the Fan (-) button to cycle to the next available Fan mode.
  2. Cycle through the modes until the required Fan mode is displayed, then press Done.

NOTE: Available Fan modes vary with system settings.

Fan modes:

  • Auto: Fan runs only when the heating or cooling system is on.
  • On: Fan is always on.

Wiring—conventional systems

Alternate wiring (conventional systems)
If labels do not match terminals, connect wires as shown below (see notes, below).

NOTES:

  • If you must connect both R and Rc wires, set the R Slider Tab to the down position (2 wires).
  • If your old thermostat had both R and RH wires, set the R Slider Tab to the down position (2 wires). Then connect the R wire to the Rc terminal, and the RH wire to the R terminal.
  • If your old thermostat had only 1 C or C1 wire, connect it to the C terminal. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not connect them.
  • C does not power the thermostat display or operations; batteries are always required.

Wiring—heat pump

Connect wires: heat pump

  • Match each labeled wire with same letter on new thermostat.
  • Insert the wires into the matching terminal.

NOTE: If you have difficulty inserting wires, you may have to press down the terminal push button next to the corresponding terminal.

Labels don’t match?
If labels do not match letters on thermostat, see “Alternate wiring (conventional systems)“ above.

Alternate wiring (for heat pumps only)

  • Keep R Slider Tab in the up position (1 wire).
  • If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help.
  • If your old thermostat had separate O and B wires, attach the B wire to the C terminal. If another wire is attached to the C terminal, stop now and contact a qualified contractor for help.
  • If your old thermostat had Y1, W1 and W2 wires, stop now and contact a qualified contractor for help.
  • C does not power the thermostat display or operations; batteries are always
    required.
  • This model doesn’t support the heat pump fault alert (L/A terminal). If this
    is desired, please contact a contractor for replacement model.

Battery Replacement

Batteries are required to provide power. Install fresh batteries immediately when the low battery icon appears. The icon appears about two months before the batteries are depleted.

Even if the low battery icon does not appear, you should replace batteries once a year, or before leaving home for more than a month.

If batteries are inserted within two minutes, the time and day will not have to be reset. All other settings are permanently stored in memory, and do not require battery power.

NOTE: When replacing batteries, alkaline batteries are recommended.

Alerts Screen

  • You will see the alert icon  and the alert number on the screen.

  • Press Next (+) to see additional alerts, if any. Then press Done to go back to the home screen.

NOTE: If the alert is a critical alert, you may not be able to access the home screen and should call a HVAC professional.

Alerts Codes

Troubleshooting

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

  • Display is blank : Make sure fresh AA alkaline batteries are properly installed (see page 7).
  • Cannot change system setting to Cool:  Check System Setup Option 220 to make sure the options are set to either 1 or 2 (see page 9).
  • Fan does not turn on when heat is required: Check System Setup Option 205 to make sure it is set to match your heating equipment (see page 9).
  • Heating system is running in cool mode:  Check System Setup Option 200 or 218 to make sure it is set to match your heating and cooling equipment (see see page 9).
  • Heating or cooling system does not respond:
    Press Menu and then Mode to set system to Heat. Make sure the temperature is set higher than the Inside temperature. Press Menu and then Mode to set system to Cool. Make sure the temperature is set lower than the Inside temperature. Check circuit breaker and reset if necessary. Make sure power switch at heating & cooling system is on. Make sure furnace door is closed securely. Wait 5 minutes for the system to respond.
  • Heat On / Cool On flashing on the screen: Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.
  • Heat pump issues cool air in heat mode, or warm air in cool mode:  Check System Setup Option 200 or 218 to make sure it is set to match your heating and cooling equipment (see page 9).

1-year limited warranty

Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option). If the product is defective,

  • Return it, with a bill of sale or other dated proof of purchase, to the place from
    which you purchased it; or
  • Call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following
    address: Honeywell Return Goods, Dock 4 MN10-3860, 1985 Douglas Dr. N.,
    Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above.

HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING
THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS
WARRANTY.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state.

If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800- 468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/ Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V4Z9.

CAUTION: ELECTRICAL HAZARD                                                                 Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

CAUTION: MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

ALERT: HHW PROPER DISPOSAL
This product is an electronic device and considered Household Hazardous Waste (HHW). It should not be disposed of with other household waste. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Video

SPECIFICATIONS

Product Name Honeywell RTH5160 Non-Programmable Thermostat
Manual Type Installation & Instruction Guide
Installation Instructions Step-by-step instructions for removing old thermostat and installing new one, including information on tools needed, wiring, and system setup options
System Setup Options Auto, Heat, Cool, Em Heat, Off
Fan Operation Settings Auto, On
Wiring Compatibility Conventional systems and heat pumps
Battery Type AA alkaline batteries
Alerts Alerts screen, alerts codes, and troubleshooting instructions
Warranty 1-year limited warranty

FAQs

Do I have a line voltage system?

No, I don’t have a line voltage system. I’m using the Honeywell RTH5160 Non-Programmable Thermostat.

Will this work if I only have a two wire system? I only have one red and one white wire since my heating system is just a fan pretty much.

YES! put the red on R and put the White wire under (w) on it – I just installed this and going to purchase another!

