Loading manuals...

SALUS RT510 Programmable Room Thermostat manual


SALUS RT510 Programmable Room Thermostat manual Image

Model: RT510 (Wired, electronic thermostat – programmable)
RT510RF (Wireless, electronic thermostat – programmable)

Installation Manual

Introduction

RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allow us to use various operating modes – automatic (time schedules), manual, frost protection, or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.

Product compliance

Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU, and RoHS 2011/65/EU.
Full information is available on the website www.saluslegal.com

Safety Information

Use in accordance with national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.

Technical specification

RT510 Thermostat RT510TX Thermostat
Thermostat supply 2x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A
Outputs Voltage free NO / COM / NC terminals
Temperature range 5 – 35°C 5 – 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Control algorithm TN or hysteresis ±0.25°C TPI or hysteresis ±0.25°C
Radiofrequency 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radiofrequency 868 MHz
Dimension [mm] 96x96x27

Button functions

1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode,
OFF will turn the boiler off.
8. Receiver operates in automatic mode according to the thermostat
9. Receiver output is controlled by the On/Off slide switch.

LCD Icon description

1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock

RT510 Terminals description

Terminal Description
1 – COM Common Terminal
2 – NC Switched Live OFF
3 – NO Switched Live ON

RXRT510 Receiver terminals description

Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)

DIP Switch Settings

Control feature TPI Span
Operation When TPI is selected on DIP switch № 2, the  IP
switch № 1 is functional.
You can choose the Cycles Per Hour between a lower comfort level (6CPH) and a higher comfort level (9CPH).
When Span is selected on DIP switch № 2, the DIP switch № 1 is not functional.  The thespian value is set to ± 0.25°C – it is recommended to use with heating devices.

RT510 Wiring diagram

RT510RF Wiring diagram

Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.

Setting the time

Programming – automatic mode

In this mode, the user can set the schedules for the thermostat (temperature setpoints for a specific period of time). You have the option to choose between a 5-2 days program or a daily one by using the parameter d04 from Installer mode. Programmed schedules should use all time periods.

Temporary Override mode

This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule – it will be maintained until the next time interval tarts according to a programmed schedule.

Temporary Override mode will be disabled when a new schedule will be set.

Manual Mode and setting setpoint temperature

In this mode, the thermostat does not work according to the programmed schedule but it will maintain the selected temperature.

Press button to activate the Manual Mode.

To turn off the Manual Mode press button. Once the manual mode is off, the hand icon on the thermostat will disappear.

Hourly temperature Override Mode (+Hr)

This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, the thermostat returns to the previous model.

Turning off hourly temperature override mode before time’s up

Frost Protection

The temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed in Installer Mode in the d03 parameter.

Turning Off the Frost Protection mode

Sleep mode

When the sleep mode is activated, all thermostat functions are paused.

Holiday Mode

In this mode, the “frost protection” temperature is maintained for a specific number of days.

To turn off the Holiday Mode, hold the downbutton for 3 seconds. The airplane icon should disappear from the display.

RT510TX thermostat pairing with the receiver

Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
If you want to re-pair the thermostat with the receiver, make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for the red LED to light steadily. Next switch to the OFF position and again to the ON position quickly. The red flashing LED will confirm entering the pairing mode.
Begin the pairing process

End the pairing process

Once devices are successfully paired, the LED on the receiver will go solid red.
Press and hold the TEST / PAIRING button for 3 seconds to end the pairing process.
Test the pairing process

If you purchased an RXRT510 or RT510TX and intend pairing with other devices in the 5×5 range, please refer to the Receiver Units manual or the relevant manuals available at www.salus-controls.eu

Installer mode

dxx Function Parametr value
d01 Temperature display increments 0.1°C or 0.5°C 0.5°C
d02 Temperature offset +/- 3.0°C 0.0°C
d03 Frost Protection setpoint temperature 5.0°C – 17.0°C 5.0°C
d04 Programmer selection 5/2 or 24 hr (7d) 52 d

Reset of the RT510 thermostat

Press the RESET button once. You can use a paper clip. Your thermostat will be reset and will start up automatically.

Reset of the RT510TX thermostat

Remove the batteries without pressing any button.
Wait 2 minutes and insert the batteries again.
Your device will be restarted.
When you want to change the batteries your device will use the internal memory to backup your settings. You have 30 seconds to change the batteries before losing your
settings.

DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland
Importer:
SALUS Controls Plc
Units 8-10 Northfield Business Park
Forge Way, Parkgate, Rotherham
S60 1SD, United Kingdom

www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
VI 2020



More Manuals From SALUS