Can anyone confirm please that this works with radiant (hydronic/hydrant/water) heating?

The Honeywell RTH5160D Digital Non-Programmable Thermostat is designed to work with standard low voltage systems, including radiant heating (Boiler) systems. If you have additional concerns or questions, feel free to contact us at 1-855-733-5465, or through live chat at http://www.honeywellhome.com/en/support; hours for both are from 8 AM to 10 PM CST Monday through Sunday. You can also reach us via Twitter or Facebook from 7 AM to 7 PM CST Monday through Sunday.

Does this work on multi stage furnaces?

Yes

Will this work with comfortbridgetm technology?

the Honeywell Home RTH5160D1003 Non-programmable Thermostat is designed to work with most 24V systems. To determine if this thermostat is compatible with your system, we recommend reaching out to the equipment manufacture.

My old thermostat has rc and rh with a jumper. this thermostat does not sepearte the two. do i just connect the red wire to the r on this new one?

Yes

Is this compatible with a forced air system?

This should be compatible with a forced air system. I have a heat pump and are coming out is forced air and it works perfectly.

Will this thermostat work on our Air conditioner that doesn’t have a heat pump. We have a heat strip.

This thermostat will work on a central air conditioning/heating system.

will this work on a 5 wire system, i have 5 wires coming out of the wall going to my current thermostat

My system was two wires, red and white. The instruction manual has directions for all types of connections.

Anybody else have problems with the ambient air reading being off? 

no

Can i use this with riello start 24? i have 2 cords coming out of it, which use 220 volts to signal the boiler to start/stop.

This thermostat is only for use in a low voltage system. Connecting a 220 volt source will blow it out and trip a circuit breaker. It would be dangerous.

How large are the numbers?

Large bold numbers (room temp) are 1/2 W X 13/16 H. Smaller numbers (set temp) are 11/32 H. Very readable and back light illuminates for several seconds when button depressed. Love this thermostat. Use it to control my pellet stove.

What is the swing temp for this thermostat?

Swing temp? Mine stays where set and doesn’t even move a single degree. Very precise. I also set auto 2 degrees apart and will still switch between ac and heat.

Would you tell me how big the display screen is?

the display screen isn’t much larger than 3×3. Please reach out to our support team on Facebook/Twitter with a private message if you have any further questions. We look forward to hearing from you soon.

IS their any Emergency heat option?

the thermostat has an option for Em heat (only for heat pumps with auxiliary heat). For further information and compatibility data, please contact our technical support team at 1-800-468-1502. We’ll be glad to assist you.

What tools are needed for installation of the Honeywell RTH5160 thermostat?

The manual lists the tools needed as a screwdriver, drill, and 7/32 drill bit.

How do I remove my old thermostat?

First, turn off the power at the breaker box or switch that controls your heating/cooling system. Then, remove the old thermostat’s faceplate and take a picture of how your wiring looks right now. Disconnect the wires and remove the old wall plate.

How do I install my RTH5160 thermostat?

Bundle and insert wires through the UWP, insert the wall anchors, set R-switch position and insert R-wire(s), connect remaining wires, confirm wiring matches snapshot, mount the UWP and close the door, install batteries, and attach your thermostat.

What are the available system modes for the Honeywell RTH5160 thermostat?

The available system modes are Auto (thermostat selects heating or cooling as needed), Heat (thermostat controls only the heating system), Cool (thermostat controls only the cooling system), Em Heat (only for heat pumps with auxiliary heat; thermostat controls Auxiliary Heat. Compressor is not used), and Off (heating and cooling system is off. Fan will still operate if fan is set to On).

What are the available fan modes for the Honeywell RTH5160 thermostat?

The available fan modes are Auto (fan runs only when the heating or cooling system is on) and On (fan is always on).

What do I do if my labels don’t match when wiring my conventional system?

If labels do not match terminals, connect wires as shown in the “Alternate wiring (conventional systems)” section of the manual.

What do I do if my labels don’t match when wiring my heat pump?

If labels do not match letters on thermostat, see the “Alternate wiring (for heat pumps only)” section of the manual.

What should I do if I need additional wiring support?

Visit yourhome.honeywell.com/support to find out if the thermostat will work for you.

How do I replace the batteries in my Honeywell RTH5160 thermostat?

When replacing batteries, alkaline batteries are recommended.

Does the Honeywell RTH5160 thermostat have a heat pump fault alert?

This model doesn’t support the heat pump fault alert (L/A terminal). If this is desired, please contact a contractor for replacement model.

Will this work with a millivolt gas fireplace?

Furnace systems are generally designed around standard 28v power. They do not appear to be compatible.

Shouldn’t this thermostat last longer, than a year?

Yes, absolutely. Now the battery won’t, but that is easy to change yourself. This type f thermostat is a set it and forget it variety.

Customer Assistance

For assistance with this product, please visit
http://yourhome.honeywell.com.
Or call Honeywell Customer Care
toll-free at 1-800-468-1502.

Home and Building Technologies
In the U.S.:
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422-3992
customer.honeywell.com

® U.S. Registered Trademark.
© 2017 Honeywell International Inc.
33-00200EF—01 M.S. 08-17
Printed in U.S.A.


More Manuals From Honeywell